GB 1002-2024 (GB1002-2024) & related versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | See Detail | Status | Similar PDF |
GB 1002-2024 | English | 485 |
Add to Cart
|
0-9 seconds. Auto delivery.
|
Single phase plugs and socket-outlets for household and similar purposes - Types, basic parameters and dimensions
|
GB 1002-2024
| Valid |
GB 1002-2024
|
GB/T 1002-2021 | English | 215 |
Add to Cart
|
0-9 seconds. Auto delivery.
|
Single phase plugs and socket-outlets for household and similar purposes -- Types, basic parameters and dimensions
|
GB/T 1002-2021
| Valid |
GBT 1002-2021
|
GB 1002-2008 | English | 85 |
Add to Cart
|
0-9 seconds. Auto delivery.
|
[GB/T 1002-2008] Single phase plugs and socket-outlets for household and similar purposes. Types, basic parameters and dimensions [Quasi-Official / Academic version - translated by Chinese Institute]
|
GB 1002-2008
| Obsolete |
GB 1002-2008
|
GB 1002-1996 | English | 85 |
Add to Cart
|
0-9 seconds. Auto delivery.
|
Single phase plugs and socket-outlets for household and similar purposes. Types, basic parameters and dimensions
|
GB 1002-1996
| Obsolete |
GB 1002-1996
|
GB 1002-1980 | English | RFQ |
ASK
|
3 days
|
Types, basic parameters and dimensions of single phase plugs and sockets
|
GB 1002-1980
| Obsolete |
GB 1002-1980
|
Preview this PDF: GB 1002-2024
GB 1002-2024
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 29.120.30
CCS K 30
Replacing GB/T 1002-2021
Single Phase Plugs and Socket-outlets for Household and
Similar Purposes - Types, Basic Parameters and Dimensions
ISSUED ON: JULY 24, 2024
IMPLEMENTED ON: AUGUST 1, 2025
Issued by: State Administration for Market Regulation;
Standardization Administration of the People’s Republic of China.
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative References ... 5
3 Terms and Definitions ... 6
4 Technical Requirements ... 6
5 Test Methods ... 10
6 Implementation of Standard ... 12
Bibliography ... 30
Single Phase Plugs and Socket-outlets for Household and
Similar Purposes - Types, Basic Parameters and Dimensions
1 Scope
This document specifies the types, basic parameters and dimensions of single-phase plugs and
socket-outlets for household and similar purposes, and describes the corresponding test
methods.
This document is applicable to single phase plugs and socket-outlets for household and similar
purposes, with an AC frequency of 50 Hz, a rated voltage of 250 V and a rated current not
exceeding 32 A.
NOTE: examples of products, to which, the types and dimensions of this document are applicable
include:
---socket-outlets used in household scenarios;
---plugs provided with electrical equipment;
---plugs of direct plug-in equipment;
---fixed integrated AC-powered socket-outlets with a rated voltage of 220 V and for
conductive charging of electric vehicles;
---charging socket-outlets in centralized charging facilities for electric bicycles and electric
motorcycles.
2 Normative References
The contents of the following documents constitute indispensable clauses of this document
through the normative references in the text. In terms of references with a specified date, only
versions with a specified date are applicable to this document. In terms of references without a
specified date, the latest version (including all the modifications) is applicable to this document.
GB/T 1184-1996 Geometrical Tolerancing - Geometrical Tolerance for Features without
Individual Tolerance Indications
GB/T 2099.1-2021 Plugs and Socket-outlets for Household and Similar Purposes - Part 1:
General Requirements
GB/T 2099.3 Plugs and Socket-outlets for Household and Similar Purposes - Part 2-5: Particular
Requirements for Adaptors
GB/T 2900.70-2008 Electrotechnical Terminology - Electrical Accessories
3 Terms and Definitions
The terms and definitions defined in GB/T 2900.70-2008 and GB/T 2099.1-2021, and the
following are applicable to this document.
3.1 direct plug-in equipment
An equipment, in which, the power plug and the equipment shell constitute an integral part.
NOTE: examples of direct plug-in equipment include shavers with rechargeable batteries, night
lights mounted on electrical socket-outlets, plug-in transformers and power adapters, etc.
[source: GB 4943.1-2022, 3.3.3.1, modified]
4 Technical Requirements
4.1 General Requirements
4.1.1 Single phase plugs and socket-outlets for household and similar purposes are divided into
two basic types: two-pole ungrounded and two-pole grounded.
4.1.2 The types, basic parameters and dimensions of the single-phase plugs and socket-outlets
for household and similar purposes shall comply with the provisions of Figure 1 ~ Figure 6.
4.1.3 In addition to fixed socket-outlets, for mobile (portable) socket-outlets, converters and
appliance socket-outlets, arrangement and combination of the socket jack in Figure 2 and the
socket jack in Figure 4 are allowed, but the socket jack in Figure 2 and the socket jack in Figure
4 shall not overlap or be shared with each other. Figure 7 provides a schematic diagram.
NOTE 1: the arrangement and combination of socket jack here cannot be comprehended as adding
corresponding plug types.
NOTE 2: the schematic diagram in Figure 7 does not exclude other forms of combinations.
NOTE 3: examples of fixed socket-outlets include wall-mounted socket-outlets.
4.1.4 The position of the plug bush of two-pole grounded socket-outlets shall be such that when
facing the socket-outlets, the ground wire (E pole) is at the top, the neutral wire (N pole) is on
the left, and the phase wire (L pole) is on the right. The position of the pin of two-pole grounded
plugs shall correspond to that of the socket-outlets.
4.1.5 The single pin of a plug shall not undergo axial rotation that changes the type and position.
NOTE: axial rotation, for example, by twisting the pin, changes the two parallel-arranged pins of
the plug in Figure 1 to the position of the phase pole and neutral pole arrangement shown
in Figure 3.
4.1.6 The strength of the inner frame of the fixed pin of non-rewireable plug shall be able to
ensure the stability of the pin size, and the type and dimensions shall comply with the
requirements of the corresponding dimensional drawings.
4.2 Plugs
4.2.1 Plug shape
The shape of the plugs is not specified, but the distance between the root of the live pin of the
plugs and the edge of the plugs shall not be less than 6.5 mm.
NOTE 1: if there is an insulating sheath, then, take the metal pin after the insulating sheath is peeled
off as the root.
NOTE 2: if the mating surface of the plug is not a plane, then, from a plane that passes through the
highest point of the mating surface and is perpendicular to the axis of the plug, the line
that is offset 1 mm towards the direction of the plug body and intersects the surface of
the body is regarded as the edge of the plug. An example is the B value in Figure 8.
The protruding part of the plug mating surface shall not exceed 0.5 mm. The length of the plug
pin shall be measured from the vertical plane of the pin at the highest point of the plug mating
surface, till the top of the pin.
NOTE 3: examples of “protrusions” include the electrical parameters and trademarks, etc. formed
by the injection molding of the plug mating surface, or other appearance structures that
may affect the plug mating.
NOTE 4: for plugs with functional parts on the mating surface, when inserted into the socket-outlet,
the gap between the plug mating surface and the socket-outlet surface does not exceed 1
mm.
NOTE 5: the length of the plug pin is considered to be the effective length of the metal pin part
inserted into the socket-outlet.
4.2.2 Insulating sheath of pin
4.2.2.1 The live pin of the plug shall have an insulating sheath.
NOTE: the insulating sheath can adopt processes, such as: insert injection molding and adhesive
backing, etc.
4.2.2.2 For the plug in Figure 1, the height of the insulating sheath shall be 7.00.50 mm; for the plug in Figure 3 and Figure 5, the height of the insulating sheath shall be 9.00.50 mm; see
diagram G in Figure 9.
4.2.2.3 After removing the insulating sheath, the thickness (t) of the plug body is shown in
4.3.1 The type and dimensions of plugs of the direct plug-in equipment shall comply with the
requirements of this document.
4.3.2 The insulating sheath (if any) of the plugs of the direct plug-in equipment shall cover the
root of the metal part of the exposed pin.
There shall be no gap between the insulating sheath and the equipment shell, causing the metal
root of the live pin to be exposed. If in doubt, check through the test in 5.4. During the test, the
probe shall not touch the live pin.
NOTE: this requirement only applies to the assessment of the plug part. The assessment of the
electric shock prevention of the whole machine is determined by the standard of the whole
machine.
4.3.3 When the plug of the direct plug-in equipment rotates as a whole, there should be locking
measures in the normal use position and shall satisfy the requirements for the plugs in this
document.
4.3.4 The plugs of the direct plug-in equipment shall be subject to the roller drop test of 5.5 in
normal use conditions.
After the test, the specimen shall not be damaged within the meaning of this document. After
calibration, it shall be normally plugged into a socket-outlet that complies with the requirements
of relevant standards, and shall satisfy:
---the metal pin shall not break;
---no parts are loose.
If the protection against electric shock is not affected, then, even small fragments fell off, for
example, the falling-off of the insulating sheath, it is still considered to be in compliance.
NOTE: damage to the surface layer and small dents that will not reduce the creepage distance or
electrical clearance below the values specified in 27.1 of GB/T 2099.1-2021 can be ignored.
4.3.5 The plug part of the direct plug-in equipment shall also comply with the requirements of
the applicable provisions on plugs in GB/T 2099.1-2021, including 14.23, 24.6, 24.8, 24.11,
28.1.3 and Chapter 30 in GB/T 2099.1-2021.
4.4 Socket-outlets
4.4.1 The distance K between the live plug bush of the socket-outlet and the mating surface is
as shown in Figure 11, and the value should not be less than the value specified in Table 1; and
shall pass the corresponding non-contact gauge tests in Figure 12, Figure 13 and Figure 14.
a) After the finished plug sample is clamped by a rigid stationary fixture, apply a force
to the pin to cause it to bend (as shown in Figure 26).
b) Before starting the test, the pin shall be straight. If there is any doubt whether the pin
is straight enough, the corresponding measuring gauges in Figure 16, Figure 17 and
Figure 18 can be used to check it.
c) The test force shall be applied at a distance of (14 0.5) mm from the plug mating
surface.
d) The direction of application of the test force shall be parallel to the mating surface of
the plug.
e) For phase line pins and neutral line pins, the test force shall be applied toward the
center point of the plug, then, return to the initial position.
f) The displacement distance of the pin from the point of force application shall be (7.5
0.3) mm, then, push the pin back to the starting point. Any “bounce” can be ignored.
NOTE 2: “bounce” means that when the force is removed, the pin returns to a position less than
the travel distance.
g) From the starting point of the displacement to the end point (7.5 mm 0.3 mm), then,
back to the starting point is one cycle (that is, one cycle is equal to two separate
bending and normalizing movements).
h) The deviation displacement speed shall be not greater than 50 mm/s, and there shall
be no intentional delay between consecutive movements in each cycle.
i) There shall be at least 10 s interval between each cycle.
j) The action time of a single cycle shall be not greater than 60 s.
k) The pin shall complete 20 complete cycles.
l) After the test, check the pin with normal or corrected t normal vision.
m) If in doubt, remove the pin from the plug and remove all insulation outside the pin,
then, conduct an inspection.
NOTE 3: in some cases, the break may be below the mating surface of the plug, or the insulation
may hold the broken pins together and maintain electrical contact.
5.4 After normally inserting the direct plug-in equipment into the socket-outlet, use the steel
probe shown in Figure 10 of GB/T 2099.1-2021 to apply a force of 1 N to the root of the pin,
and use an electrical indicator with a voltage between 40 V ~ 50 V to display the contact status
of relevant components.
5.5 Use 3 new samples to carry out the roller drop test in 24.3 of GB/T 2099.1-2021 in
accordance with the normal use conditions. If the direct plug-in equipment is equipped with a
flexible cable, then, the free length of the flexible cable extending from the direct plug-in
equipment is approximately 100 mm.
The number of drops is:
---100 times: if the weight of the specimen without the flexible cable does not exceed 100
g;
---50 times: if the weight of the specimen without the flexible cable exceeds 100 g, but
does not exceed 200 g;
---25 times: if the weight of the specimen without the flexible cable exceeds 200 g.
For plugs with pins with an insulating sheath, every 5 drops, they need to be checked through
the socket-outlet and manually corrected.
5.6 The methods of using the measuring gauges for the socket-outlet are as follows:
---the socket-outlet go gauge shall be able to be inserted into the jack on the socket-outlet
panel;
---the socket-outlet no-go gauge shall not be able to be inserted into the jack on the socket-
outlet panel;
---the socket-outlet contact gauge shall contact the live plug bush of the socket-outlet;
NOTE: as long as the contact gauge touches the live plug bush, it is deemed to satisfy the
requirements.
---the socket-outlet non-contact gauge shall not come into contact with the live plug bush
of the socket-outlet.
When using measuring gauges, if the socket-outlet has a protective door, it shall be disabled to
avoid affecting the test.
The insertion force of the measuring gauges shall be not greater than the maximum withdrawal
force in Table 16 of GB/T 2099.1-2021.
6 Implementation of Standard
6.1 For the types and dimensions of products that are produced or imported before the date of
implementation of this document, and that implement or refer to this document, the
implementation will start from the 13th month of the date of implementation of this document.
6.2 The requirement that the live pin of the plug shall have an insulating sheath (4.2.2) shall be
......
GB/T 1002-2021
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 29.120.30
CCS K 30
Replacing GB/T 1002-2008
Single Phase Plugs and Socket-Outlets for Household and
Similar Purposes – Types, Basic Parameters and Dimensions
ISSUED ON: OCTOBER 11, 2021
IMPLEMENTED ON: NOVEMBER 01, 2022
Issued by: State Administration for Market Regulation;
Standardization Administration of the People’s Republic of China.
Table of Contents
Foreword ... 3
1 Scope ... 6
2 Normative References ... 6
3 Terms and Definitions ... 6
4 Technical Requirements ... 6
5 Test Methods ... 8
Foreword
This Document was drafted as per the rules specified in GB/T 1.1-2020 Directives for
Standardization – Part 1: Rules for the Structure and Drafting of Standardizing Documents.
This Document replaced GB/T 1002-2008 Single Phase Plugs and Socket-Outlets for
Household and Similar Purposes - Types, Basic Parameters and Dimensions. Compared with
GB/T 1002-2008, the major technical changes of this Document are as follows besides the
structural adjustment and editorial modifications:
--- Delete the single-phase two-pole dual-purpose socket and its corresponding gauge (see
Figures 5, 17 and 18 in 2008 Edition);
--- Add the requirement that the live pin of the plug may be provided with an insulating
sheath (see 4.2.2 of this Edition);
--- Change the plug without grounding function, which has the same type, parameter and
dimension as the single-phase two-pole grounding plug in Figure 3 that can be equipped
with Class II equipment (see 4.2.3 of this Edition; 5.6 of 2008 Edition);
---Add the requirements that the distance between the live plug bush and the mating surface
of the socket should be no less than the value specified in Table 1 (see 4.3.1 of this
Edition);
--- Add the requirements that the distance between grounding plug bush and the mating
surface is no greater than the distance between live plug bush and mating surface of the
sane socket (see Figure 4) (see 4.3.2 of this Edition);
--- Add the use method of socket gauges (see 5.1.3 of this Edition);
--- Add Figure 5 schematic diagram for the edge of the plug, Figure 6 schematic diagram
for the height of the insulating sheath of the plug pin, and Figure 7 schematic diagram
for the distance between the live plug bush and the mating surface of the socket (see
Figures 5, 6 and 7 of this Edition);
--- Change the stop gauge to a single-pin stop gauge (see Figure 12 of this Edition; Figures
11 and 15 of 2008 Edition);
--- Combine the inner gauge and the outer gauge of a single-phase two-pole grounding plug
into a new gauge (see Figure 9 of this Edition; Figures 7 and 8 of 2008 Edition);
--- Change the length of the non-contact gauge (see Figures 13 and 14 of this Edition;
Figures 12 and 16 of 2008 Edition);
--- Add single-phase two-pole socket contact gauge and single-phase two-pole grounding
socket contact gauge (see Figures 15 and 16 of this Edition);
Single Phase Plugs and Socket-Outlets for Household and
Similar Purposes – Types, Basic Parameters and Dimensions
1 Scope
This Document specifies the types, basic parameters, dimensions and test methods of single-
phase plugs and sockets for household and similar purposes.
This Document applies to single-phase plugs and sockets with an AC frequency of 50Hz, a
rated voltage of 250V, and a rated current not exceeding 16A for use in households and similar
household environments.
2 Normative References
The provisions in following documents become the essential provisions of this Document
through reference in this Document. For the dated documents, only the versions with the dates
indicated are applicable to this Document; for the undated documents, only the latest version
(including all the amendments) is applicable to this Document.
GB/T 1184-1996 Geometrical Tolerancing - Geometrical Tolerance for Features without
Individual Tolerance Indications
GB/T 2099.1-2021 Plugs and Socket-Outlets for Household and Similar Purposes - Part 1:
General Requirements
GB/T 2900.70-2008 Electrotechnical Terminology - Electrical Accessories
3 Terms and Definitions
For the purposes of this Document, the terms and definitions given in GB/T 2900.70-2008 and
GB/T 2099.1-2021 apply.
4 Technical Requirements
4.1 General
4.1.1 Single-phase plugs and sockets for household and similar purposes are divided into two
basic types: two-pole ungrounding type and two-pole grounding type.
4.1.2 The type, basic parameters and dimensions of single-phase plugs and sockets for
household and similar purposes are as specified in Figures 1, 2, 3 and 4.
4.2 Plug
4.2.1 The shape of the plug is not specified, but the distance between the live pin and the edge
of the plug shall be no less than 6.5mm.
NOTE: If the mating surface of the plug is not a flat plane, the intersecting line with the outer surface of
the main body, offset by 1 mm from a plane passing through the highest point of the mating surface and
perpendicular to the axis of the pin, is regarded as the edge of the plug, as shown B value in Figure 5.
4.2.2 The live pins of plug may be provided with insulating sheaths. For the plug in Figure 1,
the height of the insulating sheath is (7 ± 0.5) mm; for the plug in Figure 3, the height of the
insulating sheath is (9 ± 0.5) mm, see schematic S in Figure 6. The outer dimension of the
insulating sheath of the plug cannot exceed the minimum size of the corresponding socket jack;
and the plug can be inserted into the socket smoothly.
Plugs with insulating sheaths shall also meet the requirements of 4.2.1.
NOTE: For plugs with insulating sheaths, patent issues may be involved.
4.2.3 Class-II equipment can be equipped with a single-phase two-pole grounding plug of the
same type, parameter and size as shown in Figure 3, but with no grounding function, and it shall
be made into a non-rewireable form. The position of the grounding pin in Figure 3 is used to
install the drive plate of protective door. The color of the driver plate is black, it is not connected
to the grounding wire, and the grounding symbol is not marked. It is only used as a drive device
to open the protective door when it is inserted into the socket.
4.3 Socket
4.3.1 The distance between the live plug bush and the mating surface of the socket shall be no
less than the value specified in Table 1, as indicated by K in Figure 7.
4.3.2 The distance between the grounding plug bush and the mating surface shall be no greater
than the distance between the live plug bush and the mating surface of the same socket (Figure
4).
5 Test Methods
5.1.1 To inspect the dimensions of single-phase plugs and sockets for household and similar
purposes, use the special gauges specified in Figures 8 ~ 16 and a vernier caliper with a division
value of 0.02mm to check, and measure the size of the rounding part of the end of the plug and
pin with an appropriate measuring tool. The surface roughness of these gauges is all , and
the hardness is Rockwell hardness HRC58~HRC62. The tolerance of form and position, such
as parallelism, perpendicularity and symmetry of the gauges are in accordance with the Grade-
H tolerances specified in GB/T 1184-1996.
5.1.2 The pins of the plug shall be able to pass the gauges shown in Figures 8 and 9. If the plug
pin is provided with an insulating sheath, the insulating sheath part does not need to pass the
gauges shown in Figures 8 and 9.
5.1.3 The use methods of socket gauges are as follows:
--- The general gauge of the socket shall be able to be inserted into the jack of the socket
panel;
--- The stop gauge of the socket shall not be able to be inserted into the jack of the socket
panel;
--- The contact gauge of the socket shall be able to touch the live plug bush of the socket;
--- The non-contact gauge of the socket shall not be able to touch the live plug bush of the
socket.
When using the gauge, if the socket has a protective door, it shall be disabled so as not to affect
the test.
The insertion force of the gauge shall be no greater than the maximum pull-out force in Table
16 of GB/T 2099.1-2021.
......
GB 1002-2008
Single phase plugs and socket-outlets for household and similar purposes.Types, basic parameters and dimensions
ICS 29.120.30
K30
National Standards of People's Republic of China
Replacing GB 1002-1996
Household and similar single-phase plugs and sockets
Types, basic parameters and dimensions
Posted 2008-09-24
2009-08-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
All the technical contents of this standard is mandatory.
This standard replaces and repealing GB 1002-1996 "household and similar purposes single-phase plug and socket type, basic parameters and dimensions."
The main differences between standard and GB 1002-1996 standard are.
--- Chapter 5 adds single-phase socket with plug electrode sets of mating distance from requirements;
--- Chapter 5 adds gauge insertion force requirements;
--- Chapter 5 increases the rated current of 16A polarized plug type provisions;
--- Single phase plugs and sockets to open the file from the dimensional tolerances effective numerical digits by three simplified 2-digit;
--- Increasing the number of inspection gauges, gauge overall modify the design tolerances and dimensions;
--- Increasing the single-phase pole sockets, single-phase bipolar with grounding receptacle dimensional inspection through maximum and minimum regulatory compliance through use;
--- Increasing the single-phase pole sockets, single-phase bipolar with grounding receptacle dimensional inspection is not in contact with the regulation;
--- Increase in single-phase two-poles socket round plug part only regulation.
This standard specifies only of household and similar single-phase plug and socket type, basic parameters and dimensions, technical requirements and test methods
Shall comply with GB 2099.1-2008.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the National Electric annex Standardization Technical Committee (SAC/TC67) centralized.
This standard was drafted. China Electric Apparatus Research Institute, Hangzhou Hongyan Electric Co., Ltd., Shenzhen Academy of Metrology and Quality Inspection, Beijing
Matsushita Electric Works Ltd., TCL International Electrical (Huizhou) Co., Ltd., Shunde Matsumoto Electrical Industrial Co., Ltd., Guangdong Lonon Electric Co.
Division, based Electric (Shenzhen) Co., Ltd., Legrand (Beijing) Electric Co., Ltd., Beijing ABB Low Voltage Electric Co., Ltd., Guangzhou Electrical Safety
Full detection, Clipsal Industries (Huizhou) Co., Ltd., Beijing breakthrough Electric Co., Ltd. Cixi City Electric Co., Chicago.
The main drafters of this standard. Luohuai Ping, towards a single blue tube Jie, Zhu Hongbin, Wang Ke Jian, Zhang Wenjie, Huang Chen north, Zhu Xinjie, Angui Long, easy weight,
Liu Liping, Wen Yong Choi, Lin Haiqing, Ruan Liping, Tang Yanlan Sun Magnum, Caiying Feng, Zhu Songtao, Yang Zhenjun.
This standard replaces the standards previously issued as follows.
--- GB 1002-1980, GB 1002-1996.
Household and similar single-phase plugs and sockets
Types, basic parameters and dimensions
1 Scope
This standard specifies the type of household and similar single-phase plugs and sockets, basic parameters and dimensions.
This standard applies to the family and home environment similar occasions, the AC frequency of 50Hz, rated voltage of 250V, rated current
More than 16A single phase plugs and fixed or portable socket-outlets.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 2900.70-2008 Electrotechnical terminology of electrical accessories (IEC 60050 442.? 1998, IDT)
GB 2099.1-2008 plug socket for household and similar purposes - Part 1. General requirements (IEC 60884 1.? 2006, MOD)
GB/T 1184-1996 shape and position tolerances without individual tolerance value (eqv ISO 2768 2.? 1989)
3 Terms and Definitions
GB/T 2900.70-2008 and GB 2099.1-2008 terms and definitions apply to this standard.
4 technical requirements and test methods
Technical requirements and test methods for household and similar purposes single-phase plugs and sockets shall comply with the provisions of GB 2099.1-2008.
5 Types, basic parameters and dimensions
5.1 Household and similar single-phase plugs and sockets are divided into two poles and two poles with grounding no grounding two basic types.
5.2 household and similar purposes in the form of a single-phase plug socket, basic parameters and dimensions shall comply with Figs. 1 to 5 and specified in Table 1 to Table 5.
5.3 Inspection of household and similar size single-phase plugs and sockets, use 6 to 18, Tables 6 to 18, those special gauge, indexing value
0.02mm vernier caliper pin end rounded portion size with an appropriate measuring measurement. Insertion force gauge should not exceed GB 2099.1-
2008 specified maximum pull-out force. These gauges all roughness, hardness of 58HRC ~ 62HRC, gauge parallel, vertical
Straightness and symmetry and other geometric tolerances according to GB/T 1184-1996 specified tolerance H-level.
5.4 plug shape not specified, but the plug pin distance from the edge of not less than 6.5mm.
5.5 single-phase socket plug sleeve (except the grounding plug cover) from the mating surface of the distance should not be less than a safe distance. These dimensions should test respectively
Figure 12, Table 12, Figure 16, Table 16 provided special gauge.
5.6 rated current of 16A single-phase bipolar plug without ground type, parameters and dimensions should be rated current 16A single-phase bipolar with grounding
Plug type, parameters and dimensions of the same, but it should be made non-rewirable plug. Ground pin position for the protection of the gate driver chip, the color is black, not
Contact wire, marked the ground symbol not only as plug and socket timely open the drive door protection.
1 single-phase polarized plug
Table 1 Single-phase basic parameters and dimensions polarized plug
The main dimensions of the basic parameters of polarized plug/mm
Rated voltage /
Rated current /
Open files from the connector pin size
6a 12.7 ± 0.14 1.5 0-0.1 6.4 0-0.22 16 ± 0.35 6.0 ± 1
10 12.7 ± 0.14 1.5 0-0.1 6.4 0-0.22 16 ± 0.35 6.0 ± 1
Only a non-rewirable plug for use.
It is end thickness suitable chamfering chamfering recommended length of up to 1mm.
2 single-phase pole sockets
Table 2 socket single-phase bipolar basic parameters and dimensions
The main dimensions of the basic parameters of the poles socket/mm
Rated voltage /
Rated current /
Open files from the socket jack Dimensions
FTB
250 10 12.7 ± 0.14 2.0 + 0.140 7.3 + 0.220
3 single-phase bipolar with grounding plug
Table 3 single-phase bipolar with grounding plug basic parameters and dimensions
The main dimensions of the basic parameters of the poles with grounded plug/mm
Rated voltage /
Rated current /
Open files from the connector pin size
6a 10.3 ± 0.14 7.9 ± 0.11 120 ° ± 30'1.5 0-0.10 6.4 0-0.22 21 ± 0.42 18 ± 0.35 6.0 ± 1
10 10.3 ± 0.14 7.9 ± 0.11 120 ° ± 30'1.5 0-0.10 6.4 0-0.22 21 ± 0.42 18 ± 0.35 6.0 ± 1
16c 11.1 ± 0.14 9.5 ± 0.11 120 ° ± 30'1.8 0-0.10 8.1 0-0.22 21 ± 0.42 18 ± 0.35 6.0 ± 1
Only a non-rewirable plug for use.
bC, E end thickness suitable chamfering chamfering recommended length of up to 1mm.
c16A2P used only for non-rewirable plug
4 single-phase bipolar with grounding outlet
Basic parameters and dimensions of 4 single-phase bipolar with grounding socket
The main dimensions of the basic parameters of the poles with ground socket/mm
Rated voltage /
Rated current /
Open files from the socket jack Dimensions
AFJTB
10 10.3 ± 0.14 7.9 ± 0.11 120 ° ± 30 '2.0 + 0.140 7.3 + 0.220
16 11.1 ± 0.14 9.5 ± 0.11 120 ° ± 30 '2.4 + 0.140 9.0 + 0.220
5 single-phase two-poles socket
Table 5 single-phase two-poles socket basic parameters and dimensions
The basic parameters of bipolar dual socket main dimensions/mm
Rated voltage /
Rated current /
Open files from the socket jack Dimensions
F1 F2 TBR
250 10 12.7 ± 0.14 19 ± 0.17 2.0 + 0.140 7.3 + 0.220 2.8 + 0.140
Note. R1 is any rounding.
6 Single image with polarized plug gauge
Table 6 single-phase polarized plug gauge size
The basic parameters of polarized plug gauge dimensions/mm
Rated voltage /
Rated current /
6 12.7 ± 0.02 1.68 0-0.02 6.45 0-0.05 30 ± 0.20 10
10 12.7 ± 0.02 1.68 0-0.02 6.45 0-0.05 30 ± 0.20 10
Figure 7 gauge grounding plug within a single phase with two poles
Table grounding plug gauge dimension within 7 with single-phase bipolar
With grounding plug on the basic parameters within the gauge dimensions/mm
Rated voltage /
Rated current /
6 10.16 0-0.02 7.79 0-0.02 120 ° ± 10 '1.52 0-0.02 6.45 0-0.05 10
10 10.16 0-0.02 7.79 0-0.02 120 ° ± 10 '1.52 0-0.02 6.45 0-0.05 10
16 10.96 0-0.02 9.39 0-0.02 120 ° ± 10 '1.82 0-0.02 8.15 0-0.05 10
, B pg
8 grounding plug external gauge single-phase diagram with two poles
Table 8 grounding plug external gauge with single-phase bipolar
The basic parameters of the outer poles with grounded plug gauge size/mm
Rated voltage /
Rated current /
10 10.44 + 0.020 8.0 + 0.020 120 ° ± 10 '1.52 0-0.02 6.45 0-0.05 50 ± 0.3 10
16 11.24 + 0.020 9.61 + 0.020 120 ° ± 10 '1.82 0-0.02 8.15 0-0.05 55 ± 0.3 10
, B pg
9 single-phase pole sockets maximum-gauge
Table 9 single-phase pole sockets maximum-gauge size
The basic parameters of the maximum pass regulation pole sockets Dimensions/mm
Rated voltage /
Rated current /
Fsg Tsg Bsg Wsg Easg R
250 10 12.84 0-0.02 1.5 0-0.02 6.4 0-0.05 30 ± 0.2 16 0-0.1 6.0 ± 0.5
aEsg chamfer end thickness of 1mm.
10 single-phase pole sockets minimum-gauge
Table 10 single-phase pole sockets the size of the minimum-gauge
The basic parameters of the minimum-gauge pole sockets Dimensions/mm
Rated voltage /
Rated current /
Fsg Tsg Bsg Wsg Easg R
250 10 12.56 + 0.020 1.5 0-0.02 6.4 0-0.05 30 ± 0.2 16 0-0.1 6.0 ± 0.5
aEsg chamfer end thickness of 1mm.
Regulations only 11 single-phase pole sockets
Table 11 single-phase pole sockets only regulation size
The basic parameters of the bipolar socket only regulation size/mm
Rated voltage /
Rated current /
Fsg Tsg Bsg Wsg Esg
250 10 12.7 ± 0.02 2.15 + 0.020 7.6 + 0.050 30 ± 0.2 10
12 single-phase pole sockets are not in contact regulations
Table 12 does not contact the single-phase pole sockets the size of Regulation
The basic parameters of the bipolar socket does not contact the gauge size/mm
Rated voltage /
Rated current /
Fsg Tsg Bsg Wsg Esg
250 10 12.7 ± 0.02 1.5 0-0.02 6.4 0-0.05 30 ± 0.2 8.45 0-0.05
13 single-phase bipolar with grounding outlet maximum-gauge
Table 13 Single-phase bipolar with grounding outlet through regulation maximum size
The basic parameters of the poles with a grounded outlet maximum-gauge size/mm
Rated voltage /
Rated current /
Asg Fsg Jsg Tsg Bsg Wsg Casg Easg R
10 10.44 0-0.02 8.0 0-0.02 120 ° ± 10'1.5 0-0.02 6.4 0-0.05 35 ± 0.2 21 0-0.1 18 0-0.1 6.0 ± 0.5
16 11.24 0-0.02 9.61 0-0.02 120 ° ± 10'1.8 0-0.02 8.1 0-0.05 40 ± 0.2 21 0-0.1 18 0-0.1 6.0 ± 0.5
aCsg, Esg chamfered end thickness of 1mm.
14 single-phase bipolar with grounding outlet minimum-gauge
Table 14 Single-phase bipolar with grounding outlet pass minimum size regulation
The basic parameters of the poles with a grounded outlet pass regulatory minimum size/mm
Rated voltage /
Rated current /
Asg Fsg Jsg Tsg Bsg Wsg Casg Easg R
10 10.16 + 0.020 7.79 + 0.020 120 ° ± 10'1.5 0-0.02 6.4 0-0.05 35 ± 0.2 21 0-0.1 18 0-0.1 6.0 ± 0.5
16 10.96 + 0.020 9.39 + 0.020 120 ° ± 10'1.8 0-0.02 8.1 0-0.05 40 ± 0.2 21 0-0.1 18 0-0.1 6.0 ± 0.5
aCsg, Esg chamfered end thickness of 1mm.
Regulations only 15 single-phase bipolar with grounding outlet
Table 15 Single-phase bipolar with grounding receptacle only regulation size
The basic parameters of the poles with a grounded outlet only regulation size/mm
Rated voltage /
Rated current /
Asg Fsg Jsg Tsg Bsg Wsg Csg Esg
10 10.3 ± 0.027.9 ± 0.02 120 ° ± 10 '2.15 + 0.020 7.6 + 0.050 35 ± 0.2 10 10
16 11.1 ± 0.029.5 ± 0.02 120 ° ± 10 '2.55 + 0.020 9.3 + 0.050 35 ± 0.2 10 10
16 single-phase poles are not in contact with the ground receptacle Regulation
Table 16 Single-phase bipolar with grounding outlet does not contact the gauge size
The basic parameters of the poles is not in contact with the ground receptacle regulation size/mm
Rated voltage /
Rated current /
Asg Fsg Jsg Tsg Bsg Wsg Casg Esg R
10 10.3 ± 0.027.9 ± 0.02 120 ° ± 10'1.5 0-0.02 6.4 0-0.0535 ± 0.2 21 0-0.1 10.35 0-0.05 6.0 ± 0.5
16 11.1 ± 0.029.5 ± 0.02 120 ° ± 10'1.8 0-0.02 8.1 0-0.0535 ± 0.2 21 0-0.1 10.35 0-0.05 6.0 ± 0.5
aCsg chamfer end thickness of 1mm.
17 single-phase two-poles socket round plug part through regulation
Table 17 dual-socket single-phase bipolar circular interpolation section through regulation size
The basic parameters of bipolar double round plug socket part through regulation size/mm
Rated voltage /
Rated current /
F2sg Dsg Wsg Esg SR
250 10 19 ± 0.02 4.8 0-0.05 30 ± 0.2 19.5 0-0.1 6.0 ± 0.5
Figure 18 Single-phase dual-socket bipolar circular interpolation section only regulation
Table 18 dual-socket single-phase bipolar circular interpolation section only regulation size
The basic parameters of bipolar double round plug socket part only regulation size/mm
Rated voltage /
Rated current /
F2sg Dsg Wsg Esg
250 10 19 ± 0.02 5.9 + 0.020 30 ± 0.2 10
......
Standard ID | GB 1002-2024 (GB1002-2024) | Description (Translated English) | Single phase plugs and socket-outlets for household and similar purposes - Types, basic parameters and dimensions | Sector / Industry | National Standard | Classification of Chinese Standard | K30 | Classification of International Standard | 29.120.30 | Word Count Estimation | 30,353 | Date of Issue | 2024-07-24 | Date of Implementation | 2025-08-01 | Older Standard (superseded by this standard) | GB/T 1002-2021 | Administrative Organization | Ministry of Industry and Information Technology of the People Republic of China | Proposing organization | Ministry of Industry and Information Technology of the People's Republic of China | Issuing agency(ies) | State Administration for Market Regulation, National Standardization Administration | Standard ID | GB/T 1002-2021 (GB/T1002-2021) | Description (Translated English) | Single phase plugs and socket-outlets for household and similar purposes -- Types, basic parameters and dimensions | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | K30 | Classification of International Standard | 29.120.30 | Word Count Estimation | 15,125 | Date of Issue | 2021-10-11 | Date of Implementation | 2022-11-01 | Older Standard (superseded by this standard) | GB/T 1002-2008 | Drafting Organization | China National Electrical Equipment Research Institute Co., Ltd., Hangzhou Hongyan Electric Co., Ltd., Zhejiang Chint Construction Electric Co., Ltd., Bull Group Co., Ltd., Zhejiang Delixi International Electric Co., Ltd., Legrand Intelligent Electric (Huizhou) Co., Ltd., Panasonic Electric Machinery (Beijing) Co., Ltd., Weikai Testing Technology Co., Ltd., Feidiao Electric Group Co., Ltd., Qingmi (Beijing) Technology Co., Ltd., Jiangsu Tongling Technology Co., Ltd., Panasonic Information Instrument (Shanghai) Co., Ltd., Haige Electric ( Huizhou) Co., Ltd., Ningbo Boxing King Electric Co., Ltd., Zhongshan Jiadi Electric Co., Ltd., Honeywell Automation Control (China) Co., Ltd., Taili Industrial Co., Ltd., Boshuo Technology (Jiangxi) Co., Ltd., Jiaxing Weikai Testing Technology Co., Ltd., Guangdong Futian Electric Co., Ltd. | Administrative Organization | National Electrical Accessories Standardization Technical Committee (SAC/TC 67) | Regulation (derived from) | National Standard Announcement No. 12 of 2021 | Proposing organization | China Electrical Equipment Industry Association | Issuing agency(ies) | State Administration for Market Regulation, National Standardization Administration | Standard ID | GB 1002-2008 (GB1002-2008) | Description (Translated English) | [GB/T 1002-2008] Single phase plugs and socket-outlets for household and similar purposes. Types, basic parameters and dimensions [Quasi-Official / Academic version - translated by Chinese Institute] | Sector / Industry | National Standard | Classification of Chinese Standard | K30 | Classification of International Standard | 29.120.30 | Word Count Estimation | 14,167 | Date of Issue | 2008-09-24 | Date of Implementation | 2009-08-01 | Older Standard (superseded by this standard) | GB 1002-1996 | Quoted Standard | GB/T 2900.70-2008; GB 2099.1-2008; GB/T 1184-1996 | Drafting Organization | China Electric Apparatus Research Institute | Administrative Organization | National Standardization Technical Committee of electrical accessories | Regulation (derived from) | Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall) | Proposing organization | China Electrical Equipment Industry Association | Issuing agency(ies) | Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China | Summary | This Chinese standard specifies the household and similar purposes the type of single-phase plugs and sockets, basic parameters and dimensions. This standard applies to home and family environment similar occasions, the AC frequency of 50Hz, rated voltage of 250V, rated current not exceeding 16A single phase plugs and fixed or portable socket-outlets. |
|