US$94.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 10050-2009: Optics and optical instruments -- Reference wavelengths Status: Valid GB/T 10050: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 10050-2009 | English | 94 |
Add to Cart
|
3 days [Need to translate]
|
Optics and optical instruments -- Reference wavelengths
| Valid |
GB/T 10050-2009
|
| GB/T 10050-1988 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Optics and optical instruments--Reference wavelengths
| Obsolete |
GB/T 10050-1988
|
PDF similar to GB/T 10050-2009
Basic data | Standard ID | GB/T 10050-2009 (GB/T10050-2009) | | Description (Translated English) | Optics and optical instruments -- Reference wavelengths | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | N30 | | Classification of International Standard | 37.020 | | Word Count Estimation | 5,510 | | Date of Issue | 2009-09-30 | | Date of Implementation | 2009-12-01 | | Older Standard (superseded by this standard) | GB/T 10050-1988 | | Adopted Standard | ISO 7944-1998, IDT | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 10 of 2009 (No. 150 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard defines two used to represent optical materials, optical systems and optical instruments and reference wavelength of spectacle lenses, and provides the main index, the main dispersion and two types of reference and the main dispersion wavelength Abbe number. |
GB/T 10050-2009: Optics and optical instruments -- Reference wavelengths---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Optics and optical instruments. Reference wavelengths
ICS 37.020
N30
National Standards of People's Republic of China
GB/T 10050-2009/ISO 7944.1998
Replacing GB/T 10050-1988
Optics and optical instruments - Reference wavelengths
(ISO 7944.1998, IDT)
Posted 2009-09-30
2009-12-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard is equivalent to using ISO 7944.1998 "Optics and optical instruments - Reference wavelengths."
This standard is equivalent translation ISO 7944.1998.
For ease of use, this standard also made the following editorial changes.
--- "This International Standard" be replaced by "this standard";
--- Delete international standards foreword.
This standard replaces GB/T 10050-1988 "Optics and optical instruments - Reference wavelengths."
This standard and GB/T 10050-1988 main differences are as follows.
--- Chapter 1, "scope" in the spectacle lens increases the reference wavelength;
--- Increased 2.1 General content;
--- The GB/T 10050-1988 3.1 incorporated in Chapter 2. Table 2;
--- Table 3, an increase of helium-neon laser He-Ne wavelength;
--- Deletion of the GB/T 10050-19883.2 of neodymium (Nd) 1060.0nm, the GB/T 10050-19883.2 helium - neon
(He-Ne) 632.8nm incorporated in Table 3 Chapter 2.
The standard proposed by China Machinery Industry Federation.
This standard by the National Standardization Technical Committee photon science and optics (SAC/TC103) centralized.
This standard is drafted by. Shanghai Polytechnic University.
Participated in the drafting of this standard. Nanjing Jiangnan Yong new Optical Co., Ltd., Ningbo Yongxin Optics Co., Ltd., Suzhou has an optical instrument
Limited.
The main drafters of this standard. Pingqiong Hui, Zhang Hui Yin.
This standard replaces the standards previously issued as follows.
--- GB/T 10050-1988.
GB/T 10050-2009/ISO 7944.1998
Optics and optical instruments - Reference wavelengths
1 Scope
This standard specifies two for representing optical materials, optics and optical instruments as well as the spectacle lens reference wavelength, and provides primary
Refractive index and Abbe number of the main dispersion as well as two reference wavelengths and the main dispersion.
2 reference wavelength, the primary dispersion and Abbe number
2.1 General
Reference wavelength e-line 546.07nm mercury and helium d line 587.56nm. For non-use reference wavelength should ophthalmic mercury e-line. can
Used as a reference wavelength other wavelengths are shown in Table 1, Table 2 and Table 3.
Note. In the future even for ophthalmic use only requires a reference wavelength.
Like e principal refractive index is the refractive index of the green mercury e line, the main dispersion is shaped like F'- C ', wherein. the shape F' blue cadmium F 'line refractive index, like C' red
Color cadmium C 'line of refractive index.
The Abbe number and the main reference wavelength dispersion vp e according to equation (1).
Vp e = e-1-like shape F'- like C '
(1)
D is a refractive index of principal refractive index like yellow helium d line, like the main dispersion F- C shape, wherein. F is the refractive index of the blue like hydrogen F line, C-shaped red
The refractive index of hydrogen C line.
The main reference wavelength dispersion and Abbe number vp d according to equation (2).
Vp d = d-1-like shape C-shaped F-
(2)
Table 1 and recommended reference wavelength in the visible wavelength range of the ultraviolet spectrum
The line used
UV mercury
Purple mercury
Blue Mercury
Blue cadmium
F '
Blue Hydrogen
Green Mercury
Yellow helium
Cadmium red
C '
Red hydrogen
Red helium
Elemental Hg Hg Hg Cd H Hg He Cd H He
Wavelength/nm 365.01a 404.66 435.83 479.99 486.13 546.07 587.56 643.85 656.27 706.52
Reference wavelength /
nm
- - - - - 546.07 587.56 - - -
Principal refractive index - - - - - shaped like e d - - -
Hg using a singlet-triplet.
Table 2 Recommended infrared spectral band wavelengths
Element rubidium Rb Cs cesium Hg Mercury Hg Mercury Hg Mercury Hg Mercury Hg Mercury Hg Mercury Hg mercury
Wavelength/nm 780.0 852.11a 1013.98b 1128.66 1395.1 1529.6 1813.1 1970.1 2325.4
a cesium s;
b Mercury g.
GB/T 10050-2009/ISO 7944.1998
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 10050-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 10050-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 10050-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 10050-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 10050-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 10050-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|