GB/T 14049-2008 English PDF

US$459.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 14049-2008: Aerial insulated cables for rated voltage of 10kV
Status: Valid

GB/T 14049: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 14049-2008English459 Add to Cart 4 days [Need to translate] Aerial insulated cables for rated voltage of 10kV Valid GB/T 14049-2008
GB 14049-1993English679 Add to Cart 5 days [Need to translate] Aerial insulated cables with rated voltages of 10kV and 35kV Obsolete GB 14049-1993

PDF similar to GB/T 14049-2008


Standard similar to GB/T 14049-2008

GB/T 12706.3   GB/T 12706.1   GB/T 12706.4   GB/T 29631   GB/T 11017.2   GB/T 11017.1   

Basic data

Standard ID GB/T 14049-2008 (GB/T14049-2008)
Description (Translated English) Aerial insulated cables for rated voltage of 10kV
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K13
Classification of International Standard 29.060.20
Word Count Estimation 20,217
Date of Issue 2008-06-30
Date of Implementation 2009-04-01
Older Standard (superseded by this standard) GB 14049-1993
Quoted Standard GB/T 1179-1999; GB/T 2951.1-1997; GB/T 2951.2-1997; GB/T 2951.5-1997; GB/T 3048.4-2007; GB/T 3048.5-2007; GB/T 3048.7-2007; GB/T 3048.8-2007; GB/T 3048.11-2007; GB/T 3048.12-2007; GB/T 3682-2000; GB/T 3953-1983; GB/T 3955-1983; GB/T 4909.2-1985; GB/T 4909.3-1985; GB/T 6995.3-2008; JB/T 8134-1995; JB/T 8137-1999; JB/T 10696.3-2007
Regulation (derived from) Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the amount of voltage 10kV AC overhead insulated cable product models, specifications, technical requirements, test methods, inspection rules, packaging, transportation and storage. This standard applies to the amount voltage AC U (Um) to 10 (12) kV overhead power lines with copper, aluminum, aluminum alloy core cross-linked polyethylene and high density polyethylene insulated aerial cables.

GB/T 14049-2008: Aerial insulated cables for rated voltage of 10kV

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Aerial insulated cables for rated voltage of 10kV ICS 29.060.20 K13 National Standards of People's Republic of China Replacing GB 14049-1993 Rated voltage overhead insulated cable 10 k Vp Posted 2008-06-30 2009-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Symbols and code 2 5 using the characteristics of 2 6 Models and Specifications 2 7 3 Technical requirements 8 9 Test Method 9 Acceptance Rule 10 10 packaging, transportation and storage 10 Appendix A (normative) overhead cable insulation material performance requirements of semi-conductive shielding material 11 Appendix B (normative) overhead cable insulation adhesion (slipping) Test Method 13 Annex C (normative) Artificial weathering test method (xenon lamp method) 15

Foreword

This standard replaces GB 14049-1993 "rated voltage of 10kV, 35kV overhead insulated cables." This standard compared with GB 14049-1993, the main changes are as follows. --- Standard name changed to "rated voltage of 10kV overhead insulated cables"; --- Deleted on the rated voltage 35kV overhead insulated cable entry (1993 Edition Chapter 1, 3.1.3,4.1, Table 2, Table 3, 7.7.2, Table 5, Table 8); --- Increasing the nominal cross section 400mm2 (Table 2, Table 3); --- Delete Conductor Stranding pitch diameter ratio and a predetermined twist to the (1993 version 7.2.5); --- A sign of increased core method (see 7.3.4); --- Delete shielded cable insulation partial discharge as a routine test project (1993 version 7.7.4); --- Modify the impulse voltage test value of 10kV overhead line (1993 edition Table 8 Table 8 of this standard); --- According to GB/T 1.1-2000 modified format. The Standard Appendix A, Appendix B and Appendix C are normative appendix. The standard proposed by China Electrical Equipment Industrial Association. This standard by the national wire and cable Standardization Technical Committee (SAC/TC213) centralized. This standard was drafted. Shanghai Electric Cable Research Institute, Jiangsu Far East Group Co., Ltd., Haikou Wit Electric Group Co., Ltd., Fujian Nanping Sun Cable Co., Ltd., Wuxi Jiangnan Cable Co., Ltd., Yangzhou Shuguang Cable Co., Ltd., Hunan Valin Cable Co., Ltd. Drafters of this Standard. Sun Jiansheng, Wang Chuanbin, Mongolia Zhong Kui, Van der hair, Liu Jun, Liang Guohua, Zhang Gongzhuo. This standard replaces the standards previously issued as follows. --- GB 14049-1993. Rated voltage overhead insulated cable 10 k Vp

1 Scope

This standard specifies the rated AC voltage of 10kV overhead insulated cables (overhead cable) product models, specifications, technical requirements, test side Law, inspection rules, packaging, transportation and storage. This standard applies to AC rated voltage U (Um) 10 (12) kV overhead power lines with copper, aluminum, aluminum alloy core crosslinked poly Ethylene (XLPE) and high density polyethylene (HDPE) insulated aerial cables.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 1179-1999 Round wire concentric gallows empty line (eqv IEC 61089.1991) GB/T 2951.1-1997 cable insulation and sheathing materials test methods - Part 1. General Test Methods 1. Thick Degree and dimension measurement - mechanical physical performance test (idt IEC 60811-1-1.1993) GB/T 2951.2-1997 cable insulation and sheathing materials test methods - Part 1. General test methods - Part 2. Hot Aging methods (idt IEC 60811-1-2. 1985) GB/T 2951.5-1997 cable insulation and sheathing materials test methods - Part 2. General test elastomeric compounds Party Act 1. Ozone resistance test - Hot set test - Mineral oil immersion test (idt IEC 60811-2-1. 1986) GB/T 3048.4-2007 electrical wire and cable performance test methods - Part 4. Conductor DC resistance test GB/T 3048.5-2007 electrical wire and cable performance test methods - Part 5. Insulation resistance test GB/T 3048.7-2007 electrical wire and cable performance test methods - Part 7. Tracking resistance test GB/T 3048.8-2007 electrical wire and cable performance test methods - Part 8. AC voltage test (IEC 60060-1. 1989, NEQ) GB/T 3048.11-2007 wire and cable electrical performance test methods - Part 11. dielectric loss tangent test GB/T 3048.12-2007 wire and cable electrical performance test methods - Part 12. Partial discharge tests (IEC 60885-3. 1988, MOD) GB/T 3682-2000 quality thermoplastic melt flow rate and melt volume flow rate measurement (idt ISO 1133. 1997) GB/T 3953-1983 electrician round copper wire (neqASTMB1. 1970) GB/T 3955-1983 electrician round aluminum (neqASTMB230. 1977) GB/T 4909.2-1985 Test methods for bare wires sizing (neqIEC 60251. 1978) GB/T 4909.3-1985 Test methods for bare wires tensile test (neqIEC 60207. 1966) GB/T 6995.3-2008 wire and cable identification - Part 3. Wire and cable identification JB/T 8134-1995 electrician round aluminum and aluminum alloy wire round Mg-Si alloy round wire JB/T 8137-1999 (all parts) wire and cable delivery plate JB/T 10696.3-2007 wire and cable mechanical and physical and chemical test methods - Part 3. Bending tests

3 Terms and definitions

3.1 Rated voltage is the reference voltage cable design and operation, represented by U (Um), in units of kV. U --- cable between two phase conductors

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 14049-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 14049-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 14049-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 14049-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 14049-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 14049-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.