HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (1 Dec 2024)

GB 1002-2024 Related PDF English (GB/T 1002-2021, GB 1002-2008)

GB 1002-2024 (GB1002-2024) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
GB 1002-2024English485 Add to Cart 0-9 seconds. Auto delivery. Single phase plugs and socket-outlets for household and similar purposes - Types, basic parameters and dimensions GB 1002-2024 Valid GB 1002-2024
GB/T 1002-2021English215 Add to Cart 0-9 seconds. Auto delivery. Single phase plugs and socket-outlets for household and similar purposes -- Types, basic parameters and dimensions GB/T 1002-2021 Valid GBT 1002-2021
GB 1002-2008English85 Add to Cart 0-9 seconds. Auto delivery. [GB/T 1002-2008] Single phase plugs and socket-outlets for household and similar purposes. Types, basic parameters and dimensions [Quasi-Official / Academic version - translated by Chinese Institute] GB 1002-2008 Obsolete GB 1002-2008
GB 1002-1996English85 Add to Cart 0-9 seconds. Auto delivery. Single phase plugs and socket-outlets for household and similar purposes. Types, basic parameters and dimensions GB 1002-1996 Obsolete GB 1002-1996
GB 1002-1980EnglishRFQ ASK 3 days Types, basic parameters and dimensions of single phase plugs and sockets GB 1002-1980 Obsolete GB 1002-1980
Preview this PDF: GB 1002-2024



GB 1002-2024 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 29.120.30 CCS K 30 Replacing GB/T 1002-2021 Single Phase Plugs and Socket-outlets for Household and Similar Purposes - Types, Basic Parameters and Dimensions ISSUED ON: JULY 24, 2024 IMPLEMENTED ON: AUGUST 1, 2025 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3 1 Scope ... 5 2 Normative References ... 5 3 Terms and Definitions ... 6 4 Technical Requirements ... 6 5 Test Methods ... 10 6 Implementation of Standard ... 12 Bibliography ... 30 Single Phase Plugs and Socket-outlets for Household and Similar Purposes - Types, Basic Parameters and Dimensions 1 Scope This document specifies the types, basic parameters and dimensions of single-phase plugs and socket-outlets for household and similar purposes, and describes the corresponding test methods. This document is applicable to single phase plugs and socket-outlets for household and similar purposes, with an AC frequency of 50 Hz, a rated voltage of 250 V and a rated current not exceeding 32 A. NOTE: examples of products, to which, the types and dimensions of this document are applicable include: ---socket-outlets used in household scenarios; ---plugs provided with electrical equipment; ---plugs of direct plug-in equipment; ---fixed integrated AC-powered socket-outlets with a rated voltage of 220 V and for conductive charging of electric vehicles; ---charging socket-outlets in centralized charging facilities for electric bicycles and electric motorcycles. 2 Normative References The contents of the following documents constitute indispensable clauses of this document through the normative references in the text. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document. GB/T 1184-1996 Geometrical Tolerancing - Geometrical Tolerance for Features without Individual Tolerance Indications GB/T 2099.1-2021 Plugs and Socket-outlets for Household and Similar Purposes - Part 1: General Requirements GB/T 2099.3 Plugs and Socket-outlets for Household and Similar Purposes - Part 2-5: Particular Requirements for Adaptors GB/T 2900.70-2008 Electrotechnical Terminology - Electrical Accessories 3 Terms and Definitions The terms and definitions defined in GB/T 2900.70-2008 and GB/T 2099.1-2021, and the following are applicable to this document. 3.1 direct plug-in equipment An equipment, in which, the power plug and the equipment shell constitute an integral part. NOTE: examples of direct plug-in equipment include shavers with rechargeable batteries, night lights mounted on electrical socket-outlets, plug-in transformers and power adapters, etc. [source: GB 4943.1-2022, 3.3.3.1, modified] 4 Technical Requirements 4.1 General Requirements 4.1.1 Single phase plugs and socket-outlets for household and similar purposes are divided into two basic types: two-pole ungrounded and two-pole grounded. 4.1.2 The types, basic parameters and dimensions of the single-phase plugs and socket-outlets for household and similar purposes shall comply with the provisions of Figure 1 ~ Figure 6. 4.1.3 In addition to fixed socket-outlets, for mobile (portable) socket-outlets, converters and appliance socket-outlets, arrangement and combination of the socket jack in Figure 2 and the socket jack in Figure 4 are allowed, but the socket jack in Figure 2 and the socket jack in Figure 4 shall not overlap or be shared with each other. Figure 7 provides a schematic diagram. NOTE 1: the arrangement and combination of socket jack here cannot be comprehended as adding corresponding plug types. NOTE 2: the schematic diagram in Figure 7 does not exclude other forms of combinations. NOTE 3: examples of fixed socket-outlets include wall-mounted socket-outlets. 4.1.4 The position of the plug bush of two-pole grounded socket-outlets shall be such that when facing the socket-outlets, the ground wire (E pole) is at the top, the neutral wire (N pole) is on the left, and the phase wire (L pole) is on the right. The position of the pin of two-pole grounded plugs shall correspond to that of the socket-outlets. 4.1.5 The single pin of a plug shall not undergo axial rotation that changes the type and position. NOTE: axial rotation, for example, by twisting the pin, changes the two parallel-arranged pins of the plug in Figure 1 to the position of the phase pole and neutral pole arrangement shown in Figure 3. 4.1.6 The strength of the inner frame of the fixed pin of non-rewireable plug shall be able to ensure the stability of the pin size, and the type and dimensions shall comply with the requirements of the corresponding dimensional drawings. 4.2 Plugs 4.2.1 Plug shape The shape of the plugs is not specified, but the distance between the root of the live pin of the plugs and the edge of the plugs shall not be less than 6.5 mm. NOTE 1: if there is an insulating sheath, then, take the metal pin after the insulating sheath is peeled off as the root. NOTE 2: if the mating surface of the plug is not a plane, then, from a plane that passes through the highest point of the mating surface and is perpendicular to the axis of the plug, the line that is offset 1 mm towards the direction of the plug body and intersects the surface of the body is regarded as the edge of the plug. An example is the B value in Figure 8. The protruding part of the plug mating surface shall not exceed 0.5 mm. The length of the plug pin shall be measured from the vertical plane of the pin at the highest point of the plug mating surface, till the top of the pin. NOTE 3: examples of “protrusions” include the electrical parameters and trademarks, etc. formed by the injection molding of the plug mating surface, or other appearance structures that may affect the plug mating. NOTE 4: for plugs with functional parts on the mating surface, when inserted into the socket-outlet, the gap between the plug mating surface and the socket-outlet surface does not exceed 1 mm. NOTE 5: the length of the plug pin is considered to be the effective length of the metal pin part inserted into the socket-outlet. 4.2.2 Insulating sheath of pin 4.2.2.1 The live pin of the plug shall have an insulating sheath. NOTE: the insulating sheath can adopt processes, such as: insert injection molding and adhesive backing, etc. 4.2.2.2 For the plug in Figure 1, the height of the insulating sheath shall be 7.0൅0.50 mm; for the plug in Figure 3 and Figure 5, the height of the insulating sheath shall be 9.0൅0.50 mm; see diagram G in Figure 9. 4.2.2.3 After removing the insulating sheath, the thickness (t) of the plug body is shown in 4.3.1 The type and dimensions of plugs of the direct plug-in equipment shall comply with the requirements of this document. 4.3.2 The insulating sheath (if any) of the plugs of the direct plug-in equipment shall cover the root of the metal part of the exposed pin. There shall be no gap between the insulating sheath and the equipment shell, causing the metal root of the live pin to be exposed. If in doubt, check through the test in 5.4. During the test, the probe shall not touch the live pin. NOTE: this requirement only applies to the assessment of the plug part. The assessment of the electric shock prevention of the whole machine is determined by the standard of the whole machine. 4.3.3 When the plug of the direct plug-in equipment rotates as a whole, there should be locking measures in the normal use position and shall satisfy the requirements for the plugs in this document. 4.3.4 The plugs of the direct plug-in equipment shall be subject to the roller drop test of 5.5 in normal use conditions. After the test, the specimen shall not be damaged within the meaning of this document. After calibration, it shall be normally plugged into a socket-outlet that complies with the requirements of relevant standards, and shall satisfy: ---the metal pin shall not break; ---no parts are loose. If the protection against electric shock is not affected, then, even small fragments fell off, for example, the falling-off of the insulating sheath, it is still considered to be in compliance. NOTE: damage to the surface layer and small dents that will not reduce the creepage distance or electrical clearance below the values specified in 27.1 of GB/T 2099.1-2021 can be ignored. 4.3.5 The plug part of the direct plug-in equipment shall also comply with the requirements of the applicable provisions on plugs in GB/T 2099.1-2021, including 14.23, 24.6, 24.8, 24.11, 28.1.3 and Chapter 30 in GB/T 2099.1-2021. 4.4 Socket-outlets 4.4.1 The distance K between the live plug bush of the socket-outlet and the mating surface is as shown in Figure 11, and the value should not be less than the value specified in Table 1; and shall pass the corresponding non-contact gauge tests in Figure 12, Figure 13 and Figure 14. a) After the finished plug sample is clamped by a rigid stationary fixture, apply a force to the pin to cause it to bend (as shown in Figure 26). b) Before starting the test, the pin shall be straight. If there is any doubt whether the pin is straight enough, the corresponding measuring gauges in Figure 16, Figure 17 and Figure 18 can be used to check it. c) The test force shall be applied at a distance of (14  0.5) mm from the plug mating surface. d) The direction of application of the test force shall be parallel to the mating surface of the plug. e) For phase line pins and neutral line pins, the test force shall be applied toward the center point of the plug, then, return to the initial position. f) The displacement distance of the pin from the point of force application shall be (7.5  0.3) mm, then, push the pin back to the starting point. Any “bounce” can be ignored. NOTE 2: “bounce” means that when the force is removed, the pin returns to a position less than the travel distance. g) From the starting point of the displacement to the end point (7.5 mm  0.3 mm), then, back to the starting point is one cycle (that is, one cycle is equal to two separate bending and normalizing movements). h) The deviation displacement speed shall be not greater than 50 mm/s, and there shall be no intentional delay between consecutive movements in each cycle. i) There shall be at least 10 s interval between each cycle. j) The action time of a single cycle shall be not greater than 60 s. k) The pin shall complete 20 complete cycles. l) After the test, check the pin with normal or corrected t normal vision. m) If in doubt, remove the pin from the plug and remove all insulation outside the pin, then, conduct an inspection. NOTE 3: in some cases, the break may be below the mating surface of the plug, or the insulation may hold the broken pins together and maintain electrical contact. 5.4 After normally inserting the direct plug-in equipment into the socket-outlet, use the steel probe shown in Figure 10 of GB/T 2099.1-2021 to apply a force of 1 N to the root of the pin, and use an electrical indicator with a voltage between 40 V ~ 50 V to display the contact status of relevant components. 5.5 Use 3 new samples to carry out the roller drop test in 24.3 of GB/T 2099.1-2021 in accordance with the normal use conditions. If the direct plug-in equipment is equipped with a flexible cable, then, the free length of the flexible cable extending from the direct plug-in equipment is approximately 100 mm. The number of drops is: ---100 times: if the weight of the specimen without the flexible cable does not exceed 100 g; ---50 times: if the weight of the specimen without the flexible cable exceeds 100 g, but does not exceed 200 g; ---25 times: if the weight of the specimen without the flexible cable exceeds 200 g. For plugs with pins with an insulating sheath, every 5 drops, they need to be checked through the socket-outlet and manually corrected. 5.6 The methods of using the measuring gauges for the socket-outlet are as follows: ---the socket-outlet go gauge shall be able to be inserted into the jack on the socket-outlet panel; ---the socket-outlet no-go gauge shall not be able to be inserted into the jack on the socket- outlet panel; ---the socket-outlet contact gauge shall contact the live plug bush of the socket-outlet; NOTE: as long as the contact gauge touches the live plug bush, it is deemed to satisfy the requirements. ---the socket-outlet non-contact gauge shall not come into contact with the live plug bush of the socket-outlet. When using measuring gauges, if the socket-outlet has a protective door, it shall be disabled to avoid affecting the test. The insertion force of the measuring gauges shall be not greater than the maximum withdrawal force in Table 16 of GB/T 2099.1-2021. 6 Implementation of Standard 6.1 For the types and dimensions of products that are produced or imported before the date of implementation of this document, and that implement or refer to this document, the implementation will start from the 13th month of the date of implementation of this document. 6.2 The requirement that the live pin of the plug shall have an insulating sheath (4.2.2) shall be ......


GB/T 1002-2021 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 29.120.30 CCS K 30 Replacing GB/T 1002-2008 Single Phase Plugs and Socket-Outlets for Household and Similar Purposes – Types, Basic Parameters and Dimensions ISSUED ON: OCTOBER 11, 2021 IMPLEMENTED ON: NOVEMBER 01, 2022 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3 1 Scope ... 6 2 Normative References ... 6 3 Terms and Definitions ... 6 4 Technical Requirements ... 6 5 Test Methods ... 8 Foreword This Document was drafted as per the rules specified in GB/T 1.1-2020 Directives for Standardization – Part 1: Rules for the Structure and Drafting of Standardizing Documents. This Document replaced GB/T 1002-2008 Single Phase Plugs and Socket-Outlets for Household and Similar Purposes - Types, Basic Parameters and Dimensions. Compared with GB/T 1002-2008, the major technical changes of this Document are as follows besides the structural adjustment and editorial modifications: --- Delete the single-phase two-pole dual-purpose socket and its corresponding gauge (see Figures 5, 17 and 18 in 2008 Edition); --- Add the requirement that the live pin of the plug may be provided with an insulating sheath (see 4.2.2 of this Edition); --- Change the plug without grounding function, which has the same type, parameter and dimension as the single-phase two-pole grounding plug in Figure 3 that can be equipped with Class II equipment (see 4.2.3 of this Edition; 5.6 of 2008 Edition); ---Add the requirements that the distance between the live plug bush and the mating surface of the socket should be no less than the value specified in Table 1 (see 4.3.1 of this Edition); --- Add the requirements that the distance between grounding plug bush and the mating surface is no greater than the distance between live plug bush and mating surface of the sane socket (see Figure 4) (see 4.3.2 of this Edition); --- Add the use method of socket gauges (see 5.1.3 of this Edition); --- Add Figure 5 schematic diagram for the edge of the plug, Figure 6 schematic diagram for the height of the insulating sheath of the plug pin, and Figure 7 schematic diagram for the distance between the live plug bush and the mating surface of the socket (see Figures 5, 6 and 7 of this Edition); --- Change the stop gauge to a single-pin stop gauge (see Figure 12 of this Edition; Figures 11 and 15 of 2008 Edition); --- Combine the inner gauge and the outer gauge of a single-phase two-pole grounding plug into a new gauge (see Figure 9 of this Edition; Figures 7 and 8 of 2008 Edition); --- Change the length of the non-contact gauge (see Figures 13 and 14 of this Edition; Figures 12 and 16 of 2008 Edition); --- Add single-phase two-pole socket contact gauge and single-phase two-pole grounding socket contact gauge (see Figures 15 and 16 of this Edition); Single Phase Plugs and Socket-Outlets for Household and Similar Purposes – Types, Basic Parameters and Dimensions 1 Scope This Document specifies the types, basic parameters, dimensions and test methods of single- phase plugs and sockets for household and similar purposes. This Document applies to single-phase plugs and sockets with an AC frequency of 50Hz, a rated voltage of 250V, and a rated current not exceeding 16A for use in households and similar household environments. 2 Normative References The provisions in following documents become the essential provisions of this Document through reference in this Document. For the dated documents, only the versions with the dates indicated are applicable to this Document; for the undated documents, only the latest version (including all the amendments) is applicable to this Document. GB/T 1184-1996 Geometrical Tolerancing - Geometrical Tolerance for Features without Individual Tolerance Indications GB/T 2099.1-2021 Plugs and Socket-Outlets for Household and Similar Purposes - Part 1: General Requirements GB/T 2900.70-2008 Electrotechnical Terminology - Electrical Accessories 3 Terms and Definitions For the purposes of this Document, the terms and definitions given in GB/T 2900.70-2008 and GB/T 2099.1-2021 apply. 4 Technical Requirements 4.1 General 4.1.1 Single-phase plugs and sockets for household and similar purposes are divided into two basic types: two-pole ungrounding type and two-pole grounding type. 4.1.2 The type, basic parameters and dimensions of single-phase plugs and sockets for household and similar purposes are as specified in Figures 1, 2, 3 and 4. 4.2 Plug 4.2.1 The shape of the plug is not specified, but the distance between the live pin and the edge of the plug shall be no less than 6.5mm. NOTE: If the mating surface of the plug is not a flat plane, the intersecting line with the outer surface of the main body, offset by 1 mm from a plane passing through the highest point of the mating surface and perpendicular to the axis of the pin, is regarded as the edge of the plug, as shown B value in Figure 5. 4.2.2 The live pins of plug may be provided with insulating sheaths. For the plug in Figure 1, the height of the insulating sheath is (7 ± 0.5) mm; for the plug in Figure 3, the height of the insulating sheath is (9 ± 0.5) mm, see schematic S in Figure 6. The outer dimension of the insulating sheath of the plug cannot exceed the minimum size of the corresponding socket jack; and the plug can be inserted into the socket smoothly. Plugs with insulating sheaths shall also meet the requirements of 4.2.1. NOTE: For plugs with insulating sheaths, patent issues may be involved. 4.2.3 Class-II equipment can be equipped with a single-phase two-pole grounding plug of the same type, parameter and size as shown in Figure 3, but with no grounding function, and it shall be made into a non-rewireable form. The position of the grounding pin in Figure 3 is used to install the drive plate of protective door. The color of the driver plate is black, it is not connected to the grounding wire, and the grounding symbol is not marked. It is only used as a drive device to open the protective door when it is inserted into the socket. 4.3 Socket 4.3.1 The distance between the live plug bush and the mating surface of the socket shall be no less than the value specified in Table 1, as indicated by K in Figure 7. 4.3.2 The distance between the grounding plug bush and the mating surface shall be no greater than the distance between the live plug bush and the mating surface of the same socket (Figure 4). 5 Test Methods 5.1.1 To inspect the dimensions of single-phase plugs and sockets for household and similar purposes, use the special gauges specified in Figures 8 ~ 16 and a vernier caliper with a division value of 0.02mm to check, and measure the size of the rounding part of the end of the plug and pin with an appropriate measuring tool. The surface roughness of these gauges is all , and the hardness is Rockwell hardness HRC58~HRC62. The tolerance of form and position, such as parallelism, perpendicularity and symmetry of the gauges are in accordance with the Grade- H tolerances specified in GB/T 1184-1996. 5.1.2 The pins of the plug shall be able to pass the gauges shown in Figures 8 and 9. If the plug pin is provided with an insulating sheath, the insulating sheath part does not need to pass the gauges shown in Figures 8 and 9. 5.1.3 The use methods of socket gauges are as follows: --- The general gauge of the socket shall be able to be inserted into the jack of the socket panel; --- The stop gauge of the socket shall not be able to be inserted into the jack of the socket panel; --- The contact gauge of the socket shall be able to touch the live plug bush of the socket; --- The non-contact gauge of the socket shall not be able to touch the live plug bush of the socket. When using the gauge, if the socket has a protective door, it shall be disabled so as not to affect the test. The insertion force of the gauge shall be no greater than the maximum pull-out force in Table 16 of GB/T 2099.1-2021. ......


GB 1002-2008 Single phase plugs and socket-outlets for household and similar purposes.Types, basic parameters and dimensions ICS 29.120.30 K30 National Standards of People's Republic of China Replacing GB 1002-1996 Household and similar single-phase plugs and sockets Types, basic parameters and dimensions Posted 2008-09-24 2009-08-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Foreword All the technical contents of this standard is mandatory. This standard replaces and repealing GB 1002-1996 "household and similar purposes single-phase plug and socket type, basic parameters and dimensions." The main differences between standard and GB 1002-1996 standard are. --- Chapter 5 adds single-phase socket with plug electrode sets of mating distance from requirements; --- Chapter 5 adds gauge insertion force requirements; --- Chapter 5 increases the rated current of 16A polarized plug type provisions; --- Single phase plugs and sockets to open the file from the dimensional tolerances effective numerical digits by three simplified 2-digit; --- Increasing the number of inspection gauges, gauge overall modify the design tolerances and dimensions; --- Increasing the single-phase pole sockets, single-phase bipolar with grounding receptacle dimensional inspection through maximum and minimum regulatory compliance through use; --- Increasing the single-phase pole sockets, single-phase bipolar with grounding receptacle dimensional inspection is not in contact with the regulation; --- Increase in single-phase two-poles socket round plug part only regulation. This standard specifies only of household and similar single-phase plug and socket type, basic parameters and dimensions, technical requirements and test methods Shall comply with GB 2099.1-2008. The standard proposed by China Electrical Equipment Industrial Association. This standard by the National Electric annex Standardization Technical Committee (SAC/TC67) centralized. This standard was drafted. China Electric Apparatus Research Institute, Hangzhou Hongyan Electric Co., Ltd., Shenzhen Academy of Metrology and Quality Inspection, Beijing Matsushita Electric Works Ltd., TCL International Electrical (Huizhou) Co., Ltd., Shunde Matsumoto Electrical Industrial Co., Ltd., Guangdong Lonon Electric Co. Division, based Electric (Shenzhen) Co., Ltd., Legrand (Beijing) Electric Co., Ltd., Beijing ABB Low Voltage Electric Co., Ltd., Guangzhou Electrical Safety Full detection, Clipsal Industries (Huizhou) Co., Ltd., Beijing breakthrough Electric Co., Ltd. Cixi City Electric Co., Chicago. The main drafters of this standard. Luohuai Ping, towards a single blue tube Jie, Zhu Hongbin, Wang Ke Jian, Zhang Wenjie, Huang Chen north, Zhu Xinjie, Angui Long, easy weight, Liu Liping, Wen Yong Choi, Lin Haiqing, Ruan Liping, Tang Yanlan Sun Magnum, Caiying Feng, Zhu Songtao, Yang Zhenjun. This standard replaces the standards previously issued as follows. --- GB 1002-1980, GB 1002-1996. Household and similar single-phase plugs and sockets Types, basic parameters and dimensions 1 Scope This standard specifies the type of household and similar single-phase plugs and sockets, basic parameters and dimensions. This standard applies to the family and home environment similar occasions, the AC frequency of 50Hz, rated voltage of 250V, rated current More than 16A single phase plugs and fixed or portable socket-outlets. 2 Normative references The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 2900.70-2008 Electrotechnical terminology of electrical accessories (IEC 60050 442.? 1998, IDT) GB 2099.1-2008 plug socket for household and similar purposes - Part 1. General requirements (IEC 60884 1.? 2006, MOD) GB/T 1184-1996 shape and position tolerances without individual tolerance value (eqv ISO 2768 2.? 1989) 3 Terms and Definitions GB/T 2900.70-2008 and GB 2099.1-2008 terms and definitions apply to this standard. 4 technical requirements and test methods Technical requirements and test methods for household and similar purposes single-phase plugs and sockets shall comply with the provisions of GB 2099.1-2008. 5 Types, basic parameters and dimensions 5.1 Household and similar single-phase plugs and sockets are divided into two poles and two poles with grounding no grounding two basic types. 5.2 household and similar purposes in the form of a single-phase plug socket, basic parameters and dimensions shall comply with Figs. 1 to 5 and specified in Table 1 to Table 5. 5.3 Inspection of household and similar size single-phase plugs and sockets, use 6 to 18, Tables 6 to 18, those special gauge, indexing value 0.02mm vernier caliper pin end rounded portion size with an appropriate measuring measurement. Insertion force gauge should not exceed GB 2099.1- 2008 specified maximum pull-out force. These gauges all roughness, hardness of 58HRC ~ 62HRC, gauge parallel, vertical Straightness and symmetry and other geometric tolerances according to GB/T 1184-1996 specified tolerance H-level. 5.4 plug shape not specified, but the plug pin distance from the edge of not less than 6.5mm. 5.5 single-phase socket plug sleeve (except the grounding plug cover) from the mating surface of the distance should not be less than a safe distance. These dimensions should test respectively Figure 12, Table 12, Figure 16, Table 16 provided special gauge. 5.6 rated current of 16A single-phase bipolar plug without ground type, parameters and dimensions should be rated current 16A single-phase bipolar with grounding Plug type, parameters and dimensions of the same, but it should be made non-rewirable plug. Ground pin position for the protection of the gate driver chip, the color is black, not Contact wire, marked the ground symbol not only as plug and socket timely open the drive door protection. 1 single-phase polarized plug Table 1 Single-phase basic parameters and dimensions polarized plug The main dimensions of the basic parameters of polarized plug/mm Rated voltage / Rated current / Open files from the connector pin size 6a 12.7 ± 0.14 1.5 0-0.1 6.4 0-0.22 16 ± 0.35 6.0 ± 1 10 12.7 ± 0.14 1.5 0-0.1 6.4 0-0.22 16 ± 0.35 6.0 ± 1 Only a non-rewirable plug for use. It is end thickness suitable chamfering chamfering recommended length of up to 1mm. 2 single-phase pole sockets Table 2 socket single-phase bipolar basic parameters and dimensions The main dimensions of the basic parameters of the poles socket/mm Rated voltage / Rated current / Open files from the socket jack Dimensions FTB 250 10 12.7 ± 0.14 2.0 + 0.140 7.3 + 0.220 3 single-phase bipolar with grounding plug Table 3 single-phase bipolar with grounding plug basic parameters and dimensions The main dimensions of the basic parameters of the poles with grounded plug/mm Rated voltage / Rated current / Open files from the connector pin size 6a 10.3 ± 0.14 7.9 ± 0.11 120 ° ± 30'1.5 0-0.10 6.4 0-0.22 21 ± 0.42 18 ± 0.35 6.0 ± 1 10 10.3 ± 0.14 7.9 ± 0.11 120 ° ± 30'1.5 0-0.10 6.4 0-0.22 21 ± 0.42 18 ± 0.35 6.0 ± 1 16c 11.1 ± 0.14 9.5 ± 0.11 120 ° ± 30'1.8 0-0.10 8.1 0-0.22 21 ± 0.42 18 ± 0.35 6.0 ± 1 Only a non-rewirable plug for use. bC, E end thickness suitable chamfering chamfering recommended length of up to 1mm. c16A2P used only for non-rewirable plug 4 single-phase bipolar with grounding outlet Basic parameters and dimensions of 4 single-phase bipolar with grounding socket The main dimensions of the basic parameters of the poles with ground socket/mm Rated voltage / Rated current / Open files from the socket jack Dimensions AFJTB 10 10.3 ± 0.14 7.9 ± 0.11 120 ° ± 30 '2.0 + 0.140 7.3 + 0.220 16 11.1 ± 0.14 9.5 ± 0.11 120 ° ± 30 '2.4 + 0.140 9.0 + 0.220 5 single-phase two-poles socket Table 5 single-phase two-poles socket basic parameters and dimensions The basic parameters of bipolar dual socket main dimensions/mm Rated voltage / Rated current / Open files from the socket jack Dimensions F1 F2 TBR 250 10 12.7 ± 0.14 19 ± 0.17 2.0 + 0.140 7.3 + 0.220 2.8 + 0.140 Note. R1 is any rounding. 6 Single image with polarized plug gauge Table 6 single-phase polarized plug gauge size The basic parameters of polarized plug gauge dimensions/mm Rated voltage / Rated current / 6 12.7 ± 0.02 1.68 0-0.02 6.45 0-0.05 30 ± 0.20 10 10 12.7 ± 0.02 1.68 0-0.02 6.45 0-0.05 30 ± 0.20 10 Figure 7 gauge grounding plug within a single phase with two poles Table grounding plug gauge dimension within 7 with single-phase bipolar With grounding plug on the basic parameters within the gauge dimensions/mm Rated voltage / Rated current / 6 10.16 0-0.02 7.79 0-0.02 120 ° ± 10 '1.52 0-0.02 6.45 0-0.05 10 10 10.16 0-0.02 7.79 0-0.02 120 ° ± 10 '1.52 0-0.02 6.45 0-0.05 10 16 10.96 0-0.02 9.39 0-0.02 120 ° ± 10 '1.82 0-0.02 8.15 0-0.05 10 , B pg 8 grounding plug external gauge single-phase diagram with two poles Table 8 grounding plug external gauge with single-phase bipolar The basic parameters of the outer poles with grounded plug gauge size/mm Rated voltage / Rated current / 10 10.44 + 0.020 8.0 + 0.020 120 ° ± 10 '1.52 0-0.02 6.45 0-0.05 50 ± 0.3 10 16 11.24 + 0.020 9.61 + 0.020 120 ° ± 10 '1.82 0-0.02 8.15 0-0.05 55 ± 0.3 10 , B pg 9 single-phase pole sockets maximum-gauge Table 9 single-phase pole sockets maximum-gauge size The basic parameters of the maximum pass regulation pole sockets Dimensions/mm Rated voltage / Rated current / Fsg Tsg Bsg Wsg Easg R 250 10 12.84 0-0.02 1.5 0-0.02 6.4 0-0.05 30 ± 0.2 16 0-0.1 6.0 ± 0.5 aEsg chamfer end thickness of 1mm. 10 single-phase pole sockets minimum-gauge Table 10 single-phase pole sockets the size of the minimum-gauge The basic parameters of the minimum-gauge pole sockets Dimensions/mm Rated voltage / Rated current / Fsg Tsg Bsg Wsg Easg R 250 10 12.56 + 0.020 1.5 0-0.02 6.4 0-0.05 30 ± 0.2 16 0-0.1 6.0 ± 0.5 aEsg chamfer end thickness of 1mm. Regulations only 11 single-phase pole sockets Table 11 single-phase pole sockets only regulation size The basic parameters of the bipolar socket only regulation size/mm Rated voltage / Rated current / Fsg Tsg Bsg Wsg Esg 250 10 12.7 ± 0.02 2.15 + 0.020 7.6 + 0.050 30 ± 0.2 10 12 single-phase pole sockets are not in contact regulations Table 12 does not contact the single-phase pole sockets the size of Regulation The basic parameters of the bipolar socket does not contact the gauge size/mm Rated voltage / Rated current / Fsg Tsg Bsg Wsg Esg 250 10 12.7 ± 0.02 1.5 0-0.02 6.4 0-0.05 30 ± 0.2 8.45 0-0.05 13 single-phase bipolar with grounding outlet maximum-gauge Table 13 Single-phase bipolar with grounding outlet through regulation maximum size The basic parameters of the poles with a grounded outlet maximum-gauge size/mm Rated voltage / Rated current / Asg Fsg Jsg Tsg Bsg Wsg Casg Easg R 10 10.44 0-0.02 8.0 0-0.02 120 ° ± 10'1.5 0-0.02 6.4 0-0.05 35 ± 0.2 21 0-0.1 18 0-0.1 6.0 ± 0.5 16 11.24 0-0.02 9.61 0-0.02 120 ° ± 10'1.8 0-0.02 8.1 0-0.05 40 ± 0.2 21 0-0.1 18 0-0.1 6.0 ± 0.5 aCsg, Esg chamfered end thickness of 1mm. 14 single-phase bipolar with grounding outlet minimum-gauge Table 14 Single-phase bipolar with grounding outlet pass minimum size regulation The basic parameters of the poles with a grounded outlet pass regulatory minimum size/mm Rated voltage / Rated current / Asg Fsg Jsg Tsg Bsg Wsg Casg Easg R 10 10.16 + 0.020 7.79 + 0.020 120 ° ± 10'1.5 0-0.02 6.4 0-0.05 35 ± 0.2 21 0-0.1 18 0-0.1 6.0 ± 0.5 16 10.96 + 0.020 9.39 + 0.020 120 ° ± 10'1.8 0-0.02 8.1 0-0.05 40 ± 0.2 21 0-0.1 18 0-0.1 6.0 ± 0.5 aCsg, Esg chamfered end thickness of 1mm. Regulations only 15 single-phase bipolar with grounding outlet Table 15 Single-phase bipolar with grounding receptacle only regulation size The basic parameters of the poles with a grounded outlet only regulation size/mm Rated voltage / Rated current / Asg Fsg Jsg Tsg Bsg Wsg Csg Esg 10 10.3 ± 0.027.9 ± 0.02 120 ° ± 10 '2.15 + 0.020 7.6 + 0.050 35 ± 0.2 10 10 16 11.1 ± 0.029.5 ± 0.02 120 ° ± 10 '2.55 + 0.020 9.3 + 0.050 35 ± 0.2 10 10 16 single-phase poles are not in contact with the ground receptacle Regulation Table 16 Single-phase bipolar with grounding outlet does not contact the gauge size The basic parameters of the poles is not in contact with the ground receptacle regulation size/mm Rated voltage / Rated current / Asg Fsg Jsg Tsg Bsg Wsg Casg Esg R 10 10.3 ± 0.027.9 ± 0.02 120 ° ± 10'1.5 0-0.02 6.4 0-0.0535 ± 0.2 21 0-0.1 10.35 0-0.05 6.0 ± 0.5 16 11.1 ± 0.029.5 ± 0.02 120 ° ± 10'1.8 0-0.02 8.1 0-0.0535 ± 0.2 21 0-0.1 10.35 0-0.05 6.0 ± 0.5 aCsg chamfer end thickness of 1mm. 17 single-phase two-poles socket round plug part through regulation Table 17 dual-socket single-phase bipolar circular interpolation section through regulation size The basic parameters of bipolar double round plug socket part through regulation size/mm Rated voltage / Rated current / F2sg Dsg Wsg Esg SR 250 10 19 ± 0.02 4.8 0-0.05 30 ± 0.2 19.5 0-0.1 6.0 ± 0.5 Figure 18 Single-phase dual-socket bipolar circular interpolation section only regulation Table 18 dual-socket single-phase bipolar circular interpolation section only regulation size The basic parameters of bipolar double round plug socket part only regulation size/mm Rated voltage / Rated current / F2sg Dsg Wsg Esg 250 10 19 ± 0.02 5.9 + 0.020 30 ± 0.2 10 ......

BASIC DATA
Standard ID GB 1002-2024 (GB1002-2024)
Description (Translated English) Single phase plugs and socket-outlets for household and similar purposes - Types, basic parameters and dimensions
Sector / Industry National Standard
Classification of Chinese Standard K30
Classification of International Standard 29.120.30
Word Count Estimation 30,353
Date of Issue 2024-07-24
Date of Implementation 2025-08-01
Older Standard (superseded by this standard) GB/T 1002-2021
Administrative Organization Ministry of Industry and Information Technology of the People Republic of China
Proposing organization Ministry of Industry and Information Technology of the People's Republic of China
Issuing agency(ies) State Administration for Market Regulation, National Standardization Administration

BASIC DATA
Standard ID GB/T 1002-2021 (GB/T1002-2021)
Description (Translated English) Single phase plugs and socket-outlets for household and similar purposes -- Types, basic parameters and dimensions
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K30
Classification of International Standard 29.120.30
Word Count Estimation 15,125
Date of Issue 2021-10-11
Date of Implementation 2022-11-01
Older Standard (superseded by this standard) GB/T 1002-2008
Drafting Organization China National Electrical Equipment Research Institute Co., Ltd., Hangzhou Hongyan Electric Co., Ltd., Zhejiang Chint Construction Electric Co., Ltd., Bull Group Co., Ltd., Zhejiang Delixi International Electric Co., Ltd., Legrand Intelligent Electric (Huizhou) Co., Ltd., Panasonic Electric Machinery (Beijing) Co., Ltd., Weikai Testing Technology Co., Ltd., Feidiao Electric Group Co., Ltd., Qingmi (Beijing) Technology Co., Ltd., Jiangsu Tongling Technology Co., Ltd., Panasonic Information Instrument (Shanghai) Co., Ltd., Haige Electric ( Huizhou) Co., Ltd., Ningbo Boxing King Electric Co., Ltd., Zhongshan Jiadi Electric Co., Ltd., Honeywell Automation Control (China) Co., Ltd., Taili Industrial Co., Ltd., Boshuo Technology (Jiangxi) Co., Ltd., Jiaxing Weikai Testing Technology Co., Ltd., Guangdong Futian Electric Co., Ltd.
Administrative Organization National Electrical Accessories Standardization Technical Committee (SAC/TC 67)
Regulation (derived from) National Standard Announcement No. 12 of 2021
Proposing organization China Electrical Equipment Industry Association
Issuing agency(ies) State Administration for Market Regulation, National Standardization Administration

BASIC DATA
Standard ID GB 1002-2008 (GB1002-2008)
Description (Translated English) [GB/T 1002-2008] Single phase plugs and socket-outlets for household and similar purposes. Types, basic parameters and dimensions [Quasi-Official / Academic version - translated by Chinese Institute]
Sector / Industry National Standard
Classification of Chinese Standard K30
Classification of International Standard 29.120.30
Word Count Estimation 14,167
Date of Issue 2008-09-24
Date of Implementation 2009-08-01
Older Standard (superseded by this standard) GB 1002-1996
Quoted Standard GB/T 2900.70-2008; GB 2099.1-2008; GB/T 1184-1996
Drafting Organization China Electric Apparatus Research Institute
Administrative Organization National Standardization Technical Committee of electrical accessories
Regulation (derived from) Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall)
Proposing organization China Electrical Equipment Industry Association
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This Chinese standard specifies the household and similar purposes the type of single-phase plugs and sockets, basic parameters and dimensions. This standard applies to home and family environment similar occasions, the AC frequency of 50Hz, rated voltage of 250V, rated current not exceeding 16A single phase plugs and fixed or portable socket-outlets.