Home Cart Quotation Policy About-Us
www.ChineseStandard.net
Database: 221581 (27 Mar 2026)
SEARCH
Path: Home > YY/T > Page29 > YY/T 1996-2025

YY/T 1996-2025 PDF English

Price & Delivery

US$279.00 · In stock · Download in 9 seconds
YY/T 1996-2025: Brain-computer interface medical device - Closed-loop implantable neurostimulator - Test method for sensing and response performance
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Std IDVersionUSDBuyDeliver [PDF] inTitle (Description)
YY/T 1996-2025English279 Add to Cart 3 days [Need to translate] Brain-computer interface medical device - Closed-loop implantable neurostimulator - Test method for sensing and response performance

Click to Preview a similar PDF

Basic data

Standard ID YY/T 1996-2025 (YY/T1996-2025)
Description (Translated English) Brain-computer interface medical device - Closed-loop implantable neurostimulator - Test method for sensing and response performance
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C31
Classification of International Standard 11.40.040
Word Count Estimation 14,171
Date of Issue 2025-09-25
Date of Implementation 2027-10-01
Issuing agency(ies) National Medical Products Administration

YY/T 1996-2025: Brain-computer interface medical device - Closed-loop implantable neurostimulator - Test method for sensing and response performance





---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 11.40.040CCS C 31 Pharmaceutical Industry Standards of the People's Republic of China Released on 2025-09-25 Implemented on October 1, 2027 Medical devices using brain-computer interface technology Implantable neurostimulator with closed-loop function Sensing and Response Performance Testing Methods Brain‑computer interface medical device-Closed‑loop implantable National Medical Products Administration issued

Table of contents

Preface III 1.Scope 1 2 Normative References 1 3.Terms and Definitions 1 4.Test Method 2 4.1 Test Data Requirements 2 4.2 Perceived Performance Test 2 4.3 Closed-loop control stimulus-response test 4 4.4 EEG signal acquisition and processing algorithm test 5 Appendix A (Informative) Correspondence between different states of test signals and stimulus protocol modulation 7 Reference 9

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents". Drafting. Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents. This document was proposed by the National Medical Products Administration. This document is under the jurisdiction of the Active Implants Subcommittee of the National Technical Committee on Standardization of Surgical Implants and Orthopedic Devices. This document was drafted by. Shanghai Institute for Medical Device Testing, Beijing Pinchi Medical Equipment Co., Ltd., and Nanhu Brain-Computer Interaction Research Institute. Research Institute, Xuanwu Hospital of Capital Medical University, Tsinghua University, Hangzhou Jialiang Medical Technology Co., Ltd., Boruikang Technology (Shanghai) Co., Ltd. Jingyu Medical Technology (Suzhou) Co., Ltd., Shenzhen Yinghe Brain Science Co., Ltd., and Changzhou Ruishenan Medical Devices Co., Ltd. The main drafters of this document are. Hu Sheng, Liu Xun, Yu Hongyi, Chen Hao, Hao Hongwei, Wang Yueming, Xiong Botao, Zhao Guoguang, Shan Yongzhi, Wang Weiming, and Yu Huiling. Cao Peng, Zeng Yan, Xu Honglai, Huang Xiaoshan, Zhu Weiran, Deng Wei, Min Xiaoyi, Xin Sheng, An Shuqing. Medical devices using brain-computer interface technology Implantable neurostimulator with closed-loop function Sensing and Response Performance Testing Methods

1 Scope

This document describes an implantable neurostimulator with closed-loop functionality that utilizes brain-computer interface technology, based on the perception and response of neural signals. Performance testing methods. This document applies to implantable neurostimulators with closed-loop functionality that utilize brain-computer interface technology. Note. For implantable neurostimulators that do not have closed-loop functionality, their ability to sense neural signals (if any) shall be tested in accordance with the relevant clauses of this document. method.

2 Normative references

The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are listed below. For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies. document. YY/T 1987 Terminology for Medical Devices Employing Brain-Computer Interface Technology

3 Terms and Definitions

The terms and definitions defined in YY/T 1987 and the following terms and definitions apply to this document. 3.1 Brain-computer interface implanted neurostimulator Brain-computer interface technology is used to implant medical devices that provide electrical stimulation to the central nervous system. 3.2 Algorithm performance The efficiency and effectiveness of an algorithm when performing a specific task. Note. This typically includes the time required for the algorithm to execute, the memory or storage space required for the algorithm to execute, and the correctness of the algorithm in solving the problem. Rate or accuracy, stability and reliability of the algorithm when handling abnormal or noisy data, performance of the algorithm when handling datasets of different sizes, and computational efficiency. The speed of response and processing capabilities of the method in real-time applications. 3.3 stimulation threshold The critical value of electrical stimulation intensity that can control symptoms. Note. Generally includes a lower threshold and an upper threshold. The lower threshold refers to the minimum electrical stimulation intensity that can control symptoms, while the upper threshold refers to the intensity that can control symptoms while stimulating related accessory pathways. The maximum safe electrical stimulation intensity that minimizes the effect. 3.4 electrical stimulation strategy Electrical stimulation parameters and methods are developed and applied during treatment to optimize therapeutic effects and patient comfort.
...

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 1996-2025_English be delivered?


Answer: Upon your order, we will start to translate YY/T 1996-2025_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 1996-2025_English with my colleagues?


Answer: Yes. The purchased PDF of YY/T 1996-2025_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
Refund Policy Privacy Policy Terms of Service