YY/T 1230-2014 PDF English

Price & Delivery

US$259.00 · In stock · Download in 9 seconds
YY/T 1230-2014: Cystatin C test reagent kit
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Std IDVersionUSDBuyDeliver [PDF] inTitle (Description)
YY/T 1230-2014English259 Add to Cart 3 days [Need to translate] Cystatin C test reagent kit

Click to Preview a similar PDF

Basic data

Standard ID YY/T 1230-2014 (YY/T1230-2014)
Description (Translated English) Cystatin C test reagent kit
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C44
Classification of International Standard 11.100
Word Count Estimation 11,181
Date of Issue 6/17/2014
Date of Implementation 7/1/2015
Quoted Standard GB 3100; YY/T 0316; YY/T 0466.1
Regulation (derived from) China Food and Drug Administration in 2014 Bulletin No. 30
Issuing agency(ies) State Food and Drug Administration
Summary This Standard applies to the use of particle-enhanced immunoturbidimetric method of transmission in human serum or plasma cystatin C quantitative detection reagent (box), including manual reagents and on the semi-automatic biochemical analyzer used. This

YY/T 1230-2014: Cystatin C test reagent kit


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Cystatin C test reagent kit ICS 11.100 C44 People's Republic of China pharmaceutical industry standards Cystatin C assay reagent (kit) Issued on. 2014-06-17 2015-07-01 implementation China Food and Drug Administration released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. Please note that some of the content of this document may involve patents. Distribution of this document Institutions do not assume the responsibility to identify these patents. This standard was proposed by the China Food and Drug Administration. This standard by the national medical clinical laboratory testing and in vitro diagnostic systems for Standardization Technical Committee (SAC/TC136) centralized. This standard was drafted. Beijing Medical Device Testing, Beijing Tongren Hospital, Capital Medical University, Beijing nine strong biological technology Ltd., Roche Diagnostics (Shanghai) Co., Ltd. Guilin gifted Litvin Electronics Group Co., Ltd., Beijing Leadman Biochemistry Co., BIOSINO Biotechnology Co., Ltd.. The main drafters of this standard. Kang Juan, Liu Xiang Yi, Chen Yang, Tian Wei, Cai Hao Bin, Wang Lanzhen, Daylight Saving North Korea, Duhai Ou. Cystatin C assay reagent (kit)

1 Scope

This standard specifies the Cystatin C assay reagent (kit) requirements, test methods, labels, brochures, packaging, transportation and storage. This standard applies to the use of particle-enhanced immune transmission turbidity in human serum or plasma cystatin C quantitative detection test Agent (box), including manual reagents and on the semi-automatic biochemical analyzer used.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 3100 International System of Units and Its Application YY/T 0316 Medical Devices Risk Management for Medical Device Applications Symbols - Part 1 YY/T 0466.1 medical equipment used with medical device labels, labeling and information. General requirements

3 Requirements

3.1 Appearance In line with the provisions of the company's normal appearance requirements. 3.2 PACKING Not less than the indicated value. 3.3 reagent blank absorbance Producers meet the requirements specified. 3.4 Sensitivity Analysis Producers meet the requirements specified. 3.5 Linear Interval Reagent (box) linear in [0.40,7.50] mg/L range. a) The linear correlation coefficient ︱r︱ not less than 0.990; b) within [0.40,2.00] mg/L range, linearity deviation should not exceed ± 0.2mg/L; Within [2.01,7.50] mg/L range, linearity deviation should not exceed ± 10%. 3.6 Precision 3.6.1 Repeatability Repeat the test (1.00 ± 0.10) mg/L in the sample, the results of the coefficient of variation (CV) should not exceed 5%.
...