Cleanrooms and associated controlled environments. Biocontamination control. Part 2: Enaluation and interpretation of biocontamination data
|
Click to Preview a similar PDF
Basic data
| Standard ID | SN/T 3080.2-2012 (SN/T3080.2-2012) |
| Description (Translated English) | Cleanrooms and associated controlled environments. Biocontamination control. Part 2: Enaluation and interpretation of biocontamination data |
| Sector / Industry | Commodity Inspection Standard (Recommended) |
| Classification of Chinese Standard | C70 |
| Classification of International Standard | 13.040.35 |
| Word Count Estimation | 11,159 |
| Quoted Standard | SN/T 3080.1 |
| Adopted Standard | ISO 14698-2-2003, IDT |
| Regulation (derived from) | National Quality Inspection (2012) 237; industry standard filing Notice 2012 No. 9 (Total No. 153); |
| Issuing agency(ies) | General Administration of Customs |
| Summary | This standard specifies the cleanroom and associated controlled environments pollution control biofouling biological data evaluation and interpretation. For the clean room and associated controlled environments biological contamination data evaluation met |
SN/T 3080.2-2012: Cleanrooms and associated controlled environments. Biocontamination control. Part 2: Enaluation and interpretation of biocontamination data
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Cleanrooms and associated controlled environments.Biocontamination control.Part 2. Enaluation and interpretation of biocontamination data
People's Republic of China Entry-Exit Inspection and Quarantine Standards
Cleanrooms and associated controlled environments biofouling control
Part 2. Biological pollution data evaluation and interpretation
Part 2. Evaluationandinterpretationofbiocontaminationdata
(ISO 14698-2.2003, IDT)
Issued on. 2012-05-07
2012-11-16 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
SN/T 3080 "Cleanrooms and associated controlled environments Biological Pollution Control" is divided into two parts.
--- Part 1. Principles and methods;
--- Part 2. Biological pollution data evaluation and interpretation.
This section is SN/T 3080 Part 2.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method identical with ISO 14698-2.2003 "Cleanrooms and associated controlled environments Biological Pollution Control Part 2.
Biological pollution data evaluation and interpretation. "
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
This section proposed and managed by the National Certification and Accreditation Administration Committee.
This section was drafted by. People's Republic of China Tianjin Entry-Exit Inspection and Quarantine of Liaoning People's Republic of China
Bureau, People's Republic of China Zhejiang Entry-Exit Inspection and Quarantine Zhuhai People's Republic of China, People's Republic of China
Jiangsu Entry-Exit Inspection and Quarantine of Guangdong People's Republic of China, People's Republic of China Beijing Entry-Exit Inspection and Quarantine
Bureau, People's Republic of China Shandong Entry-Exit Inspection and Quarantine Yunnan People's Republic of China, Nankai University.
The main drafters of this section. Liu Wei, Zhang Haibin, Zhang Hongwei, Zhang Xia, Jiang Zheng, Bao Xiaoxia, such as thin clear, He Chenguang, Xue Feng, Huang Ji City, Wang Lin,
Xiao Xi Zhi, Liu Zhongmin, Gao Qi Li, Liu Yin, Kit Cheng.
Cleanrooms and associated controlled environments biofouling control
Part 2. Biological pollution data evaluation and interpretation
1 Scope
SN/T 3080 provisions of this part of the evaluation of clean rooms and associated controlled environments biofouling control biofouling and interpretation of data
method. Clean room and associated controlled environments of biological contamination data evaluation methods and biological contaminants taken control of risk areas
Active particle sampling method for evaluating the results to provide guidance. This standard is based on the collection of biological contamination control methods and biological sewage General
Dyed evaluation data provided. Evaluation can also be applied by other methods of obtaining biological contamination data.
This section applies to the evaluation and interpretation of cleanroom and associated controlled environment pollution control biological contamination biological data.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
SN/T 3080.1 Cleanrooms and associated controlled environments Biological Pollution Control Part 1. Principles and Methods
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Action level actionlevel
When the user control over the development of environmental standards, should take immediate interventions, including the investigation of the cause and corrective actions.
3.2
Warning level alertlevel
Set by the user in a controlled environment microbiological criteria may potentially occur under normal conditions departing early warning.
Note. when more than alarm criteria should focus on strengthening the inspection process.
3.3
Audit Trail audittrail
Related series of documents, records or information about the project retrospective.
3.4
Biological pollution biocontamination
Caused by the material, equipment, samples, surface, liquid, gas, or air pollution from the active particles.
3.5
Cleanroom cleanroom
Concentration of suspended particulates in the air controlled room. Its structure and purpose in some way will be introduced, generation and retention of particles in outdoor Save
To a minimum. If necessary, to deal with the clean room other relevant parameters (such as. temperature, humidity and pressure) control.
3.6
Data hierarchical datestratification
The data regrouped in order to discover and learn important trends and deviations.
...