US$3494.00 · In stock Delivery: <= 10 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 13539.2-2015: Low-voltage fuses -- Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) -- Examples of standardized systems of fuses A to K Status: Valid GB/T 13539.2: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 13539.2-2015 | English | 3494 |
Add to Cart
|
10 days [Need to translate]
|
Low-voltage fuses -- Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) -- Examples of standardized systems of fuses A to K
| Valid |
GB/T 13539.2-2015
|
| GB/T 13539.2-2008 | English | RFQ |
ASK
|
10 days [Need to translate]
|
Low-voltage fuses -- Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) -- Examples of standardized systems of fuses A to I
| Obsolete |
GB/T 13539.2-2008
|
| GB/T 13539.2-2002 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
Low-voltage fuses -- Part 2: the use of full-time staff fuses Supplementary requirements (mainly for industrial fuses)
| Obsolete |
GB/T 13539.2-2002
|
| GB 13539.2-1992 | English | RFQ |
ASK
|
9 days [Need to translate]
|
Low-voltage fuses Supplementary requirements for fuses for use by authoriaed persons
| Obsolete |
GB 13539.2-1992
|
PDF similar to GB/T 13539.2-2015
Basic data | Standard ID | GB/T 13539.2-2015 (GB/T13539.2-2015) | | Description (Translated English) | Low-voltage fuses -- Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) -- Examples of standardized systems of fuses A to K | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K31 | | Classification of International Standard | 29.120.50 | | Word Count Estimation | 175,143 | | Date of Issue | 2015-09-11 | | Date of Implementation | 2016-04-01 | | Older Standard (superseded by this standard) | GB/T 13539.2-2008 | | Quoted Standard | GB/T 4207-2012; GB 13539.1-2015; GB/T 16935.1-2008; IEC 60999; GB 17464-2012; GB/T 20636-2006; GB/T 9789-2008 | | Adopted Standard | IEC 60269-2-2013, IDT | | Regulation (derived from) | National Standard Announcement 2015 No.25 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the following fuse systems, each system involves a specific example of a standard fuse full-time staff to use. |
GB/T 13539.2-2015: Low-voltage fuses -- Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) -- Examples of standardized systems of fuses A to K
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Low-voltage fuses - Part 2. Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K
ICS 29.120.50
K31
National Standards of People's Republic of China
Replacing GB/T 13539.2-2008
Low-voltage fuses
Part 2. fuses for use by full-time staff
Supplementary requirements (mainly for industrial fuses)
Examples of standardized systems of fuses A to K
Low-voltagefuses-
Part 2. Supplementaryrequirementsforfusesforusebyauthorized
persons (fusesmainlyforindustrialapplication) -
(IEC 60269-2.2013, IDT)
Issued on. 2016-04-01 2015-09-11 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 1 Total range
2 Normative references 1
Fuse Systems A --- knife type contact fuse (NH fuse system) 3
Special tests Annex AA (informative) cable overload protection 38
Fuse system B --- with striker knife type contact fuse (NH fuse system) 39
Fuse system C --- bar fuse bases (NH fuse system) 50
Fuse system D --- Bus installation (40mm system) fuse-bases (NH fuse system) 59
Fuse system E --- bolted fuse (BS bolted fuse system) 70
Fuse system F --- cylindrical cap fuse (NF cylindrical cap fuse system) 83
Fuse system G --- bias contact blade fuse (BS fuses clamping system) 95
Fuse system H --- "gD" and "gN" characteristic Fuse (J type, T type and class L time delay and non-delay fuse type) 105
Fuse system I --- gU wedge-shaped contact fuse 128
Fuse system J --- "CC class gD" and "CC class gN" characteristic Fuse (CC class delay and non-delay fuse type) 141
Fuse Systems K --- knife type contact fuse bolted gK (from 1250A to 4800A high current rating
Main fuse) 156
References 169
Foreword
GB 13539 "Low-voltage fuses" currently consists of the following six sections.
--- Part 1. General requirements;
--- Part 2. Supplementary requirements for full-time personnel fuses (fuses mainly for industrial application) standardized systems of fuses
Example A through K;
--- Part 3. fuses for use by unskilled persons Supplementary requirements (fuses mainly for household and similar purposes) standard
Example of fuse system A to F;
--- Part 4. Supplementary requirements for protection of semiconductor devices fuse body;
--- Part 5. low voltage fuse Application Guide;
--- Part 6. solar photovoltaic system protection Supplementary requirements for fuse.
This is Part 2 GB 13539's.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This Part replaces GB/T 13539.2-2008 "Low-voltage fuses - Part 2. full-time staff Supplementary requirements for fuses for use (primary
To be used for industrial fuses) Examples of standardized fuses A to I ". This portion of the GB/T 13539.2-2008 main changes
as follows.
--- Fuse Systems A modified fuse power dissipation, increasing the fuse size r, size 000 technical parameters and the insulating portion
Member proof tracking specific requirements;
--- Fuse system B modified fuse power dissipation and increases the fuse size r;
--- Fuse Systems C increases the heat resistance verification clause 8.9 and D-type fuse base bar diagram;
--- Fuse system F modified fuse rated current, power dissipation and the rated breaking capacity;
--- Fuse system B, D ~ increased 7.2 terms, clearly overvoltage category requirements;
--- Fuse Systems Class T fuses H increases;
--- Increased knife contact Fuse Systems J "CC class gD" and "CC class gN" characteristic Fuses and bolting systems K
Head gK fuse.
This section uses the translation method is equivalent to using IEC 60269-2. Fuse used full-time staff. the 2013 "low-voltage fuses - Part 2
Supplementary requirements (mainly for industrial fuses) standardized systems of fuses A to sample K ".
The correspondence between the consistency of the international normative documents referenced in our country with the following documents.
--- GB/T 4207-2012 solid insulating materials resistance to tracking index measurement method and comparative tracking index (IEC 60112.
2009, IDT);
Sulfur dioxide test --- GB/T 9789-2008 Metallic and other inorganic coatings general condensation
(ISO 6988. 1985, IDT);
--- GB 13539.1-2015 Low-voltage fuses - Part 1. General requirements (IEC 60269-1.2009, IDT);
--- Insulation coordination GB/T 16935.1-2008 within the low-pressure system equipment - Part 1. Principles, requirements and tests
(IEC 60664-1.2007, IDT);
--- GB 17464-2012 Connecting devices - Electrical copper conductors screw-type and screwless type clamping safety requirements apply to
0.2mm2 or more to 35mm2 (including) the general requirements of the wire clamp and special requirements (IEC 60999-1.1999,
IDT);
--- GB/T 20636-2006 Connecting devices - Electrical copper wire threaded and non-threaded type clamping safety requirements apply
35mm2 to 300mm2 or more to the special requirements of wire (IEC 60999-2.2003, IDT).
This part made the following editorial changes.
Note in the original "National Committees may be selected from the above example --- one or more of the total range of the system as a mark of their own country
Associate ", because this part equivalent to IEC standard, so this sentence is already superfluous, omitted;
--- Fuse system B in Figure B-type table 202 in two dimensions size code "w1" and "w2" in the same column suspected error, respectively
A code to a column;
--- Fuse Systems C and D because the only relevant fuse base, does not involve power dissipation, it will be 8.3 title name "rise and consumption
Scattered power verification "to" accept the power dissipation and temperature verification "; table 302 in terms of the name be amended accordingly;
--- Fuse system F in Figure 2 table 603 of size 8 × 32 and 10 × 38 In value, respectively 16A and 25A suspected
Error, were changed to 25A and 32A;
--- Fuse system J in FIG. "5A" suspected misuse within 1007, to "6A".
This part is proposed by the China Electrical Equipment Industrial Association.
This part of the National Standardization Technical Committee fuse (SAC/TC340) centralized.
This section is responsible for drafting unit. Shanghai Electric Apparatus Research Institute, Shanghai Electric Technology Co., Ltd. Electric Division.
This section participated in the drafting unit. electrical switches Manufacturing Co., Ltd. Ningbo, Zhejiang and Jiangxi melting Electric Co., Ltd. People Electric Group Co., Ltd.
Secretary, Zhejiang Chint Electric Co., Ltd., Suzhou City Southern Light Electric Co., Ltd., the United States and Mickelson Electrical Protection Systems (Shanghai) Co., Ltd., Shanghai
Siemens Circuit Protection Systems Ltd., hollyland (China) Electronic Technology Co., Ltd., Littelfuse Ltd., Wenzhou is three
Electrical Appliance Co., Ltd. Fuse Cooper Xi'an, Shanghai electrical equipment detection.
The main drafters of this section. Wu Qingyun, Ji Yu Hui.
The drafters of some of the participants. the Yin Chang Liang Venus, Le Quoc An, Li Chuan, Li Jianguo, Jia Wei, Zhou Gang, Lai Wenhui, Zhangjun Yan, Huang Xuxiong,
Zhang Yi, Zhang Yi, Liang Lijuan, Zhang Lili.
This part of the standard replaces the previous editions are.
--- GB 13539.2-1992;
--- GB/T 13539.2-2002, GB/T 13539.6-2002;
--- GB/T 13539.2-2008.
Low-voltage fuses
Part 2. fuses for use by full-time staff
Supplementary requirements (mainly for industrial fuses)
Examples of standardized systems of fuses A to K
1 Total range
Fuse professionals use generally designed to be used in order to close the only full-time staff as well as the replacement fuse device.
Unless otherwise specified in GB/T 13539 in this section, the fuse professionals meet the following system requirements to use fuses should break
Co IEC 60269-1 clause requirements.
This section consists of the following systems of fuses, each fuse system involves a specific example of a standard full-time staff to use.
--- Fuse system A. knife type contact fuse (NH fuse system);
Knife type contact fuse with the impactor (NH fuse system);. --- Fuse Systems B
--- Fuse system C. bar fuse bases (NH fuse system);
--- Fuse system D. Fuse base busbar installation (NH fuse system);
--- Fuse system E. bolted fuse (BS bolted fuse system);
--- Fuse system F. cylindrical cap fuse (NF cylindrical cap fuse system);
--- Fuse system G. Offset touch knife fuse (BS fuse clamping system);
--- Fuse Systems H. "gD" and "gN" characteristic Fuse (J type, T type and class L time delay and non-delay fuse type);
--- Fuse system I. gU wedge contact fuse;
--- Fuse Systems J. "CC class gD" and "CC class gN" characteristic Fuse (CC class delay and non-delay fuse type);
--- Fuse Systems K. Knife gK contact bolted fuse (from 1250A to 4800A main fuse high current rating
Off the body).
Note. The above system is the standardized fuse system about its safety.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
IEC 60112 solid insulating materials resistance to tracking index and comparative tracking index method of measurement (Methodforthedetermi-
nationoftheproofandthecomparativetrackingindicesofsolidinsulatingmaterials)
IEC 60269-1 Low-voltage fuses - Part 1. General requirements (Low-voltagefuses-Part 1. Generalrequire-
ments)
IEC 60664-1 within low-voltage systems with insulated equipment - Part 1. Principles, requirements and tests (Insulationcoordination
forequipmentwithinlow-voltagesystems-Part 1. Principles, requirementsandtests)
IEC 60999 (all parts), Connecting devices - Electrical copper conductors are threaded and safety requirements screwless type clamping units (al
parts) (Connectingdevices-Electricalcopperconductors-Safetyrequirementsforscrew-typeand
screwless-typeclampingunits)
IEC 60999-1 Connecting devices - Electrical copper conductors with safety requirements for screw-type and screwless-type clamping units - Part 1. From
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 13539.2-2015_English be delivered?Answer: Upon your order, we will start to translate GB/T 13539.2-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 6 ~ 10 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 13539.2-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 13539.2-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 13539.2-2015?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 13539.2-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|