YY/T 0966-2014: Implants for surgery. Metallic materials. Unalloyed tantalum
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Std IDVersionUSDBuyDeliver [PDF] inTitle (Description)
YY/T 0966-2014English114 Add to Cart 3 days [Need to translate] Implants for surgery. Metallic materials. Unalloyed tantalum

Click to Preview a similar PDF

Basic data

Standard ID YY/T 0966-2014 (YY/T0966-2014)
Description (Translated English) Implants for surgery. Metallic materials. Unalloyed tantalum
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C35
Classification of International Standard 11.040.40
Word Count Estimation 6,633
Date of Issue 6/17/2014
Date of Implementation 7/1/2015
Quoted Standard ISO 6892.1-2009; ISO 643
Adopted Standard ISO 13782-1996, IDT
Regulation (derived from) China Food and Drug Administration in 2014 Bulletin No. 30
Issuing agency(ies) State Food and Drug Administration
Summary This standard applies to surgical implants pure tantalum sheet, strip, rod, wire. This standard specifies the chemical composition of surgical implants pure tantalum, microstructure, mechanical properties and the corresponding test methods.

YY/T 0966-2014: Implants for surgery. Metallic materials. Unalloyed tantalum


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Implants for surgery.Metallic materials.Unalloyed tantalum ICS 11.040.40 C35 People's Republic of China pharmaceutical industry standards Surgical implants of pure tantalum metal material (ISO 13782.1996, IDT) Issued on. 2014-06-17 2015-07-01 implementation China Food and Drug Administration released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard uses the translation method identical with ISO 13782.1996 "surgical implants pure tantalum metal material" (English version). Correspondence between the consistency of the standards of international documents and normative references of the following documents. --- GB/T 228.1-2010 tensile testing of metallic materials - Part 1. room temperature test methods (ISO 6892-1.2009, MOD) Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This standard was proposed by the China Food and Drug Administration. This standard by the national surgical implants and orthopedic instruments Standardization Technical Committee materials and orthopedic implants Technical Committee (SAC / TC110/SC1) centralized. This standard was drafted. Tianjin, the State Food and Drug Administration Medical Device Quality Supervision and Inspection Center, the State Food and Drug Pipe Authority for Medical Device Evaluation Center. The main drafters of this standard. Li Yuan, Fu Ruizhi, King Ming, Liu Bin, Dong Wenxing. Surgical implants of pure tantalum metal material

1 Scope

This standard specifies the characteristics of surgical implants pure tantalum sheet, strip, rod, wire and the corresponding test methods. Note. This standard specifies two grades of tantalum.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. ISO 6892-1.2009 Tensile testing of metallic materials - Part 1. room temperature test methods (Metalicmaterials-Tensile testing-Part 1. Methodoftestatroomtemperature) ISO 643 steel microscopy determination of apparent grain size (Steel-Micrographicdeterminationoftheapparentgrain size) Chemical composition 3 Accordance with the procedure prescribed in Chapter 6 of representative samples of alloy melting analysis, the chemical composition shall comply with the requirements in Table 1. all Element analysis method should be used ingot. Hydrogen analysis should be carried out after the final heat treatment and final surface treatment. Pure tantalum major elements and trace requirements in Table 1. Table 1 Chemical composition element Chemical composition (mass fraction) /% RO5200a RO5400b Carbon ≤0.010 ≤0.010 Oxygen ≤0.0150 ≤0.030 Nitrogen ≤0.010 ≤0.010 Hydrogen ≤0.0015 ≤0.0015 Niobium ≤0.100 ≤0.100 Iron ≤0.010 ≤0.010 Titanium ≤0.010 ≤0.010 Tungsten ≤0.05 ≤0.05 Molybdenum ≤0.020 ≤0.020 Silicon ≤0.0050 ≤0.0050 Nickel ≤0.010 ≤0.010 Tantalum Matrix matrix a electron beam or vacuum arc casting tantalum. b sintered tantalum.
...