US$174.00 · In stock · Download in 9 secondsYY/T 0919-2014: Non-active surgical implants. Joint replacement implants. Specific requirements for knee-joint replacement implants
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| YY/T 0919-2014 | English | 174 |
Add to Cart
|
3 days [Need to translate]
|
Non-active surgical implants. Joint replacement implants. Specific requirements for knee-joint replacement implants
|
Click to Preview a similar PDF
Basic data
| Standard ID | YY/T 0919-2014 (YY/T0919-2014) |
| Description (Translated English) | Non-active surgical implants. Joint replacement implants. Specific requirements for knee-joint replacement implants |
| Sector / Industry | Medical Device & Pharmaceutical Industry Standard (Recommended) |
| Classification of Chinese Standard | C35 |
| Classification of International Standard | 11.040.40 |
| Word Count Estimation | 9,997 |
| Date of Issue | 6/17/2014 |
| Date of Implementation | 7/1/2015 |
| Quoted Standard | YY/T 0640-2008; YY/T 0810.1; YY/T 0924.1; ISO 14243.1; ISO 14243.2; ISO 14243.3; ISO 21534-2007 |
| Adopted Standard | ISO 21536-2007, IDT |
| Regulation (derived from) | China Food and Drug Administration in 2014 Bulletin No. 30 |
| Issuing agency(ies) | State Food and Drug Administration |
| Summary | This Standard applies to knee replacement implants. This Standard specifies the expected performance of knee replacement implants, design attributes, materials, design evaluation, manufacturing, sterilization, packaging and information supplied by the man |
YY/T 0919-2014: Non-active surgical implants. Joint replacement implants. Specific requirements for knee-joint replacement implants
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Non-active surgical implants.Joint replacement implants.Specific requirements for knee-joint replacement implants
ICS 11.040.40
C35
People's Republic of China pharmaceutical industry standards
Active surgical implants - Joint replacement implants
Knee replacement implant-specific requirements
(ISO 21536.2007, IDT)
Issued on. 2014-06-17
2015-07-01 implementation
China Food and Drug Administration released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard uses the translation method identical with ISO 21536.2007 "active surgical implants - Joint replacement implants implanted knee replacement
Requirements for the material. "
This standard and ISO 21536.2007 as compared to only normative references have been adjusted to technical differences, in order to adapt to China
Technical conditions, the consistency of the correspondence between the standard international documents and normative references of the following documents.
YY/T 0640-2008 active surgical implants General requirements (ISO 14630.2005, IDT)
YY/T 0810.1-2010 surgical implant a total knee prosthesis - Part 1. Determination of fatigue properties of the tibial tray
(ISO 14879-1.2000, IDT)
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
This standard was proposed by the China Food and Drug Administration.
This standard by the national surgical implants and orthopedic instruments Standardization Technical Committee materials and orthopedic implants Technical Committee (SAC /
TC110/SC1) centralized.
This standard was drafted. China Medical Device Industry Association of Professional Committee of surgical implants, the State Food and Drug Administration, Tianjin Medical
Therapy Devices Quality Supervision and Inspection Center, Beijing Air Materiel Biam tech Co., Ltd., a Johnson Medical Devices (China) Co., Ltd.
The main drafters of this standard. Sun Jianwen, Yao Zhi repair, Zhang said, Dongshuang Peng, Liang Fanghui, Zhouxue Yu, Cheng Hongyuan.
Introduction
Standard relates to active surgical implants and related instruments are divided into three levels, involving the implant itself standard grades are as follows (a
Standards for the highest).
--- One. General requirements for passive surgical implants;
--- Class 2. Particular requirements for various types of active surgical implants;
--- Three levels. active surgical implants for a variety of special requirements.
The standard for the three standards, including a dedicated knee replacement implant requirements.
A standard YY/T 0640 contains apply to all active surgical implant requirements, but also prompt in the secondary and tertiary standards
There are some additional requirements.
Secondary standard applies to more limited class of active surgical implants, such as those designed for osteosynthesis, cardiovascular surgery, or joint home
In other implants.
To understand all the requirements, should the current minimum level of standard inspection began.
Active surgical implants - Joint replacement implants
Knee replacement implant-specific requirements
1 Scope
This standard specifies the knee replacement implant-specific requirements.
General safety, this standard specifies the expected performance, design attributes, materials, design evaluation, manufacturing, sterilization, packaging and manufacturers
Information, as well as the requirements, test methods.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
YY/T 0640-2008 active surgical implants General requirements (ISO 14630.2005, IDT)
YY/T 0810.1 surgical implant a total knee prosthesis - Part 1. Fatigue properties of knee tibial tray Determination
(YY/T 0810.1-2010, ISO 14879-1.2000, IDT)
YY/T 0924.1 Implants and total knee prosthetic components - Part 1. Classification, definitions and dimensions
(YY/T 0924.1-2014, ISO 7207-1.2007, MOD)
ISO 14243-1 Implants for surgery - Wear of total knee prostheses - Part 1. load control load and wear tester position
Shift parameters and the corresponding environmental conditions for test (Implantsforsurgey-Wearoftotalknee-jointprostheses-Part 1.
Loadinganddisplacementparametersforwear-testingmachineswithloadcontrolandcorresponding
enviromentconditionsfortest)
ISO 14243-2 Implants for surgery - Wear of total knee prostheses - Part 2. Methods of measurement (Implantsforsurgey-
Wearoftotalknee-jointprostheses-Part 2. Methodsofmeasurement)
ISO 14243-3 Implants for surgery - Wear of total knee prosthesis Part 3. displacement control load and wear tester position
Shift parameters and the corresponding environmental conditions for test (Implantsforsurgey-Wearoftotalknee-jointprostheses-Part 3.
Loadinganddisplacementparametersforwear-testingmachineswithdisplacementcontrolandcorre-
spondingenvironmentalconditionsfortest)
ISO 21534.2007 active surgical implants - Joint replacement implants - Particular requirements (Non-activesurgery-Jointre-
placementimplants-Particularrequirements)
3 Terms and Definitions
ISO 21534 and YY/T 0924.1 and the definition of the following definitions apply to this document.
3.1
Femoral component femoralcomponent
For fixing on the femur and total knee replacement articular surface replacement parts.
NOTE. These implants may be manufactured in one piece or set of components assembled by the user.
...