Path:
Home >
SN/T >
Page73 > SN/T 2659-2010
Price & Delivery
US$339.00 · In stock · Download in 9 secondsSN/T 2659-2010: Monitoring codes for blackfly at frontier port
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| SN/T 2659-2010 | English | 339 |
Add to Cart
|
3 days [Need to translate]
|
Monitoring codes for blackfly at frontier port
|
Click to Preview a similar PDF
Basic data
| Standard ID | SN/T 2659-2010 (SN/T2659-2010) |
| Description (Translated English) | Monitoring codes for blackfly at frontier port |
| Sector / Industry | Commodity Inspection Standard (Recommended) |
| Classification of Chinese Standard | B16 |
| Classification of International Standard | 13.020 |
| Word Count Estimation | 13,118 |
| Date of Issue | 2010-11-01 |
| Date of Implementation | 2011-05-01 |
| Regulation (derived from) | National Quality Inspection (2010) 582 |
| Issuing agency(ies) | General Administration of Customs |
| Summary | This standard specifies the border crossings blackflies monitoring procedures, methods, content, statistical analysis and monitoring reports. This standard applies to border crossings blackflies monitored. |
SN/T 2659-2010: Monitoring codes for blackfly at frontier port
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Monitoring codes for blackfly at frontier port
People's Republic of China Entry-Exit Inspection and Quarantine Standards
Border crossings blackflies monitoring procedures
Issued on. 2010-11-01
2011-05-01 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. People's Republic of China Fujian Exit Inspection and Quarantine.
The main drafters of this standard. Fan Jianhua, Zhang Jianqing, Gao Bo, Cai Yishan, Zhang Shukeng.
Border crossings blackflies monitoring procedures
1 Scope
This standard specifies the border crossings blackflies monitoring procedures, methods, content, statistical analysis and monitoring reports.
This standard applies to monitor border crossings blackflies.
2 Terms and definitions
The following terms and definitions apply to this document.
2.1
Blackflies blackflies
Arthropoda, Insecta, Diptera, suborder long-horned, SIMULIIDAE in sucking blackflies have medical importance.
2.2
Blackflies monitoring monitoringofblackflies
Using a particular method for a population of ecological environment in the presence of blackflies composition, population dynamics, breeding grounds and other relevant impact
Factors continuous investigation system.
3 Preparations
3.1 Monitoring Group established
The Monitoring Group set up by the three to six-person, one person headed. Panel members should be professional and technical training, monitoring
During staff should not change.
3.2 Develop monitoring program
Including the identification of monitoring the content, timing, scope, location, method and monitoring appliances.
3.3 determine the scope of monitoring
Based on monitoring the border port area and its ecological environment to develop.
3.4 determine PLOT
At the border port living and working areas in particular jungle, brook, river, coastal adapted blackflies breeding habitat selection and set monitoring
Plots.
3.5 determine the monitoring time
In most parts of China, in spring (April) the weather gets warmer, blackflies begin its activities, to fall after the (November) the temperature dropped, reduced activity straight
To stop. Some provinces and cities in the south, may be blackflies Year. Monitoring specific start and end dates based on local and seasonal activities blackflies time may be, when the
Blackflies activities to occur before a late start to the end of blackflies activity disappears, a perennial blackflies activity areas monitored throughout the year. Monitoring period for each
Ten days, once every ten days were the fifth day. In case of rain and other inclement weather trouble monitoring, the monitoring time to properly extended.
...