GB/T 38034-2019 PDF English
Price & Delivery
US$100.00 · In stock · Download in 9 secondsGB/T 38034-2019: Footwear - Test methods for slide fasteners - Lateral strength
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
| Standard ID | USD | BUY PDF | Delivery | Standard Title (Description) | Status |
| GB/T 38034-2019 | 100 | Add to Cart | Auto, 9 seconds. | Footwear - Test methods for slide fasteners - Lateral strength | Valid |
Click to Preview this PDF
Similar standards
GB/T 38034-2019: Footwear - Test methods for slide fasteners - Lateral strength
---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT38034-2019GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 61.060 Y 78 GB/T 38034-2019 / ISO 10764:2016 Footwear - Test methods for slide fasteners - Lateral strength (ISO 10764:2016, IDT) ISSUED ON: OCTOBER 18, 2019 IMPLEMENTED ON: MAY 01, 2020 Issued by: State Administration for Market Regulation; Standardization Administration of the People's Republic of China.
Table of Contents
Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Terms and definitions ... 4 4 Test equipment and materials ... 6 5 Test sample ... 6 6 Steps ... 7 7 Test report ... 8 Footwear - Test methods for slide fasteners - Lateral strength1 Scope
This Standard specifies the test method for lateral strength of slide fasteners for footwear. This Standard is applicable to various slide fasteners for footwear.2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 7500-1, Metallic materials - Calibration and verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Calibration and verification of the force-measuring system ISO 18454, Footwear - Standard atmospheres for conditioning and testing of footwear and components for footwear ISO 19952, Footwear - Vocabulary3 Terms and definitions
For the purposes of this document, the terms and definitions defined in ISO 19952 as well as the followings apply. 3.1 slide fastener a connecting piece for fixing two pieces of flexible material; it is composed of inter-lockable teeth attached to the opposite edges of two tapes and a movable slider that spans the teeth; when the slider moves in one direction, the teeth (3.5) on the two tapes (3.2) can be meshed with each other NOTE: When the slider (3.3) moves in the opposite direction, the teeth can be separated (see Figure 1). teeth4 Test equipment and materials
4.1 Tensile testing machine. 4.1.1 Clamp: separation speed is (100±10) mm/min. 4.1.2 Device that records the maximum force during the test: the force measurement range is to 2.0kN; the accuracy is greater than 2%; meets the requirements for level two in ISO 7500-1. 4.1.3 Two clamps: - Nip width is (25.5±0.5) mm; - Clamping surface: a flat surface with ripples or covered with rough paper; - Do not apply local pressure on the clamping edge. 4.2 Use a positioning fixture to fix two clamps (4.1.3). Make the clamping edges parallel and center aligned. The minimum size of the metal block is 200mm×30mm×10mm, with a shallow slot with a minimum length of 200mm and a width of less than 26 mm, but large enough to allow the clamps (4.1.3) to move freely. 4.3 For heavy slide fastener, use solvent-based polychloroprene adhesive to help the clamp (4.1.3) to clamp the stringer.5 Test sample
5.1 At least 3 test positions are required. Each test position is at least 50 mm away from the free end of the slide fastener. 5.2 If there are 3 slide fasteners, test the midpoint of each slide fastener. 5.3 If there is only 1 slide fastener, test 3 positions, at least 50 mm from both ends of the slide fastener and the midpoint of the slide fastener. During the test, the free length of the slide fastener at each end of the clamping area is at least 50 mm. Therefore, the total length of the chain is at least 275 mm. Each test can separate a segment of teeth. For the teeth with a total length close to 275 mm, until after each test, the nearby test position can be precisely determined. 5.4 For each test point, mark a line with a length of (25±2) mm on each stringer: ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.