GB/T 32786-2016 PDF English
Price & Delivery
US$110.00 · In stock · Download in 9 secondsGB/T 32786-2016: Pig iron contenting nickel -- Determination of iron content -- Dichromate titration method
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
| Standard ID | USD | BUY PDF | Delivery | Standard Title (Description) | Status |
| GB/T 32786-2016 | 110 | Add to Cart | Auto, 9 seconds. | Pig iron contenting nickel -- Determination of iron content -- Dichromate titration method | Valid |
Click to Preview this PDF
Similar standards
GB/T 32786-2016: Pig iron contenting nickel -- Determination of iron content -- Dichromate titration method
---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT32786-2016
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 77.100 H 11 Pig iron contenting nickel - Determination of iron content - Dichromate titration method ISSUED ON: JUNE 14, 2016 IMPLEMENTED ON: MAY 01, 2017 Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the People’s Republic of China.
Table of Contents
Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Principle ... 4 4 Reagents ... 5 5 Instruments ... 6 6 Sample taking ... 6 7 Analysis steps ... 6 8 Result calculation ... 7 9 Allowable difference ... 8 10 Test report ... 8 Pig iron contenting nickel - Determination of iron content - Dichromate titration method WARNING – The personnel who uses this Standard shall have hands-on experience in formal laboratory work. This Standard does not address all possible security issues. It is the responsibility of the user to take appropriate safety and health measures and to ensure compliance with the conditions which are set by the relevant national regulations.1 Scope
This Standard specifies the potassium dichromate titration method for the determination of iron content. This Standard applies to the determination of iron content in pig iron contenting nickel; the determination range (mass fraction): 65.00% ~ 90.00%.2 Normative references
The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document. GB/T 4010, Ferroalloys sampling and preparation of samples for chemical analysis GB/T 6682, Water for analytical laboratory use - Specification and test methods GB/T 12805, Laboratory glassware - Burettes GB/T 12806, Laboratory glassware - One-mark volumetric flasks GB/T 12808, Laboratory glassware - One mark pipettes3 Principle
After the sample is decomposed by acid, the ammonia water precipitates iron. In hydrochloric acid solution, use stannous chloride and titanium trichloride to reduce iron to divalent. In the presence of the sulfuric acid-phosphoric acid 4.15 Potassium dichromate standard titration solution, c(ଵK2Cr2O7) = 0.04 000 mol/L. Accurately weigh 1.961 2 g of potassium dichromate (reference) that has been dried at 105 °C ± 5 °C for 1 h and cooled to room temperature in a 500 mL beaker; add 100 mL of water. After the potassium dichromate is fully dissolved, transfer it to a 1 000 mL volumetric flask; use water to dilute to the mark; mix well. 4.16 Sodium diphenylamine sulfonate indicator solution, 5g/L.5 Instruments
Ordinary laboratory instruments; burettes, one-mark volumetric flasks, and one mark pipettes shall meet the requirements of GB/T 12805, GB/T 12806 and GB/T 12808, respectively.6 Sample taking
Laboratory samples for analysis shall be taken and prepared in accordance with GB/T 4010. The crushed and ground sample shall pass through the 0.125 mm sieve; the drilled sample shall pass through the 1.68 mm sieve.7 Analysis steps
7.1 Sample mass Weigh 0.10 g of sample (see Chapter 6), to the nearest 0.000 1 g. 7.2 Number of determinations Measure the same sample at least twice independently. 7.3 Blank test Use the same amount of all reagents and follow the same procedure as the sample to determine the blank test value. Before using stannous chloride solution (4.10) for reduction and oxidation titration (7.4.2), use the one mark pipette to pipette 2.00 mL of ammonium ferrous sulfate solution (4.14); titrate the solution according to step 7.4.2. Record the consumed volume (V1). Then, use the one mark pipette to transfer 2.00 mL of ammonium ferrous sulfate solution (4.14); titrate the solution according to step 7.4.2. Record the consumed volume (V2). Thus, obtain the reagent blank V0 for sample analysis (i.e. V1 - V2). ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.