GB/T 6682-2008 PDF EnglishUS$70.00 · In stock · Download in 9 seconds
GB/T 6682-2008: Water for analytical laboratory use -- Specification and test methods Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid GB/T 6682: Historical versions
GB/T 6682-2008: Water for analytical laboratory use -- Specification and test methods---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT6682-2008GB ICS 71.040.30 G 60 NATIONAL STANDARD OF THE PEOPLE'S REPUBLIC OF CHINA Replacing GB/T 6682-1992 Water for Analytical Laboratory Use - Specification and Test Methods Issued on. MAY 15, 2008 Implemented on. NOVEMBER 1, 2008 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of the People's Republic of China. Table of ContentsForeword... 3 1 Scope... 4 2 Normative references... 4 3 Appearance... 4 4 Classification... 5 5 Specification... 5 6 Sampling and Storage... 6 7 Test Methods... 7 8 Test Report... 11 Annex A... 12 Annex B... 13ForewordThis Standard is modified in relation to ISO 3696.1987 "Water for Analytical Laboratory Use - Specification and Test Methods" (English edition). This Standard was modified during the adoption of ISO 3696.1987, in consideration of the national conditions of China. Those technical differences have already been incorporated into the text and marked with perpendicular single line on the margin of relevant clauses. Comparison Between chapter and article numbers of this Standard and ISO 3696.1987 is listed in Annex A. Technical differences and reasons between this Standard and ISO 3696.1987 is listed in Annex B for reference. This Standard replaces "Water for Analytical Laboratory Use - Specification and Test Methods" GB/T 6682 - 1992.Compared with GB/T 6682 - 1992, this Standard has the following main changes. - ADD the test report (Chapter 8 of this edition). Annex C of this Standard is normative; Annex A and Annex B are informative. This Standard is proposed by China Petroleum and Chemical Industry Association. This Standard is under the jurisdiction of Chemical Reagent Subcommittee of National Technical Committee on Chemical of Standardization Administration of China (SAC/TC 63/SC 3). Drafting organization of this Standard. Sinopharm Chemical Reagent Co., Ltd. Main drafters of this Standard. Chen Haoyun, Chen Hong. This Standard was issued in 1686 for the first time and revised in 1992 for the first time. Water for Analytical Laboratory Use - Specification and Test Methods1 ScopeThis Standard specifies the grade, specification, sampling and storage, test methods and test report of water for analytical laboratory use. This Standard is applicable to the water for chemical analysis and inorganic trace analysis tests. Water of different grades may be selected according to the requirements of actual work.2 Normative referencesThe provisions in following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard, however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies. GB/T 601 Chemical reagent - Preparations of standard volumetric solutions GB/T 602 Chemical reagent - Preparations of standard solutions for impurity (GB/T 602-2002, ISO 6353-1.1982, NEQ) GB/T 603 Chemical reagent - Preparations of reagent solutions for use in test methods (GB/T 603-2002, ISO 6353-1.1982, NEQ) GB/T 9721 Chemical reagent - General rules for the molecular absorption spectrophotometry (ultraviolet and visible) GB/T 9724 Chemical reagent - General rule for the determination of pH (GB/T 9724-2007, ISO 6353-1.1982, NEQ) GB/T 9740 Chemical reagent - General method for the determination of dry residue after evaporation (GB/T 9740-2008, ISO 6353-1.1982, NEQ)3 AppearanceWater for analytical laboratory use shall be colorless and clear liquid through visual observation.4 ClassificationRaw water for analytical laboratory use shall be drinking water or water in proper purity. 4.1 Grade 1 water Grade 1 water is used for the analytical test with strict requirements, including the test with requirements for particles, such as water for high performance liquid chromatography analysis. 4.2 Grade 2 water Grade 2 water is used for inorganic trace analysis test, such as water for atomic absorption spectroscopy. 4.3 Grade 3 water Grade 3 water is used for general chemical analysis test.5 SpecificationSpecification of water for analytical laboratory use is detailed in Table 1.6 Sampling and Storage6.1 Container 6.1.1 Water of various grades shall be held in closed and special polyethylene container. Grade 3 water may be held in closed and special glass container. 6.1.2 New container shall be processed before application through soaking for 2d~3d with hydrochloric acid solution (mass fraction 20%), repeatedly washing with to-be-measured water, and filling in to-be-measured water and soaking more than 6h. 6.2 Sampling In the case of testing according to this standard, at least 3L of representative water sample shall be taken. Before sampling, the container shall be washed repeatedly with to-be-measured water; during sampling, the container shall be prevented from being contaminated. The container shall be full of water sample. 6.3 Storage During the storage period of water at various grades, the main contamination sources are soluble constituent of container, carbon dioxide in the air and other impurities. Therefore, grade 1 water shall not be stored, but prepared before application.7 Test MethodsIn the test methods, each test shall be carried out in the clean environment and adequate measures shall be taken to prevent the sample from being contaminated. Water sample shall be measured to the accuracy of 0.1mL; adopted solution represented by "%" is mass fraction. Analytical reagent and water of corresponding grade shall be used in the test. 7.1 pH value 100mL of water sample shall be measured out and determined according to the requirements of GB/T 9724. 7.2 Conductivity 7.2.1 Instrument 7.2.2 Determination procedures 7.2.2.1 Install and trial the instrument according to the instructions of conductivity meter. 7.2.2.2 Grade 1 and grade 2 water measurement. install the conductivity cell at the flow water outlet of water treatment unit, adjust the water rate, expel the gas bubble in the pipe and conductivity cell, and then start measurement. 7.2.2.3 Grade 3 water measurement. TAKE 400mL of water sample to a conical flask, INSERT conductivity cell, and then start measurement. 7.2.3 Precautions Conductivity meter and conductivity cell for measurement shall be calibrated regularly. 7.3 Oxidable substance 7.3.1 Reagent preparation 7.3.1.1 Sulfuric acid solution (20%) It shall be prepared according to the requirements of GB/T 603. 7.4 Absorbance It shall be measured according to the requirements of GB/T 9721. 7.4.1 Instrument conditions Quartz absorption cell. thickness of 1cm and 2cm. 7.4.2 Determination procedures Respectively POUR the water sample into 1cm and 2cm absorption cells, USE the water sample in 1cm absorption cell as reference at 254nm, DETERMINE the absorbance of water sample in 2cm absorption cell. If the sensitivity of instrument is insufficient, the thickness of measurement absorption cell may be added properly. 7.5 Evaporation residue 7.5.1 Instrument 7.5.1.1 Rotary evaporator. equipped with 500mL distillation flask. 7.5.1.2 Thermostatic water-bath. 7.5.1.3 Evaporation dish. the materials may be platinum, quartz and borosilicate glass. 7.5.1.4 Electric oven. temperature may be controlled between 105°C±2°C. 7.5.2 Determination procedures 7.5.2.1 Water sample pre-contraction MEASURE out 1000mL of grade 2 water (500mL of grade 3 water), ADD the water sample into the distillation flask of rotary evaporator in several times, CARRY out reduced pressure evaporation on the water bath (avoiding evaporate to dryness), STOP heating until the water sample is evaporated to 50mL. 7.6 Soluble silicon 7.6.1 Reagent preparation 7.6.1.1 Silicon dioxide standard solution (1mg/mL) It shall be prepared according to the requirements of GB/T 602. 7.6.1.2 Silicon dioxide standard solution (0.01mg/mL) MEASURE out 1.00mL of silicon dioxide standard solution (1mg/mL) into a 100mL volumetric flask, DILUTE to the scale, SHAKE up, TRANSFER to a polyethylene bottle, and prepare when needing. 7.6.1.5 Sulfuric acid solution (20%) It shall be prepared according to the requirements of GB/T 603. 7.6.1.6 Oxalic acid solution (50g/L) WEIGH out 5.0g of oxalic acid, DISSOLVE it in water, DILUTE to 100mL, STORE in a polyethylene bottle. 7.6.2 Instruments 7.6.3 Determination procedures MEASURE out 520mL of grade 1 water (270mL of grade 2 water), POUR into a platinum dish, CARRY out sub-boiling evaporation to about 20mL under the dust-proof conditions, STOP heating, COOL down to the room temperature, ADD 1.0mL of ammonium molybdate solution (50g/L), SHAKE up, PLACE for 5 minutes, ADD 1.8 Test ReportTest report shall include the following contents. a) Sample determination; b) Referenced adopted method; c) Results and representation methods; d) Abnormal phenomena description in the determination; e) Any operation not included in this Standard. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 6682-2008 be delivered?Answer: The full copy PDF of English version of GB/T 6682-2008 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 6682-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 6682-2008_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 6682-2008 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version GB/T 6682-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 6682-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of GB/T 6682-2008?A step-by-step guide to download PDF of GB/T 6682-2008_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 6682-2008". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |