GB/T 35801-2018 PDF EnglishUS$150.00 · In stock · Download in 9 seconds
GB/T 35801-2018: Determination of prohibited captan in cosmetics - High performance liquid chromatography Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid
Similar standardsGB/T 35801-2018: Determination of prohibited captan in cosmetics - High performance liquid chromatography---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT35801-2018 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 71.100.70 Y 42 Determination of prohibited captan in cosmetics - High performance liquid chromatography Issued on: FEBRUARY 06, 2018 Implemented on: SEPTEMBER 01, 2018 Issued by. General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the People's Republic of China. Table of ContentsForeword ... 3 Introduction ... 4 1 Scope ... 5 2 Normative references ... 5 3 Principle ... 5 4 Reagents and materials ... 5 5 Apparatus and equipment ... 6 6 Analysis steps ... 6 7 Result calculation ... 8 8 Detection limit and limit of quantification ... 8 9 Recovery rate and precision ... 8 10 Tolerance ... 8 Annex A (informative) Structural formula, high performance liquid chromatogram and ultraviolet absorption spectrum of the captan standard product ... 9 Annex B (informative) Test of confirmation ... 11 Determination of prohibited captan in cosmetics - High performance liquid chromatography1 ScopeThis Standard specifies determination method of high performance liquid chromatography for prohibited captan in cosmetics. This Standard is applicable to determination of captan in creams, liquids, loose powder cosmetics. The detection limit of this Standard for captan is 2 mg/kg, and the limit of quantification is 5 mg/kg.2 Normative referencesThe following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682, Water for analytical laboratory use - Specification and test methods3 PrincipleAfter the specimen is ultrasonically extracted by solvent and is centrifuged, use high performance liquid chromatography to determine, use external standard method to quantify, use liquid chromatography-mass spectrometry to confirm.4 Reagents and materialsUnless otherwise stated, the reagents used are analytically pure, the water is of grade one specified in GB/T 6682. 4.1 Acetonitrile. chromatographically pure. 4.2 Methanol. chromatographically pure. 4.3 Tetrahydrofuran. 6.1.2 Liquid and loose powder samples Weigh 1g (to the nearest of 0.001g) of sample. Place in a 10mL plugged plastic centrifuge tube (5.6). Shake well. Add into 10mL of methanol (4.2). After performing ultrasonic extraction for 20min, centrifugation at 5000r/min for 15min, the supernatant is filtered through a 0.45μm microporous membrane for determination of high performance liquid chromatography. 6.2 Determination conditions The reference conditions for high performance liquid chromatography are as follows. a) Chromatographic column. C18, 5μm, 250mm × 4.6mm (inner diameter), or the equivalent; b) Flow rate. 1.0mL/min; c) Mobile phase. acetonitrile + water = 65 + 35 (volume ratio); d) Detection wavelength. 206nm; e) Column temperature. 30°C; f) Injection volume. 10μL. 6.3 Drawing of standard curve The captan standard working solution (4.7) was determined according to the determination conditions in 6.2 and the concentration from low to high injection. Draw in peak area-concentration. Make standard working curve. See Figure A.2 in Annex A for a high performance liquid chromatogram of the captan standard solution. The UV absorption spectrum of the captan standard product is shown in Figure A.3 of Annex A. 6.4 Determination Conduct determination for the testing sample according to the determination conditions in 6.2. If the retention time of the chromatographic peak detected is consistent with the standard product, and the chromatogram of the sample after subtracting the background, the UV absorption spectrum of the substance is consistent with the standard product, it can be preliminarily determined that captan exists in the sample. Use external standard method to quantify. The content of captan shall be within the standard curve. If it is outside the linear range, it shall be diluted before analysis. If necessary, positive sample shall be confirmed by liquid chromatography-mass spectrometry. See Annex B for confirmation test.Annex B(informative) Test of confirmation B.1 Liquid chromatography conditions The reference conditions for liquid chromatography determination are as follows. a) Chromatographic column. XBridge C18, 3.5μm, 150mm × 2.1mm (inner diameter); b) Mobile phase. 0.1% formic acid solution + acetonitrile = 10 + 90 (volume ratio); c) Flow rate. 0.3mL/min; d) Column temperature. 30°C; e) Injection volume. 5μL. B.2 Mass spectrometry conditions The reference conditions for mass spectrometry are as follows. a) Ion source. electrospray ion source; b) Ionization mode. positive ion mode; c) Capillary voltage. 3.5kV; d) Extraction voltage. 3.0V; e) Ion source temperature. 150°C; f) Desolvation gas temperature. 500°C; g) Data collection method. multiple reaction monitoring. B.3 Qualitative determination When the specimen is measured, the sample solution is appropriately diluted, and the sample solution and the standard working solution are determined according to liquid chromatography-mass spectrometry conditions. If the selected ions are present, and the selected ion ratio is consistent with the ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 35801-2018 be delivered?Answer: The full copy PDF of English version of GB/T 35801-2018 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 35801-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 35801-2018_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 35801-2018 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of GB/T 35801-2018?A step-by-step guide to download PDF of GB/T 35801-2018_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 35801-2018". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |