US$2269.00 · In stock Delivery: <= 12 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 6932-2015: Domestic gas instantaneous water heater Status: Valid GB 6932: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB 6932-2015 | English | 2269 |
Add to Cart
|
12 days [Need to translate]
|
Domestic gas instantaneous water heater
| Valid |
GB 6932-2015
|
GB 6932-2001 | English | RFQ |
ASK
|
7 days [Need to translate]
|
Domestic gas instantaneous water heater
| Obsolete |
GB 6932-2001
|
GB 6932-1994 | English | RFQ |
ASK
|
9 days [Need to translate]
|
Domestic gas instantaneous water heater
| Obsolete |
GB 6932-1994
|
GB 6932-1986 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Domestic gas instantaneous water heater
| Obsolete |
GB 6932-1986
|
PDF Samples
Basic data Standard ID | GB 6932-2015 (GB6932-2015) | Description (Translated English) | Domestic gas instantaneous water heater | Sector / Industry | National Standard | Classification of Chinese Standard | Y69 | Classification of International Standard | 97.120 | Word Count Estimation | 108,166 | Date of Issue | 2015-09-18 | Date of Implementation | 2017-01-01 | Older Standard (superseded by this standard) | GB 6932-2001 | Quoted Standard | GB/T 191; GB/T 2828.1; GB/T 2828.2; GB/T 3280; GB 4208; GB 4706.1-2005; GB/T 5013.1; GB/T 5023.1; GB/T 5465.2; GB/T 7306.1; GB/T 7306.2; GB/T 7307; GB/T 12113-2003; GB/T 12206-2006; GB/T 13611; GB 14536.1; GB 14536.6; GB/T 16411-2008; GB/T 17624.1; GB/T 17626.4; GB/T 17626.5; GB/T 17626.11; GB/T 17627.1; GB/T 17799.1-1999; GB 19212.10; CJJ 12 | Regulation (derived from) | National Standard Announcement 2015 No.28 | Issuing agency(ies) | Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China | Summary | This standard specifies the terms and definitions of domestic gas instantaneous water heater, classification and type, material and structural requirements, performance requirements, test methods, inspection rules and signs, installation, packaging, transportation and storage. This standard applies to the rated thermal load of not more than 70 kW of home heating water gas instantaneous water heater (hereinafter referred to as hot water heaters); rated thermal load of not more than 70 kW, maximum working pressure heating is not greater than 0.3 MPa, the heating temperature of not more than indoor forced to exhaust, home heating outdoor gas water heater (hereinafter referred to as heating water heater) and household dual-use gas water heater 95 �� (hereinafter referred to as the rejection of two water heaters), including condensing heating water heaters, heating particular requirements for dual-use water heaters and water heaters. This standard does not apply for a gas storage water heater. |
GB 6932-2015: Domestic gas instantaneous water heater---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Domestic gas instantaneous water heater
ICS 97.120
Y69
National Standards of People's Republic of China
Replacing GB 6932-2001
Domestic gas instantaneous water heaters
Published 2015-09-18
2017-01-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China issued
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative References 1
2 3 Definitions
Category 4 and 5 models
5 Materials and structural requirements 12
6 performance requirements 18
7 22 Test Method
56 8 Inspection Rules
9 flag, installation, packaging, transportation, storage 58
Particular requirements Annex A (normative) heating domestic gas water heater, a home dual type gas water heater 62
Particular requirements Annex B (normative) condensing water heater 72
Annex C (normative) using an alternating current electrical safety heater 79
Annex D (normative) safety and electromagnetic compatibility of electronic control system 88 controls the requirements
Annex E (normative) food content of nitrogen oxides in the combustion flue gas φ [NOx (α = 1)] Grading Rules 93
Annex F (normative) mounting technique requires heater 95
Effects of intrinsic thermal heat loss (normative) indirect method and test device Appendix G of the circulation pump 99
The method of Annex H (normative) determining the ignition time at full load of 100
Foreword
This standard Chapter 5 5.1.6.1,5.1.6.2,5.2.2.2.1,5.2.2.8.1,5.2.2.8.2,5.2.2.9.1,5.2.3.1.1,5.2.3.2.1 ,
Item 5.2.3.3.1,5.2.3.4.1, Chapter 6 boldface in Table 6, Chapter 8 of 8.4.1.1, 9.1.1 in Chapter 9 of b), 9.1.2 of
Item a),) item b, item c), 9.4.1, Appendix A A.2.2.2 of item a) item, b), the term A.2.2.3 b), A.2.3.1, A.2.3.2.3 of a)
Xiang, boldface Table A.1, Appendix B Table B.1 boldface, Appendix C C.2.1, C.2.2, C.7.4 to the bold C.7.1
Portion, boldface bold portion of C.9.1 to C.9.3, C.13.1 to C.13.11 of the bold portion C.14.1 to C.14.5,
Appendix F boldface items F.4.1.1, F.4.1.2, F.4.1.4 and first paragraph a) are mandatory, others are recommended.
This standard was drafted in accordance with rules GB/T 1.1-2009 given.
The standard reference JISS2109.2008 "Gas Water Heater", EN26.1998 "Installation atmospheric household gas burner fast
Fast food "(Amendments comprising 2 and 3).
This standard replaces GB 6932-2001 "Domestic gas instantaneous water heaters."
Compared with this standard GB 6932-2001, except for editorial changes Technical changes are as follows.
--- modified natural structure and the exhaust gas water heater installation requirements (see 5.1.6.1,5.1.6.2,5.2.2.8.1, F.4.1.1);
--- Natural increased water heater exhaust safety device to prevent incomplete combustion (see 5.2.3.3);
--- on the part concerning the structure and use of safe water heaters were perfect (see 5.1.1,5.1.2,5.1.5,5.2.3);
--- increase the gas/air ratio control apparatus according (see 5.2.2.11);
--- standard performance requirements, test methods were perfect (see Chapter 6, Section 7);
--- for domestic heating gas instantaneous water heaters, household gas instantaneous water heater dual-use part of the contents have been revised and improved (see Appendix A);
--- special requirements for increased condensing water heater (see Appendix B);
--- improve the safe use of alternating current electric water heater (see Appendix C);
--- improved electromagnetic compatibility and safety of electronic control systems control requirements (see Appendix D).
This standard, under the jurisdiction of China National Hardware Association, China Association for Standardization.
This standard was drafted. Guangdong Macro Gas Appliance Co., Ltd., Qingdao Economic and Technological Development Zone Haier Water Heater Co., the country burning
Gas appliances Quality Supervision and Inspection Center (Foshan), the national daily Metal Products Quality Supervision and Inspection Center (Shenyang), national gas appliances Quality Supervision
Inspection Center (Tianjin), Zhongshan Vantage Gas Appliance Co., Ltd., the rate of energy (China) Investment Co., Ltd., Guangdong million and the new Electric Company Limited
Secretary, AO Smith (China) Water Heater Co., Ltd., Guangdong Shenzhou Gas Appliances Co., Ltd., Sakura (China) Co., Ltd., to
Are forward Electronics Co., Ltd., the highest Stewart Thermal Technology (Zhongshan) Co., Ltd., Guangdong Midea Electric Manufacturing Co., Ltd. kitchen, Guangdong gold
Mita Industrial Co., Ltd., Guangdong Hesheng Metal Manufacturing Co., Ltd., Shanghai Rinnai Co., Ltd., Ningbo, too kitchenware Ltd., Zhongshan Decker
Kitchen & Bath Co., Ltd., Zhongshan City, Sakura Ice Holdings Limited, Ariston Thermo Products (China) Co., Ltd., Zhejiang German, Italian and kitchen utensils Limited.
The main drafters. Shao Yan, Hu set steel, Zheng Tao, Zhang Mingwei, Jin Feng, Liu Tong, Yi Hongbin, Zhang Kundong, Zhong Song, Qiu step,
Li Jianhao, Huang Jin, Yang Gang, Zhang Jixiang, Liang Guorong, Zhu Baohua, six Tan Ming, Jiang Hua, Xu Deming, Guo Li, Zhou Yulin, quarter soldiers, Pu Xi An.
This standard supersedes the previous editions are.
--- GB 6932-1994, GB 6932-2001.
Domestic gas instantaneous water heaters
1 Scope
This standard specifies a domestic gas water heater terms and definitions, and the classification models, materials and structural requirements, performance requirements, Standard Test
Method, inspection rules and signs, installation, packaging, transportation and storage.
This standard applies to domestic gas water heater hot-water supply load is not greater than the nominal heat of 70kW (hereinafter referred to as hot water heaters);
Nominal heat is not greater than 70kW, working pressure is not greater than the maximum heating 0.3MPa, heating temperature not greater than 95 deg.] C to room Forced
Vent type, home heating outdoor gas instantaneous water heater (hereinafter referred to as heating water heater) and a dual-type household gas instantaneous water heater (hereinafter
Said dual heater), heating comprising condensing water heaters, water heaters, and heating heaters dual specific requirements.
This standard does not apply to gas storage water heater.
Note 1. This standard gas referred to is GB/T 13611 "town gas classification and basic characteristics", a predetermined gas GB 13612 "artificial gas", using the GB/T 13611
When outside a predetermined gas, a gas test was carried out with gas provided by the product design, the relevant pressure range with reference to a predetermined GB/T 13611's.
Note 2. domestic gas water heater hot-water supply, heating domestic gas water heater, dual-type gas water heater household collectively domestic gas heat
Water (hereinafter referred to as heater).
2 Normative references
The following documents for the application of this document is essential. For dated references, only applies to the version dated paper
Pieces. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 191 Packaging Pictorial signs
GB/T 2828.1 Sampling procedures - Part 1. press-batch inspection sampling plan reception quality limit (the AQL) search
GB/T 2828.2 Sampling procedures - Part 2. Test batch sampling plan isolated by limiting quality (LQ) search
GB/T 3280 cold rolled steel and stainless steel
GB 4208 shell protection (IP code)
Part 1 GB 4706.1-2005 Safety of household and similar electrical appliances. General requirements
GB/T 5013.1 rated voltage of 450/750V and Rubber insulated cables - Part 1. General Requirements
GB/T 5023.1 rated voltage of 450/750V and below PVC insulated cables - Part 1. General Requirements
GB/T 5465.2 electrical equipment Graphical symbols Part 2. Graphical symbols
GB/T 7306.1 55 ° pipe thread seal Part 1. the inner cylinder and the taper thread external thread
GB/T 7306.2 55 ° pipe thread seal Part 2. Taper internal and the external threads
GB/T 730755 ° non-sealing pipe thread
GB/T 12113-2003 touch current and protective conductor current measurement
GB/T 12206-2006 town gas heating value and relative density of
GB/T 13611 Classification and essential property of city gas
GB 14536.1 household and similar use automatic controller Part 1. General Requirements
GB 14536.6 household and similar use electrical burner automatic controller automatic control system specific requirements
GB/T 16411-2008 domestic gas appliances General Test Method
GB/T 17624.1 Electromagnetic compatibility General EMC basic terms and definitions apply to the interpretation
GB/T 17626.4 Electromagnetic compatibility testing and measurement techniques Electrical fast transient burst immunity test
GB/T 17626.5 Electromagnetic compatibility testing and measurement techniques surge (impact) immunity test
GB/T 17626.11 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
GB /17627.1 first portion of the high voltage test techniques for low voltage equipment T. Definitions and test requirements
GB/T 17799.1-1999 Electromagnetic compatibility - Generic standards Immunity for residential, commercial and light industrial environments
GB 19212.10 transformers, reactors, power supply devices, and combinations Safety Part 10. Ⅲ portable type for filament transformer
Particular requirements and test power supply unit and
CJJ12 domestic gas burning appliances installation and acceptance
3 Terms and Definitions
GB 4706.1-2005, GB/T 13611, GB 14536.1, GB 14536.6, GB/T 16411-2008, GB/T 17624.1 defined
T......
|