GB 43630-2023 PDF English
US$275.00 · In stock · Download in 9 seconds
GB 43630-2023: Minimum allowable values of energy efficiency and energy efficiency grades for tower and rack servers
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
GB 43630-2023: Minimum allowable values of energy efficiency and energy efficiency grades for tower and rack servers
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
| Standard ID | USD | BUY PDF | Delivery | Standard Title (Description) | Status |
| GB 43630-2023 | 275 | Add to Cart | Auto, 9 seconds. | Minimum allowable values of energy efficiency and energy efficiency grades for tower and rack servers | Valid |
Similar standards
GB 43630-2023: Minimum allowable values of energy efficiency and energy efficiency grades for tower and rack servers
---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB43630-2023
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 27.010 CCS F 01 Minimum allowable values of energy efficiency and energy efficiency grades for tower and rack servers Issued on: DECEMBER 28, 2023 Implemented on: JANUARY 01, 2025 Issued by. State Administration for Market Regulation; Standardization Administration of the People's Republic of China.
Table of Contents
Foreword... 3 1 Scope... 4 2 Normative references... 4 3 Terms and definitions... 4 4 Technical requirements... 5 5 Test methods... 6 Annex A (normative) Requirements for server energy efficiency testing... 7 Annex B (normative) Server energy efficiency calculation method in the benchmark tool for server energy efficiency (BenchSEE)... 10 Bibliography... 15 Minimum allowable values of energy efficiency and energy efficiency grades for tower and rack servers1 Scope
This document specifies the energy efficiency grades and energy efficiency limits for tower and rack servers. It also describes the corresponding test methods. This document applies to one-way or two-way general-purpose tower and rack servers (hereinafter referred to as. servers). This document does not apply to servers that only have auxiliary processing accelerators. NOTE. One-way or two-way refers to the number of central processing unit (CPU) slots in a server, which is 1 or 2.2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 9813.3, General specification for computer -- Part 3.Server ISO/IEC 21836.2020, Information technology -- Data centres -- Server energy effectiveness metric3 Terms and definitions
For the purposes of this document, the terms and definitions defined in GB/T 9813.3, ISO/IEC 21836.2020 as well as the followings apply. 3.1 work mode A mode of which the server operating system and other software are fully loaded, and the server runs a load test. 3.2 energy efficiency of servers Under specified test conditions, the ratio of server performance standard score to energy consumption. NOTE. The energy efficiency of servers is obtained by running the benchmark tool for server energy efficiency (BenchSEE). 3.3 minimum allowable values of energy efficiency for servers The minimum energy efficiency or energy efficiency score allowed by the server under specified test conditions. NOTE. The energy efficiency score is obtained by running the testing tool for the energy efficiency of servers specified in ISO/IEC 21836.2020.4 Technical requirements
4.1 Efficiency grades The energy efficiency of servers is classified into three levels, with Level 1 being the most efficient. For servers equipped with CPUs manufactured using a process technology of 14 nm or larger, or CPUs manufactured using non-extreme ultraviolet (EUV) lithography equipment, the energy efficiency of each level conforms to the specifications in Table 1.For servers equipped with CPUs manufactured using a process technology smaller than 14 nm, the energy efficiency of each level conforms to the specifications in Table 2. 4.2 Energy efficiency limits 4.2.1 For servers configured with central processing units (CPUs) manufactured using a process of 14 nm or greater, or with CPUs manufactured using non-EUV lithography equipment, the energy efficiency limits shall comply with Level 3 in Table 1. 4.2.2 For servers configured with central processing units manufactured using a process smaller than 14 nm, the energy efficiency limits shall comply with Level 3 in Table 2. 4.2.3 The energy efficiency of servers may be determined using the benchmark tool for server energy efficiency (BenchSEE) only when the energy efficiency of servers cannot be measured. The server energy efficiency score may be obtained using the server energy efficiency testing tool specified in ISO/IEC 21836.2020.The server energy efficiency score shall comply with the requirements in Table 3.5 Test methods
5.1 Server energy efficiency testing shall be conducted in accordance with the requirements of Annex A. 5.2 The energy efficiency of servers is calculated in the benchmark tool for server energy efficiency (BenchSEE) according to the method in Annex B.Annex A
(normative) Requirements for server energy efficiency testing A.1 Test environment requirements The test environment meets the following requirements. a) The ambient temperature shall be 25℃ ±5℃. The atmospheric pressure shall be 86 kPa~106 kPa. b) For servers under test with a nominal power of 1.5 kW or less, the test power supply shall be AC (220±1%)V. For servers under test with a nominal power greater than 1.5 kW, the test power supply shall be AC (220±4%)V. c) For servers under test with a nominal power of 1.5 kW or less, the current harmonic distortion of the test power supply shall not exceed 2%. For servers under test with a nominal power greater than 1.5 kW, the current harmonic distortion of the test power supply shall not exceed 5%. d) The power input frequency shall be (50±1.0%)Hz. A.2 Test instrument and equipment requirements The test instruments and equipment must meet the following requirements. a) The power meter and temperature sensor shall be annually calibrated according to relevant requirements. b) The power meter shall provide power measurements. The overall relative error of all power measurements shall not exceed 1%. The minimum frequency response is 3.0 kHz. c) The temperature sensor accuracy error shall be ±0.5℃ or less. d) The power meter shall be directly connected between the AC power supply and the server under test. Uninterruptible power supplies (UPS) shall not be used. e) The data output interfaces of the power meter and temperature sensor shall be connected to the corresponding input interfaces of the test host computer. Power and temperature data shall be automatically recorded by the test host computer. Manual recording is not allowed. f) The benchmark tool for server energy efficiency (BenchSEE) used for testing shall ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked Questions:
Question 1: How long will the true-PDF of English version of GB 43630-2023 be delivered?
Answer: The full copy PDF of English version of GB 43630-2023 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB 43630-2023_English with my colleagues?
Answer: Yes. The purchased PDF of GB 43630-2023_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?
Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?
Answer: Yes. www.ChineseStandard.us -- GB 43630-2023 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of GB 43630-2023?
A step-by-step guide to download PDF of GB 43630-2023_English
Step 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB 43630-2023".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9