Code for design of gas fire extinguishing systems
|
Basic data | Standard ID | GB 50370-2005 (GB50370-2005) | | Description (Translated English) | Code for design of gas fire extinguishing systems | | Sector / Industry | National Standard | | Classification of Chinese Standard | P16 | | Classification of International Standard | 13.220.10 | | Word Count Estimation | 46,491 | | Date of Issue | 2006-03-02 | | Date of Implementation | 2006-05-01 | | Regulation (derived from) | Bulletin No. 412 of the Ministry of Construction | | Summary | This Chinese standard applies to new construction, renovation, expansion of industrial and civil construction set Heptafluoropropane, IG541 mixed gas and thermal aerosol total flooding fire extinguishing system design. |
GB 50370-2005: Code for design of gas fire extinguishing systems ---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB50370-2005
NATIONAL STANDARD
OF THE PEOPLE'S REPUBLIC OF CHINA
Code for Design of Gas Fire Extinguishing
Systems
Date of issuing. March 2, 2006 Date of enforcement. May 1, 2006
Jointly issued by. Ministry of Construction of the People's Republic of China
General Administration of Quality Supervision, Inspection and
Quarantine of the People's Republic of China
Preface
According to the requirement of "Notice on Promulgation of '"Plan for Preparation and
Modification of National Standards for Project Construction 2001 ~2002" Document JB [2002]
No.26 the \;linistry of Construction of PRC. this Standard is prepared by Tianjin Fire Research
Institute of .V1inistry of Public Security, jointly by other relevant units.
During the preparation. the editorial group carried out thorough and in-depth investigation
and research. carefully summarized achievements of scientific research in the researching.
production. design and application and the practical experience of the engineering about the gas
fire extinguishing systems in our country, referred to the relevant international standards and the
ones of developed countries such as America. Japan and Germany, and employed the fundamental
experiments and the experimental research on engineering applications. After extensive opinions
have been obtained from departments and units of design, scientific research. manufacturing,
construction, universities and colleges, and supervision on fire fighting, the Standard is finalized
by relevant depaiiments, under the review of expe1is.
This Standard consists of 6 chapters and 7 appendixes, in which the main contents are.
general, terms and symbols, design requirements, system components. operation and controL and
safety requirements.
Those clauses in block are mandatory clauses, which must be forced strictly.
The Ministry of Construction will be responsible for the management and explanation on the
mandatory clauses. The Ministry of Public Security will be responsible for the specific
management. Tianjin Fire Research Institute of Ministry of Public Security will be responsible for
the explanation on the detailed technical contents. During the implementation. the users of this
Standard are kindly required to summarize experience and collect materials, and send any
suggestion or comment in this regard to Tianjin Fire Research Institute of Ministry of Public
Security (Address. 110 South Road of Weijin of Nankai District Tianjin. Post Code. 300381) at
any time for reference in future revision.
Chief editorial units. paiiicipating editorial units and major drafters of this Standard.
Chief editorial units. Tianjin Fire Research Institute of Ministry of Public Security
Participating editorial units. National Quality Supervision & Testing Center on Fixed Fire
Extinguishing Systems and Fire-Retarding Components
Beijing Urban Engineering Design & Research Institute
China Academy of Railway Sciences
Shenzhen International Safety Technology Co., Ltd.
China Mobile Communications Corporation
Shanxi General Fire Brigade of Public Security
Fire Administration of Shenzhen Public Security Bureau
Guangdong Shengjie Fire Protection Group
Zhejiang Lantian Environmental Protection Hi-Tech Co., Ltd.
Hangzhou New Epoch Fire Protection Science and
Technology Co., Ltd.
Xi'an Jianrui Chemical Industry Co., Ltd.
Table of Contents
General ... J
7 Terms and Symbols ... 2
2.1 Terms ... 2
2.2 Symbols ... 3
3 De.s ign Require1r·1e.nts ... 6
3. ! Ge neral Provis ions ... 6
3.2 System Set-up ... 7
3.3 Extinguishing Systen1s of Hepta-Fluoropropane ... 8
3.4 IG541 Mixed Gas Fire-Extinguishing System ... 13
3.5 Pre-engineered Syste m of Condensed Fire-Extinguishing Aerosol... 16
System Components ... 18
4. 1 General Provi sions ... 18
4.2 Special Requirements on Components of Hepta-Fluoropropane Extinguishing Systems
... 19
4.3 Special Requirements on Components of IG54 l Mixed-Gas Extinguishing Systems .. 20
4.4 Special Requirements on Components of Pre-Engineered Systems of Condensed
Fire-Extinguishing Aerosol... 20
5 Operations and Contro ls ... 21
6 Safety Requirements ... 22
Appendix A Concentrations of Extinguishing and Inerting ... 23
Appendix B Modified Coefficients of Height above Sea level ... 25
Appendix C Jetting Rate of Equivalent Orifice Unit Area about Nozzles of Hepta-Fluoropropane
Extinguishing System ... 26
Appendix D Nozzle Specifications and Equivalent Orifice Area ... 28
Appendix E Coefficients of Both Pressure and Density on Pipe Channels of IG54 l Mixed Gas
Extinguishing Systems ... 29
Appendix F Jetting Rate of Equivalent Orifice Unit Area about Nozzles of IG541 Mixed Gas
Extinguishing System ... 3 1
Appendix G Concentrations of No-Toxicity Response (NOAEL) and with Toxicity Response
(LOAEL) and Technological Properties of Fire Agent... 33
Word Diction of the Code ... 34
1 General
1.0.1 This Standard has been \\ orked out for the purpose of designing gas fire extinguishing
systems reasonably, reducing fire damage. and protecting the safety of human body and properties.
1.0.2 This code applies to the design on total flooding extinguishing of
hepta-tluorupropane, mixed gas 1G54 l. and condensed fire extinguishing aerosol.
1.0.3 Design of gas fire extinguishing systems shall comply with the national guiding
principles and policies, and be safe, technologically advanced. economic and reasonable .
1.0.4 Products and components of the system applied according to the design must be m
accordance with national standards and regulations.
1.0.5 Besides complying \\ith this standard, the design of gas fire extinguishing systems shall
also comply with other relevant current national standards.
2 Terms and Symbols
2. 1 Terms
2.1. l Protected area
The restricted enclosure space sati sfying the demands of total f1ood extinguish ing system
2.1.2 Tota! flooding extinguish ing system
The fire extinguishing system in \\'h ich dur ing the regulated time the fire agent with the
designed standard use level is ble\\ towa1·cls the protected area w hi ch is filled with the agent
evenly.
2.1.3 Piping extinguishing system
The fire extinguishing system in which the fire agent transported from storage device to
blowing components via main and branch pipes is blew based on the design and calculation
according to cetta in appl ication conditions.
2.1.4 Pre-engineered system
The fire extinguishing system in which the storage device and blowing components of fire
agent are pre-designed and assembled to be a whole set with functions of gang control
2.1.5 Combined distribution systems
The fire extinguishing system in which a set of storage devices of gas extinguishing agent is
applied through the selection distribution of pipe network to protect two or more than two
protected areas.
2.1.6 Flame extinguishing concentration
The mi nimum volume percent of the gas extinguishing agent in the air needed fo r putting out
ce1tain fire under circumstances of l 0 1 kPa air pressure and regulated temperature.
2.1. 7 Flame extinguishing density
The mass of solid condensed-fire -extinguishing-aerosol generate needed for putting out
certain fire in the unit volume, under circumstances of 101 kPa air pressure and regu lated
temperature.
2.1.8 Inerting concentration
The minimum volume percent of the gas extinguishing agent in the air needed fo r restraining
the occurrence of burning rising from the f1ammable and combustible gas or liquid steam with any
concentration in the air, under circumstances of l 01 kPa air pressure and regulated temperature, in
case of the fire source.
2.1.9 Soaking time
The time that the designed concentration of fire agent is maintained in the protected areas to
put out the fire completely
2.1.10 Pressure re lief opening
The opening where the pressure is released to prevent the internal pressure of protected areas
fro m ex~eeding the allowable pressure, in case of the blowing of fire agent.
2...
...
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 50370-2005_English be delivered?Answer: Upon your order, we will start to translate GB 50370-2005_English as soon as possible, and keep you informed of the progress. The lead time is typically in 9 seconds (download/delivered in 9 seconds). The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 50370-2005_English with my colleagues?Answer: Yes. The purchased PDF of GB 50370-2005_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|