SB/T 10594-2011: Technical management standard for central air-conditioning and ventilation system cleaning industry
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Std IDVersionUSDBuyDeliver [PDF] inTitle (Description)
SB/T 10594-2011English339 Add to Cart 3 days [Need to translate] Technical management standard for central air-conditioning and ventilation system cleaning industry

Click to Preview a similar PDF

Basic data

Standard ID SB/T 10594-2011 (SB/T10594-2011)
Description (Translated English) Technical management standard for central air-conditioning and ventilation system cleaning industry
Sector / Industry Domestic Trade Industry Standard (Recommended)
Classification of Chinese Standard P48
Classification of International Standard 91.140.30
Word Count Estimation 13,139
Date of Issue 7/7/2011
Date of Implementation 11/1/2011
Quoted Standard GB 19210; DB44/T 115
Regulation (derived from) Ministry of Commerce Notice 2011 No. 40
Issuing agency(ies) Ministry of Commerce of the People's Republic of China
Summary This standard specifies the air conditioning system of professional cleaning equipment, professional cleaning agency, cleaning procedures and cleaning process engineering supervision and acceptance testing after cleaning. This standard applies to all central air conditioning ventilation system cleaning services.

SB/T 10594-2011: Technical management standard for central air-conditioning and ventilation system cleaning industry




---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical management standard for central air-conditioning and ventilation system cleaning industry ICS 91.140.30 P48 Record number. 33171-2011 People's Republic of China domestic trade industry standard Central air conditioning ventilation system cleaning industry technical management norms Published on.2011-07-07 2011-11-01 implementation Published by the Ministry of Commerce

Content

Foreword III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Technical requirements for equipment 2 5 Technical and management requirements for professional cleaning organizations 4 6 Technical requirements for cleaning procedures 5 7 Engineering Environment Control 6 8 Repair and replacement after cleaning 7 9 Image of cleaning effect 7 10 Engineering Supervision and Testing Acceptance 7

Foreword

This standard was proposed by the Professional Committee of Cleaning Service Providers of the China Business Enterprise Management Association. This standard is managed by the Ministry of Commerce of the People's Republic of China. This standard was drafted. China Commercial Enterprise Management Association Cleaning Service Professional Committee, Zhongqing Jingye (Beijing) Environmental Science and Technology Research Institute, Shanghai Air Conditioning Duct Cleaning Association, Guangdong Indoor Environmental Health Industry Association, Shanghai Bangjie Environmental Protection Technology Co., Ltd., Beijing Oriental Jiechen Environmental Protection Technology Co., Ltd., Beijing Bozhan Technology Exchange Center, Tianjin Procter & Gamble Association. The main drafters of this standard. Li Jun, Wang Xinyun, Zhou Hailong, Dai Zizhu, Ding Lixing, Xu Wenhua, Yan Shiwei, Kong Zhaoli, Zhou Guanying, Gu Shiming, Shan Degang. Central air conditioning ventilation system cleaning industry technical management norms

1 Scope

This standard specifies the professional cleaning equipment, professional cleaning mechanism, cleaning operation procedures and engineering in the cleaning process of centralized air conditioning ventilation system. Supervision and inspection after cleaning. This standard applies to the cleaning services of all centralized air conditioning ventilation systems.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For documents that are not dated, the latest edition (including all amendments) applies to this document. GB 19210 Air conditioning ventilation system cleaning specification DB44/T 115 Central air conditioning circulating water and circulating cooling water quality standards

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 Cleaning technology cleaningtechnology Remove pollutants from the air-conditioning ducts and other components that are in contact with the conveying air, and accumulate pollutants in the air-conditioning cooling tower. And cleaning technology for disinfecting centralized air conditioning ventilation systems. 3.2 Dedicated cleaning equipment dedicatedcleaningequipments A general term for mechanical equipment, tools, instruments, and pollutant sampling equipment for air-conditioning ventilation systems. Centralized air conditioner Special cleaning equipment for ventilation system includes. internal sampling robot for air duct, hand-held detection and sampling equipment; centralized air conditioning ventilation system duct Cleaning robot, centralized air conditioning handheld cleaning device, centralized air conditioning pneumatic cleaning device, centralized air conditioning ventilation system, air duct pollutant trapping device Set; centralized air conditioning ventilation system equipment, component cleaning devices and centralized air conditioning ventilation system disinfection devices. 3.3 Duct detection robot ductingdetectionrobot 3.3.1 Visual inspection robot visualdetectionrobot A robotic device that carries a camera and can travel freely in a centralized air conditioning ventilation duct, mainly relying on the camera image to detect the air duct Internal cleaning. 3.3.2 Sampling detection robot samples-takingdetectionrobot Robotic equipment carrying a quantitative sampling system and freely traveling in a centralized air conditioning ventilation duct, mainly relying on quantitative sampling analysis Check the cleanliness inside the duct. 3.4 Visual cleaning The use of flexible shaft cleaning equipment, pneumatic cleaning equipment and other cleaning methods requires a camera to be fully visually cleaned.
...