HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (14 Jun 2025)

English GB 30734-2014 PDF

Search result: GB 30734-2014
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB 30734-2014English279 Add to Cart 3 days [Need to translate] Luminaires for firefighters Valid GB 30734-2014


BASIC DATA
Standard ID GB 30734-2014 (GB30734-2014)
Description (Translated English) Luminaires for firefighters
Sector / Industry National Standard
Classification of Chinese Standard C85
Classification of International Standard 13.220.10
Word Count Estimation 12,132
Date of Issue 6/9/2014
Date of Implementation 4/1/2015
Quoted Standard GB/T 191-2008; GB/T 2423.1-2008; GB/T 2423.2-2008; GB/T 2423.4-2008; GB/T 2423.10-2008; GB/T 3836.1-2010; GB 4208-2008; GB 7000.1-2007
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This Standard specifies the definition of firefighters lighting, classification and models, technical requirements, test methods, inspection rules, marking, packaging, transport and storage.


GB 30734-2014 Luminaires for firefighters ICS 13.220.10 C85 National Standards of People's Republic of China Firemen Lighting Issued on. 2014-06-09 2015-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Foreword The first chapter of this standard 8.1 5,7 mandatory, the rest are recommended. This standard is prepared in accordance with GB/T 1.1-2009 given rules. The standard proposed by the People's Republic of China Ministry of Public Security. This standard by the National Standardization Technical Committee firefighters Fire Protection Equipment Technical Committee (SAC/TC113/SC12) centralized. This standard was drafted. Shanghai Fire Research Institute of Ministry of Public Security. The main drafters of this standard. Ma Weiguang, Zhou Kai, Li Rui Kun, Yan Haibo, Wu Yun, Cao Yongqiang, Zhang Yan, Chang Song, Liu Yongmei, Liusu Yan, Xie Chunlong, Xu Jian, Li Miaohua. Firemen Lighting 1 Scope This standard specifies the definition of firefighters lighting, classification and models, technical requirements, test methods, inspection rules, marking, packaging, transport Transport and storage. This standard applies when firefighters were fighting and rescue operations for single use lighting in a variety of low-light settings. 2 Normative references The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 191-2008 Packaging - Pictorial signs GB/T 2423.1-2008 Environmental testing for electric and electronic products Part 2. Test methods Test A. Cold GB/T 2423.2-2008 Environmental testing for electric and electronic products Part 2. Test methods Test B. Dry heat GB/T 2423.4-2008 Environmental testing for electric and electronic products Part 2. Test methods - Test Db. Damp heat (12h 12h cycle) GB/T 2423.10-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Fc. Vibration (sinusoidal) GB 3836.1-2010 explosive atmospheres - Part 1. General requirements for equipment GB 4208-2008 shell protection (IP code) GB 7000.1-2007 Luminaires - Part 1. General requirements and tests 3 Terms and Definitions The following terms and definitions apply to this document. 3.1 Firefighters lighting luminaireforfirefighter Lighting firefighters single use. 3.2 Wearable firefighters lighting wearableluminaireforfirefighter Fixed firefighters wear when used in a certain part of the body of firemen lighting. 3.3 Portable type Ⅰ firefighters lighting typeⅠhandheldluminaireforfirefighter Mass of less than or equal to 1.5kg, when using hand-held or portable lighting light firefighters. 3.4 Portable Ⅱ-based firefighters and lighting typeⅡhandheldluminaireforfirefighter Mass greater than 1.5kg but less than or equal to 25kg, when using a portable or drag heavy firefighters lighting. 3.5 Lamp lightingassembly Lighting fixture part, by the light emitting devices, reflectors, consisting of transparent components. 4 Classification and models 4.1 Classification Fireman lighting (hereinafter referred to as lamp) in accordance with the use classification, category and code are shown in Table 1. Table 1 Category Code Category Name Wearable P Portable Ⅰ type SⅠ Type Ⅱ SⅡ 4.2 Model Preparation of models of lighting products should meet the following requirements. Fireman protective equipment D- Lighting FB Explosion code Category Code Continuous light stability time in minutes (min) / □ Enterprise custom code (consisting of the letters or Arabic numerals) Example. FD-FBSⅠ240/A represents light continuous working time 240min stable Ⅰ portable explosion-proof lighting class firefighters, business custom Codenamed A. 5 Technical requirements 5.1 General Requirements 5.1.1 lighting power supply should be used rechargeable batteries, battery replaceable lamps should be equipped with an independent battery charging cradle. 5.1.2 Lamps charger plug should be used with AC-DC converter separate structure, fixture or charger should be set to charge and discharge protection circuit. 5.1.3 explosion-proof lamps shall comply with the requirements of GB 3836.1-2010. 5.1.4 wearable lamps should have a fire helmet match fixing fittings. 5.2 Functional requirements 5.2.1 The lamps should have a strong, low-light switching function. 5.2.2 The lamps should have flashes of low-voltage alarm function. 5.3 Performance Requirements 5.3.1 Appearance and assembly 5.3.1.1 Exterior lighting should be clean, smooth, clean, non-fouling, corrosion, scratches, burrs, cracks, deformation phenomena. 5.3.1.2 Each component mounting fixtures should be complete, accurate, reliable, no defects, dislocation, loosening, switching operation should be convenient, flexible and reliable. 5.3.2 Quality Quality lamps (including battery and accessories) shall comply with the provisions of Table 2. Table 2 units of kilograms Quality category Wearable ≤0.15 Portable Ⅰ type ≤1.5 Ⅱ type> 1.5 and ≤25.0 5.3.3 Illumination When you press the test method specified in 6.5, lighting illuminance values under steady state should be in accordance with Table 3. table 3 category Measuring distance Test beam diameter mm Illuminance lx Light low light Average Minimum Average Minimum Wearable 2 150 ≥450 ≥300 ≥200 ≥150 Portable Ⅰ type 5 300 ≥250 ≥150 ≥150 ≥100 Ⅱ type 10 800 ≥500 ≥300 ≥200 ≥100 5.3.4 continuous and stable working time Lamps continuous and stable working hours shall comply with the requirements of Table 4. Table 4 in min. category Continuous and stable continuous working time working time under low voltage state Low light bright light low light Wearable ≥240 ≥480 Portable Ⅰ type ≥300 ≥600 Type Ⅱ ≥560 ≥840 ≥15 ≥30 5.3.5 low voltage alarm time Lamps low voltage alarm time should be 10s ~ 20s. 5.3.6 continuous working time at a low voltage condition Lamps at a low voltage state of continuous working hours shall comply with the requirements of Table 4. 5.3.7 insulation At room temperature environment, the insulation resistance between the shell and the lighting live terminal shall not be less than 20MΩ, after alternating hot and humid test shall not be less than 5MΩ. 5.3.8 withstand voltage performance Lamps should be able to withstand a frequency of 50Hz ± 0.5Hz, AC voltage 500V ± 50V, which lasted withstand voltage test of the 60s ± 5s. test Inspection procedure, the lamp should surface arcing and breakdown phenomenon. After the test, the lamp shall be able to be opened and closed strong, low light switch. 5.3.9 weatherability environmental performance Lamps should be able to withstand the test specified in Table 5 climate conditions. After each test, the lamp shall be able to be on, off and Strong, low-light switch. table 5 Test Project Name Test Parameters Test Conditions Sample status Low temperature performance High temperature performance temperature -25 ± 2 duration temperature 55 ± 2 duration Light work status Alternating hot and humid performance Cold storage High-temperature storage temperature 25 ± 3 Rose 40 ± 2 40 ± 2 40 ± 2 Drops 25 ± 3 25 ± 3 Relative humidity 95 ~ 10 090 ~ 10 095 ~ 9680 100 ~ duration temperature -40 ± 2 duration Recovery time at room temperature temperature 70 ± 2 duration Recovery time at room temperature Nonoperating 5.3.10 Resistance to mechanical environmental performance Live table lamps should be able to withstand the tests specified under 6 Mechanical ambient conditions. After each test, the lamp should be no mechanical damage and fastening Piece loose and can normally open, close and strong, low light switch. Table 6 Test Project Name Test Parameters Test Conditions Sample status Anti-vibration (sinusoidal) performance Anti-drop performance Loop frequency range Hz 10 to 150 Acceleration amplitude Sweep rate oct/min The vibration direction X, Y, Z Each axis scanning cycles 10 Drop height Wearable 1.5 Portable type Ⅰ 1.0 Portable Ⅱ Type 0.5 Drop directions X, Y, Z Number of drops 1 per axis Nonoperating 5.3.11 Switch reliability Lamps after 50,000 switching reliability test should be kept intact, and the lamps shall be able to light up and to achieve strong, low-light switch. 5.3.12 enclosure class Luminaire enclosure rating requirements should be GB/T 4208-2008 the provisions of IP66/IP67 or IP66/IP68 of. When protection Class IP66/IP68, the manufacturer shall identify the diving depth and duration of the lamp. 6 Test methods 6.1 Test Environment If no special instructions related provisions, the test should be carried out under the following atmospheric conditions. a) Temperature. 15 ℃ ~ 35 ℃; b) Relative humidity. 45% ~ 75%; c) Atmospheric pressure. 86kPa ~ 106kPa. 6.2 Function Test 6.2.1 Operation lamp switch, check the strong lamps, low-light switching function. 6.2.2 The lighting at a low voltage state, flashes through sensory inspection lamps and low voltage alarm form. 6.3 Appearance and assembly inspection Observation through the senses, touch, appearance and assembly inspection operation. 6.4 Quality Measurement With an accuracy of not less than 1g of electronic scales measuring quality lamps. 6.5 illuminance measurement After the lamp is fully charged, in the dark (no light is completely sealed space) in the open light switch, after sustained 10min, respectively, in the lamp intensity Light, low light condition, as shown in Figure 1, in front of the press table lamp test specified distance of 3, along the direction of the beam diameter, with a distributed light meter The average illuminance distribution point on the measured value of 5 predetermined beam diameter. The arithmetic mean and minimum measurements taken 5.00 as the illuminance value. 6.6 continuous and stable work time test After discharge lamps, then full power, turn on the switch, respectively, in the lamp light, low light and with the state of the timer is started, press When the method of continuously measured and recorded 6.5 illuminance values fixture until it is less than the minimum specified in Table 3 illumination or appear low voltage warning status Stop timer. The time is the time to work for a stable fixture. 6.7 Low voltage alarm time trial After discharge lamps, then full power, turn on the switch, respectively, in the lamp light, low light condition, when the lamp in the light, low light status Under low voltage alarm occurs when, with a timer is started until the lamp flashes a low voltage alarm status and stop it when disappears. This time Room lighting is low voltage alarm time. Continuous working time test at 6.8 low voltage state In 20 consecutive times charge and discharge after the lamp is fully charged, turn on the switch, respectively, in the lamp light, low light condition, when the light fixture, Low voltage alarm state low light condition disappears with the timer is started, according to the method of continuously measured and recorded 6.5 lamp illumination Value until the timer is stopped when the illumination is less than the minimum specified in Table 3 it. The next time the lamp is a low voltage state of continuous work time. Explanation. 1 --- backplane; 2 --- distributed according to meter; 3 --- wire 4 --- lamps; 5 --- lamp bracket; 6 --- bracket rails; 7 --- illuminance measurement analysis system. Figure 1 illuminance measurement method 6.9 insulation test Conducted in accordance with GB 7000.1-2007 10.2.1. Voltage resistance test 6.10 Conducted in accordance with GB 7000.1-2007 in 10.2.2. 6.11 low temperature performance test Low-temperature test according to the test conditions and GB/T 2423.1-2008 provisions of Table 5 below. 6.12 High Temperature Performance Test Tested in accordance with test conditions of high temperature and GB/T 2423.2-2008 provisions of Table 5 below. 6.13 Damp heat test performance It is tested according to Table 5 alternating hot and humid conditions and test GB/T 2423.4-2008 then performed according to the method prescribed in 6.9 Insulation test. 6.14 low temperature storage test Table 5 low temperature storage specified test conditions and GB/T 2423.1-2008 were tested. 6.15 high temperature storage test Table 5 in the high-temperature storage test conditions and GB/T 2423.2-2008 requirements for testing. 6.16 vibration resistance test Tested by vibration (sinusoidal) test conditions and GB/T 2423.10-2008 provisions in Table 6. 6.17 anti-drop performance test Table 6 in accordance with the provisions of the height of the test, the lamp along the X, Y, Z three-axis directions of the drops to a concrete floor. 6.18 Switch reliability test In the off power conditions, the lamp switch 50 000 consecutive operations. 6.19 Enclosure protection class test Shell protection test fixture according to GB 4208-2008 Chapter 13, the provisions of Chapter 14 of the test method. 7 Inspection rules 7.1 Inspection classification The test fixture into the factory inspection and type testing. 7.2 factory inspection 7.2.1 factory inspection to every 100 pieces (sets) of a group, less than 100 (sets) the actual production capacity, each batch of randomly selected two (sets) Submit test. 7.2.2 factory inspection items should include at least 5.3.1,5.3.2,5.3.3,5.3.5,5.3.7,5.3.8,5.3.12. If a failure, then to Nonconforming items doubled sampling, if still fail to meet, the batch of lighting products factory inspection to be ineligible. 7.3 Type inspection 7.3.1 When one of the following conditions, type of inspection should be carried out. a) new product trial stereotypes and old products to the plant; b) There are major changes that may affect product performance and styling product materials, design, construction, technological aspects; c) Product Discontinuance year to resume production; d) the occurrence of major quality accidents. 7.3.2 type test sample should be factory inspection of products at random, the number of samples of three (sets). 7.3.3 type test items and test procedures shall be in accordance with Table 7. 7.3.4 type test results of the project complies with this standard, the contractor type inspection qualified. Table 7 Terms of Reference Standard No. Name of Project Sample number 1 5.1 General requirements √ √ √ 2 5.2 Functional requirements √ √ √ 3 5.3.1 Appearance and assembly quality √ √ √ 4 5.3.2 Quality √ √ √ 5 5.3.3 illuminance √ √ √ 6 5.3.4 Continuous and stable operating hours Light √ Low Light √ 7 5.3.5 low voltage Alarm time Light √ Low Light √ 8 5.3.6 Low voltage state Continuous working time Light √ Low Light √ 9 5.3.7 insulation √ 10 5.3.8 withstand voltage characteristic √ 5.3.9 Weather Environmental performance Low temperature performance √ High temperature performance √ Alternating hot and humid performance √ Cold storage √ High-temperature storage √ 5.3.10 Resistance to mechanical Environmental performance Anti-vibration (sinusoidal) Performance √ Anti-drop performance √ 18 5.3.11 Switch reliability √ 19 5.3.12 enclosure class √ 20 8.1.1 Lamps sign √ √ √ 21 8.1.2 Charger mark √ √ √ Note. "√" indicates that the item be tested. 8 signs, packaging, transportation and storage 8.1 mark 8.1.1 Lamps Flag Position should have clear and obvious lighting and lighting as one of the signs, including the following. a) the product name; b) Model; c) protection class (class IP66/IP68, the need to label diving depth and duration); d) proof mark; e) date of manufacture; f) Product Code; g) production plant name. 8.1.2 Charger logo Location charger should be clearly evident, durable signs, including the following. a) the product name; b) Model; c) adaptation fixture type; d) the date of manufacture; e) the number; f) the name of the production plant. 8.1.3 Package mark It shall be printed on the box obvious, clear, durable text signs, including the following. a) Product name, model; b) the number of products; c) the date of manufacture; d) production plant name and address; e) Dimensions and weight; f) the implementation of standards; g) upwards, moisture, and other signs with care, and should be consistent with GB/T 191-2008 provisions relating to the mark. 8.2 Packaging Packaging lamps and accessories for plastic bags, cartons or plastic bubble wrap and then, along with product certification and instructions for use. 8.3 Transport Products during transport, to avoid stress, collisions, rain. 8.4 Storage Lamps should be stored in a place ventilated, dry, clean and non-corrosive chemicals. ......

Similar standards: GB 23864   GB 32157   GA 10   GB 30077   GB 32459   GB 21976.2