Home Cart Quotation Policy About-Us
www.ChineseStandard.net
Database: 221581 (27 Mar 2026)
SEARCH
Path: Home > YY/T > Page18 > YY/T 0920-2014

YY/T 0920-2014 PDF English

Price & Delivery

US$210.00 · In stock · Download in 9 seconds
YY/T 0920-2014: Non-active surgical implants. Joint replacement implants. Specific requirements for hip-joint replacement implants
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
YY/T 0920-2014210 Add to Cart Auto, 9 seconds. Non-active surgical implants. Joint replacement implants. Specific requirements for hip-joint replacement implants Valid

Click to Preview this PDF

YY/T 0920-2014: Non-active surgical implants. Joint replacement implants. Specific requirements for hip-joint replacement implants


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YYT0920-2014
YY INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.40 C 35 YY/T 0920-2014 / ISO 21535:2007 Non-active surgical implants - Joint replacement implants - Specific requirements for hip-joint replacement implants (ISO 21535:2007, IDT) ISSUED ON: JUNE 17, 2014 IMPLEMENTED ON: JULY 1, 2015 Issued by: China Food and Drug Administration

Table of Contents

Foreword ... 3 Introduction ... 5 1 Scope ... 6 2 Normative references ... 6 3 Terms and definitions ... 7 4 Expected performance ... 8 5 Design attributes ... 8 6 Materials ... 9 7 Design evaluation ... 10 8 Manufacturing ... 11 9 Sterilization ... 11 10 Packaging ... 11 11 Information provided by the manufacturer ... 11 Appendix A (Informative) Evaluation of relative angular motion of components ... 14 References ... 16

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard is translated and identical to ISO 21535:2007 Non-active surgical implants - Joint replacement implants - Specific requirements for hip-joint replacement implants. The Chinese documents that have consistent correspondence with the international documents normatively cited in this standard are as follows: -- YY/T 0640-2008 Non-active surgical implants - General requirements (ISO 14630:2005, IDT) -- YY/T 0809.1 Implants for surgery - Partial and total hip joint prostheses - Part 1: Classification and designation of dimensions (YY/T 0809.1-2010, ISO 7206- 1:2008, IDT) -- YY/T 0809.2 Implants for surgery - Partial and total hip joint prostheses - Part 2: Articulating surfaces made of metallic, ceramic and plastic materials (YY/T 0809.2-2010, ISO 7206-2:1996, MOD) -- YY/T 0809.4 Implants for surgery - Partial and total hip joint prostheses - Part 4: Determination of endurance properties of stemmed femoral components (YY/T 0809.4-2010, ISO 7206-4:2002, MOD) -- YY/T 0809.6 Implants for surgery - Partial and total hip joint prostheses - Part 6: Determination of endurance properties of head and neck region of stemmed femoral components (YY/T 0809.6-2010, ISO 7206-6:1992, MOD) -- YY/T 0809.10 Implants for surgery - Partial and total hip joint prostheses - Part 10: Determination of resistance to static load of modular femoral heads (YY/T 0809.1-2010, ISO 7206-10:2003, MOD) Please note that some of the contents of this document may involve patents. The issuing agency of this document is not responsible for identifying patents. This standard was proposed by China Food and Drug Administration. This standard shall be under the jurisdiction of the Sub-Technical Committee on Orthopedics Implants of the National Technical Committee on Implants for Surgery and Orthopedic Devices of Standardization Administration of China (SAC/TC110/SC1). Drafting organizations of this standard: Committee for Surgical Implants Chinese Association of Medical Device Industry, Tianjin Medical Devices Quality Supervision Non-active surgical implants - Joint replacement implants - Specific requirements for hip-joint replacement implants

1 Scope

This standard specifies specific requirements for hip joint replacement implants. With regard to safety, this standard specifies requirements for expected performance, design attributes, materials, design evaluation, fabrication, sterilization, packaging, and information provided by the manufacturer, as well as test methods.

2 Normative references

The following documents are essential to the application of this document. For the dated referenced documents, only the versions with the indicated dates are applicable to this document; for the undated referenced documents, only the latest version (including all the amendments) is applicable to this document. YY/T 0640-2008 Non-active surgical implants - General requirements (ISO 14630:2005, IDT) YY/T 0809.1 Implants for surgery - Partial and total hip joint prostheses - Part 1: Classification and designation of dimensions (YY/T 0809.1-2010, ISO 7206- 1:2008, IDT) YY/T 0809.2-2010 Implants for surgery - Partial and total hip joint prostheses - Part 2: Articulating surfaces made of metallic, ceramic and plastic materials (ISO 7206-2:1996, MOD) YY/T 0809.4 Implants for surgery - Partial and total hip joint prostheses - Part 4: Determination of endurance properties of stemmed femoral components (YY/T 0809.4-2010, ISO 7206-4:2002, MOD) YY/T 0809.6-2010 Implants for surgery - Partial and total hip joint prostheses - Part 6: Determination of endurance properties of head and neck region of stemmed femoral components (ISO 7206-6:1992, MOD) YY/T 0809.10 Implants for surgery - Partial and total hip joint prostheses - Part 10: Determination of resistance to static load of modular femoral heads (YY/T 0809.10-2010, ISO 7206-10:2003, MOD) 11.3 Structural and functional compatibility of components 11.3.1 If a femoral component or modular femoral head is only expected to be compatible with the structures and functions of specific acetabular cups, the compatible acetabular cups shall be stated in its label, instruction leaflet, or manual. 11.3.2 If an acetabular component is only expected to be compatible with the structures and functions of specific femoral components, the compatible femoral components shall be stated in its label, instruction leaflet, or manual. 11.3.3 For a femoral component and head of modular construction, the label, instruction leaflet, or manual shall state for each, the corresponding components with which they are structurally and functionally compatible. NOTE: In general, components made by different companies may not match. This applies in particular to modular components with male or female tapered connections. 11.4 Marking 11.4.1 The nominal diameter of the femoral head shall be marked on a monobloc femoral component. 11.4.2 A modular femoral head shall be marked to identify its nominal outer diameter and the characteristics of the cone and bore connection. In normal or corrected vision, these markings shall be legible. 11.4.3 For the stemmed femoral component of the hip joint replacement implant matched with the modular femoral head in the way of a male/female tapered connection, as long as the expected function of the component is not damaged, there shall be a mark indicating the connection method. Markings required for identification or other reasons may be located on the neck of the femoral component of a hip joint replacement implant only if it is proven that endurance property will not be impaired. For stemmed femoral components fitted with modular femoral heads, the marking shall be located on the proximal end face of the conical region where the femoral head is fitted. In normal or corrected vision, the marking shall be clear. 11.4.4 The acetabular component with the articular surface of a total hip joint arthroplasty shall be marked with the nominal diameter of the articular surface. In normal or corrected vision, the marking shall be clear. 11.5 Information provided to patients The manufacturer shall at least make the following statement or equivalent statement in the instruction leaflet or manual: “Patients receiving hip joint replacements should be advised that the longevity of the ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of YY/T 0920-2014 be delivered?Answer: The full copy PDF of English version of YY/T 0920-2014 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of YY/T 0920-2014_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0920-2014_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- YY/T 0920-2014 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of YY/T 0920-2014?

A step-by-step guide to download PDF of YY/T 0920-2014_EnglishStep 1: Visit website ChineseStandard.net (Pay in USD), or ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "YY/T 0920-2014".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 And 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe Or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment Is completed And in 9 seconds, you will receive 2 emails attached with the purchased PDFs And PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs And invoice.
Refund Policy Privacy Policy Terms of Service