HOME   Cart(12)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 12810-2021 English PDF

US$339.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 12810-2021: Laboratory glassware - Capacity methods testing and use of volumetric instruments
Status: Valid

GB/T 12810: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 12810-2021English339 Add to Cart 4 days [Need to translate] Laboratory glassware - Capacity methods testing and use of volumetric instruments Valid GB/T 12810-2021
GB/T 12810-1991English559 Add to Cart 3 days [Need to translate] Laboratory glassware. Volumetric galssware. Methods for use and testing of capacity Obsolete GB/T 12810-1991

PDF similar to GB/T 12810-2021


Standard similar to GB/T 12810-2021

GB/T 12807   GB/Z 12414   GB/T 15726   GB/T 12803   

Basic data

Standard ID GB/T 12810-2021 (GB/T12810-2021)
Description (Translated English) Laboratory glassware - Capacity methods testing and use of volumetric instruments
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard N64
Word Count Estimation 17,178
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 12810-2021: Laboratory glassware - Capacity methods testing and use of volumetric instruments


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Laboratory glassware - Capacity methods testing and use of volumetric instruments ICS 81.040.01 CCSN64 National Standards of People's Republic of China Replace GB/T 12810-1991 Laboratory glassware Volume calibration and usage method of glass measure (ISO 4787.2010, Laboratoryglassware-Volumetricinstruments- Released on 2021-08-20 2022-03-01 implementation State Administration of Market Supervision and Administration Issued by the National Standardization Management Committee

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents" Drafting. This document replaces GB/T 12810-1991 "Laboratory glass instrument glass volume calibration and use method", and Compared with GB/T 12810-1991, in addition to structural adjustments and editorial changes, the main technical changes are as follows. --- Changed the scope of application (see Chapter 1, Chapter 1 of the.1991 edition); --- Change the chapter "Capacity Units, Standard Temperature" to "Terms and Definitions" (see Chapter 3, Chapter 4 of the.1991 Edition); --- Deleted the definition of the term "capacity unit" (see 4.1 in the.1991 edition); --- Changed the definition of the term "standard temperature" (see 3.9, 4.2 in the.1991 edition); ---Added the definitions of 8 terms such as measuring-in container and measuring-out measuring device (see 3.1~3.8); ---Change "Method Summary" to "Volume Calibration", and change the expression (see Chapter 3 of 7.1,.1991 Edition); ---Added calibration medium requirements (see Chapter 5); --- Deleted the barometer (see 5.3 in the.1991 edition); --- Deleted the chapter "Factors affecting the accuracy of laboratory measuring instruments" (see Chapter 6 of the.1991 edition); --- Added a chapter "Environmental Requirements for Calibration Laboratories" (see Chapter 6, Table B1 of the.1991 Edition); ---Added the adjustment of the meniscus of the transparent glass containing the transparent liquid (see 7.3.1); ---Added the adjustment of the meniscus of the blue line milky white backing measuring device containing transparent liquid (see 7.3.2); ---Added the adjustment of the meniscus of opaque liquids (see 7.3.3); ---Changed the expression of "glass measure outflow time" (see 7.4, Chapter 8 of the.1991 edition); ---Added the electronic balance weighing method (see 8.3.2.1); ---Changed the volume expansion coefficient of the glass gauge (see 9.1, B1.4 in the.1991 edition); ---Added the calculation method of K(t) value (see 9.3); ---Changed the calculation and presentation of results (see Chapter 9, Appendix B, 9.6, Appendix B of the.1991 edition); ---Added the calibration report (see Chapter 10); --- Deleted the method of cleaning glass measuring vessels with a mixture of saturated potassium dichromate solution and concentrated sulfuric acid (see.1991 edition A2a.); --- Deleted the experimental error related to meniscus calibration (see B1.3 in the.1991 edition); ---Change the table in Appendix B (see B.1, B.2, B.3, B.4, B.5, B.6, Table B3, Table B4, Table B6, Table B7 in the.1991 edition, Table B8, Table B9); --- The additional correction values for the air temperature and pressure of the 1000mL measuring instrument have been deleted (see Table B10 in the.1991 edition). This document is drafted with reference to ISO 4787.2010 "Methods for Calibration and Use of Glass Measuring Instruments for Laboratory Glass Instruments". Degrees are not equivalent. Please note that some of the contents of this document may involve patents. The issuing agency of this document is not responsible for identifying patents. This document was proposed by the China National Light Industry Council. This document is under the jurisdiction of the National Glass Instrument Standardization Technical Committee (SAC/TC178). This document was drafted by. Chinese Academy of Metrology, Beijing Institute of Pharmaceutical Packaging Materials, and Shandong Institute of Metrology. The main drafters of this document. Zhang Long, Wang Jintao, Yuan Chunmei, Tong Lin, Ji Jianying. The previous versions of this document and the documents replaced are as follows. ---This document was first published in.1991, and this is the first revision. Laboratory glassware Volume calibration and usage method of glass measure

1 Scope

This document specifies the volume calibration and usage methods of glass measuring devices. This document is applicable to the calibration and use of glass measuring devices with a capacity range of 0.01mL~5000mL.

2 Normative references

The contents of the following documents constitute the indispensable clauses of this document through normative references in the text. Among them, dated quotations Only the version corresponding to that date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to This document. GB/T 6682 Analytical laboratory water specifications and test methods JJF1009 Capacity measurement terms and definitions

3 Terms and definitions

The following terms and definitions defined in JJF1009 apply to this document. 3.1 Measuringcontainer(tocontain) A measuring device used to measure the volume of liquid in the injection measuring device (the inner wall is dry). [Source. JJF1009-2006, 2.5] Note. The input symbol is represented by "In". 3.2 Measuringcontainer(todeliver) A measuring device used to measure the volume of liquid discharged from the inside of the measuring device. [Source. JJF1009-2006, 2.6] Note. The symbol of the measure-out formula is represented by "Ex". 3.3 Calibration liquid The liquid used in the calibration of the gauge. [Source. JJF1009-2006, 2.5] 3.4 Remaining liquid The amount of liquid remaining on the surface of the inner wall of the measuring device after the liquid inside the measuring device is discharged within the specified time. [Source. JJF1009-2006, 2.11] 3.5 Dischargingtime In order to ensure the measuring accuracy of the measuring device, the prescribed time for all liquid in the measuring device to flow out. [Source. JJF1009-2006, 2.12]

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 12810-2021_English be delivered?

Answer: Upon your order, we will start to translate GB/T 12810-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 12810-2021_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 12810-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 12810-2021?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 12810-2021 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.