GB 51039-2014: Code for design of general hospital

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB51039-2014
GB UDC NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA P GB 51039-2014 Code for Design of General Hospital Issued on. DECEMBER 02, 2014 Implemented on. AUGUST 01, 2015 Jointly issued by. Ministry of Housing and Urban-Rural Development (MOHURD); General Administration of Quality Supervision, Inspection and Quarantine (AQSIQ) of the People's Republic of China. NATIONAL STANDARD OF THE PEOPLE'S REPUBLIC OF CHINA Code for Design of General Hospital Developed by. National Health and Family Planning Commission of the People's Republic of China Approved by. Ministry of Housing and Urban-Rural Development of the People's Republic of China Implementation Date. August 1, 2015 China Planning Press 2014 Beijing

Table of Contents

Foreword... 6 1 General Provisions... 8 2 Terms... 8 3 Medical Process... 8 4 Location and General Site... 10 5 Architectural Design... 12 6 Water Supply and Drainage, Fire Prevention and Sewage... 29 7 Heating, Ventilation and Air Conditioning System... 35 8 Electrical... 44 9 Intelligent Systems... 50 10 Medical Gas Systems... 53 11 Steam Systems... 56 Explanation of Wording in This Code... 57 List of Quoted Standards... 58 1 General Provisions 1.0.1 This code is formulated with a view to making the design of general hospital meet the standard and the functional need of medical service and being in conformity with the standards of being safe, hygienic, economical, applicable, energy saving and environmental-friendly. 1.0.2 This code is applicable to design of newly constructed, renovated and extended general hospitals. 1.0.3 Medical process shall be dependent on the construction scale, management model and departments arrangement in the hospital. The design of hospital shall meet the medical process requirements. 1.0.4 Design of general hospital shall not only meet the requirements in this code but also those specified in the current related standards of the Nation. 2 Terms 2.0.1 General hospital Hospitals which are provided with sick beds, departments of internal medicine, surgery, obstetrics and gynecology, pediatrics, ophthalmology, ENT, etc., medical-tech departments of pharmacy, testing, radiation, etc. and corresponding personal and equipment. 2.0.2 Medical process Provision of medical flows and medical equipment as well as other relevant resources. 2.0.3 Medical flows Procedure and link of medical service. 2.0.4 Emergency throughput Capacity of emergency department to accept emergency patient at a time. 2.0.5 Hospital hygiene It is to maintain key departments of hospital to be hygienic and prevent infection and hazards from harmful gas and chemical substances. 3 Medical Process 3.1 General Requirements 3.1.1 Medical process shall determine the medical business structure, function and scale, relevant medical flows, medical equipment, technical conditions and parameters. 3.2 Medical Process Design Parameters 3.2.1 Medical process design parameters shall be dependent on the requirements of hospitals or meet the following requirements if no data are available. 3.2.2 The clinical amount of departments shall be dependent on the statistic data of hospital or Table 3.2.2 when there is no statistical data. 4 Location and General Site 4.1 Location 4.1.1 Location of general hospital shall correspond with local urban planning, regional hygiene planning and environment evaluation. 4.2 General Site 4.2.1 General site design shall meet the following requirements. 4.2.2 The hospital shall be set with at least two entrances, and the personal entrance shall not be used for moving out corpse and waste. 5 Architectural Design 5.1 General Requirements 5.1.1 The plane layout, structural style and electromechanical design of the main building shall create conditions for the development, renovation and flexible separation in future. 5.1.2 Arrangement of building entrance shall meet the following requirements. 5.1.4 Arrangement of elevator shall meet the following requirements. 5.1.7 Over a half ward shall reach the sunlight requirements in GB 50352 Code for Design of Civil Buildings. 5.1.8 The outpatient department, emergency department and wards shall make the best of the natural ventilation and natural illumination. 5.1.13 Arrangement of rest room shall meet the following requirements. 5.2 Outpatient Department 5.2.1 The outpatient department shall be arranged close to the hospital traffic entrance and adjacent to medical technology building; the interrelationship of all divisions within the outpatient department shall be well handled, and the flow line shall be reasonable to avoid hospital infection. 5.2.5 The arrangement of rooms for gynecology, obstetrics and family planning shall meet the following requirements. 5.2.7 The arrangement of rooms for ear-nose-throat department shall meet the following requirements. 5.2.9 The arrangement of rooms for department of stomatology shall meet the following requirements. 5.3 Emergency Department 5.3.1 The arrangement of emergency department shall meet the following requirements. 5.3.3 In case the hall is also used as triage room, its area shall not be less than 24.00m2. 5.4 Infectious Diseases Clinic 5.4.1 The digestive, respiratory and infectious diseases clinic shall be arranged in a separate zone and shall be arranged with separate entrance. 5.4.2 The infectious disease clinic shall be provided with functional rooms for triage, reception, registration, cashier, pharmacy, inspection, examination, isolation observation, therapy, clothes-changing of medical care personnel, buffering and special toilet etc. in accordance With specific conditions. 5.5 Inpatient Department 6 Water Supply and Drainage, Fire Prevention and Sewage 6.1 General Requirements 6.2 Water Supply 6.2.1 The water quality of domestic water in hospital shall meet the relevant requirements of current national standard of GB 5749 Standards for Drinking Water Quality. 6.2.3 Boiler water and make-up water of refrigeration compressor cooling water circulation system shall be determined in accordance with process. 6.2.4 Water supply in burn ward and central sterile supply room shall be arranged with water supply points in accordance with the process requirements of hospital. 6.3 Drainage 6.3.1 Sanitary sewage in hospital dormitory area shall be discharged into municipal sewage drainage pipeline directly; ordinary domestic sewage and wastewater in courtyard area, if conditions permitting, may be discharged into municipal sewage drainage pipeline directly. 6.3.4 The pipe diameter of drainage pipeline of central sterile supply room, traditional Chinese medicine processing room and stomatological department shall be larger than Grade 1~2 of calculated pipe diameter and shall not be less than 100.00mm, pipe diameter of branch pipe shall not be less than 75.00mm. 6.4 Hot Water 6.8 Sewage Treatment 6.8.1 Medical sewage discharge shall meet the relevant requirements of the current national standard of GB 18466 Discharge Standard of Water Pollutants for Medical Organization, and shall meet the following requirements. 6.8.2 The discharge of radioactive sewage shall meet the relevant requirements of the current national standard GB 18871 Basic Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources. 6.9 Pipe Material 6.9.1 Pipe material of water supply and hot water system shall be determined as required, stainless steel pipe, plastic pipe, plastic and metal composite pipe and hot-dip galvanizing steel pipe complying with current relevant national standard may be selected. 7 Heating, Ventilation and Air Conditioning System 7.1 General Requirements 7.1.1 The hospital shall determine to complete heating and ventilation, common air conditioning or cleaning air conditioning in the whole or part of the hospital according to the local climate conditions, hospital nature and the functional requirements of departments and divisions. 7.1.5 When natural ventilation is adopted, the atrium shall be free from obstruction; otherwise, supporting mechanical exhaust shall be used. In the area with applicable climate conditions, through-draught may be utilized and the clean zone shall locate at the windward side of ventilation. 7.1.6 Mechanical exhaust shall be arranged in the room where odor and water vapor are produced and moisture operation is conducted. 7.1.10 The air output in the medical room using central air conditioning system should not be less than 6 times/h. 7.1.11 Filtering equipment (the initial resistance is less than 50Pa, the single pass rate of microorganism is not greater than 10% and the single weight passing rate of particles is not greater than 5%) must be set at the return air inlet of central air conditioning system and fan coil unit. 7.1.15 The exhaust fan without special requirements shall be set at the end of exhaust pipeline to make the whole pipeline under negative pressure. 7.1.16 The hospital heating, ventilation and air conditioning (including cold/heat sources) shall be designed according to the relevant requirements of current national standard "Design Standard for Energy Efficiency of Public Buildings" (GB 50189) under the premise of guaranteeing diagnosis, treatment and infection control. 7.2 General Requirements for Clean Rooms 7.2.1 Clean room shall be selected according to needs and possibilities. 7.5 Inpatient Department 7.5.1 The common inpatient area shall meet the following requirements. 7.5.2 The obstetrics shall meet the following requirements. 7.5.3 The intensive care unit shall meet the following requirements. 7.7 Medical Technology Department 7.7.1 Examination department, pathology department and laboratory shall meet the following requirements. 7.7.2 In vitro fertilization (IVF) laboratory in reproductive science center shall be designed according to Grade I clean room and shall adopt local centralized air supply or clean bench. Egg retrieval room shall be designed according to Grade II clean room and shall adopt local centralized air supply or clean bench. The noise in IVF laboratory and egg retrieval room shall not be greater than 45dB(A). Other clean auxiliary rooms such as freezing room, working room and clean corridor may be designed according to Grade IV clean room and shall adopt local centralized air supply. 8 Electrical 8.1 General Requirements 8.3 Security 8.3.1 If Categories 1 and 2 medical locations use SELV equipment and PELV equipment, the rated voltage of equipment shall not exceed AC root mean square value 25V or ripple-free DC 60V, and insulation protection measures shall be taken. 8.4 Selection and Installation of Electrical Equipment 8.4.1 The isolation transformer of medical IT system shall meet the following requirements. 8.4.2 In Categories 1 and 2 medical locations, Type A or Type B residual current protector shall be selected according to the characteristics of the possible fault current. 8.4.3 Short circuit and overload protection shall be set for each end loop of Category 2 medical locations, but overload protection shall not be set at the primary and secondary sides of transformer for medical IT system. 9 Intelligent Systems 9.1 General Requirements 9.1.1 The hospital shall design the overall framework of intelligent system according to the demands and shall meet the hospital's overall planning requirements. 9.2 Information Facility Systems 9.2.1 The communication access system should be centralized-arranged in the hospital. 9.2.2 Where independent integrated service digital program-controlled user switch system is adopted, the quantity of junction lines shall be determined according to 1/10 of the actual telephone traffic, and allowance shall be reserved. 9.2.6 Where satellite communication system is set, the information communication requirements including voice, data, image, multimedia and the like shall be met. 9.3 Information Application Systems 9.3.1 The hospital information system should be composed of management information system, clinical information system and information support & maintenance system. 9.4 Public Safety Systems 9.4.1 Public safety system shall be provided with automatic fire alarm and firefighting coordinated control system, and the design of automatic fire alarm system shall meet the relevant requirements of the current national standard "Code for Design of Automatic Fire Alarm System" (GB 50116). 9.5 Intelligent Integrated Systems 9.5.1 The intelligent integrated system, if installed, should share information with the information system. If not, building equipment management system should be adopted to integrate the building equipment monitoring and control system and public safety system, and the interface with information system should be reserved. 9.5.2 The hardware and software of the integrated system shall adopt open architecture which shall be practical, safe and reliable, easy to expand and maintain. 9.6 Mechanical Room Works 9.6.1 The machine room shall be designed according to the hospital management mode. ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of GB 51039-2014 be delivered?Answer: The full copy PDF of English version of GB 51039-2014 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB 51039-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB 51039-2014_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB 51039-2014 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of GB 51039-2014?

A step-by-step guide to download PDF of GB 51039-2014_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB 51039-2014".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9