RB/T 162-2017: Quality management systems-Cleaning and disinfecting services of central air conditioning ventilation system-Requirements
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Std IDVersionUSDBuyDeliver [PDF] inTitle (Description)
RB/T 162-2017English599 Add to Cart 6 days [Need to translate] Quality management systems-Cleaning and disinfecting services of central air conditioning ventilation system-Requirements

Click to Preview a similar PDF

Basic data

Standard ID RB/T 162-2017 (RB/T162-2017)
Description (Translated English) Quality management systems-Cleaning and disinfecting services of central air conditioning ventilation system-Requirements
Sector / Industry Chinese Industry Standard (Recommended)
Classification of Chinese Standard A00
Word Count Estimation 26,218
Date of Issue 2017-05-27
Date of Implementation 2017-12-01
Regulation (derived from) National Standard Division (2017) 64; Industry Standard Filing Announcement 2017 No. 7 (Total No. 211)
Issuing agency(ies) National Certification and Accreditation Administration

RB/T 162-2017: Quality management systems-Cleaning and disinfecting services of central air conditioning ventilation system-Requirements




---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Quality management system Centralized air conditioning and ventilation system cleaning and disinfection service requirements) ICS 03.120.20 A00 Record number. 58852-2017 People's Republic of China certification and recognition of industry standards Quality management system Central air conditioning ventilation system cleaning and disinfection service requirements Released on.2017-05-27 2017-12-01 implementation China National Certification and Accreditation Administration issued

Content

Foreword III Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Organizational Environment 2 4.1 Understanding the organization and its environment 2 4.2 Understanding the needs and expectations of interested parties 2 4.3 Determining the scope of the quality management system 3 4.4 Quality Management System and Process 3 5 Leadership 4 5.1 Leadership and Commitment 4 5.2 Guideline 4 5.3 Roles, responsibilities and authorities within the organization 5 6 Planning 5 6.1 Measures to address risks and opportunities 5 6.2 Planning of quality objectives and their implementation 5 6.3 Planning for change 6 6.4 Compliance obligations 6 7 support 6 7.1 Resources 6 7.2 Ability 7 7.3 Consciousness 8 7.4 Communication 8 7.5 written information 8 8 running 8 8.1 Planning and control of cleaning and disinfection services 8 8.2 Requirements for cleaning and disinfection services 9 8.3 Design and development of cleaning and disinfection services 9 8.4 Control of externally provided processes, products and services 9 8.5 Cleaning and disinfection service provided 10 8.6 Acceptance and delivery of cleaning and disinfection services 12 8.7 Control of unqualified output 12 9 Performance Evaluation 13 9.1 Monitoring, measurement, analysis and evaluation 13 9.2 Internal Audit 14 9.3 Management Review 14 10 Improvement 14 Appendix A (informative) The internal and external environment of the centralized air conditioning ventilation system for cleaning and disinfecting the organization 15 Appendix B (normative appendix) Test indicators and methods 18 Reference 21

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard is proposed and managed by the National Certification and Accreditation Administration. The framework of this standard is consistent with GB/T 19001-2016 "Quality Management System Requirements". This standard was drafted. Beijing World Standard Certification Center Co., Ltd., China Health Supervision Association, Beijing Dust Dragon Technology Development Co., Ltd. the company. The main drafters of this standard. Xu Tao, Li Yongbo, Xu Chao, Zhang Lili, Gai Ruyu, Sun Yaxin, Gao Jie, Zhao Tonggang, He Changling, Lu Yihong, Sun Zhujun, Wang Yuan.

Introduction

Centralized air conditioning ventilation system, especially large centralized air conditioning ventilation system can not get timely cleaning and disinfection or cleaning and disinfection The resulting harm to human health caused by air pollution has increasingly attracted people's attention. People are eager to pursue While improving the quality of life, the call for improving the environmental quality of working places and other public places, especially the air quality, is also coming. The more urgent, the air quality problem is directly related to everyone's safety and health. Central air conditioning ventilation system cleaning and disinfection is a must for health and energy saving Then choose. Only the centralized cleaning and disinfection of the centralized air conditioning ventilation system can solve the above-mentioned pollution problem of concentrated air conditioning ventilation system. And a series of problems such as wasting energy, can truly reflect the management concept of energy conservation, environmental protection and health, and implement people-oriented. The purpose of this standard is to establish a unified, industry-specific, and targeted quality management system requirements to guide and To help professional organizations engaged in cleaning and disinfection services for centralized air conditioning ventilation systems to establish a systematic, scientific, reasonable and operational quality Quantity management system, implement continuous improvement, achieve service management objectives, promote the standardization and improvement of centralized air conditioning ventilation system cleaning and disinfection service industry The overall quality of service and service level provide people with a safer and healthier environment. This standard is based on GB/T 19001-2016 "Quality Management System Requirements", combined with centralized air conditioning ventilation system cleaning and disinfection services The characteristics and requirements are standardized, which is the basic criterion for establishing a quality management system for the cleaning and disinfection organization of centralized air conditioning ventilation systems. This standard focuses on and adopts the current national standards, laws and regulations related to the cleaning and disinfection service industry of centralized air conditioning ventilation systems. And maintain coordination and consistency with it. This standard proposes the specific quality management system for cleaning and disinfection services of centralized air conditioning ventilation systems. Claim. When used for certification purposes, this standard should be used together with GB/T 19001-2016 "Quality Management System Requirements" to form a centralized air conditioner. Ventilation system cleaning and disinfection service quality management system requirements. Quality management system Central air conditioning ventilation system cleaning and disinfection service requirements

1 Scope

This standard specifies the terms and definitions, organizational environment, leadership role of the quality management system for cleaning and disinfection services of centralized air conditioning ventilation systems. Planning, support, operation, performance evaluation and improvement. This standard applies to the centralized air conditioning ventilation system cleaning and disinfection organization (hereinafter referred to as "organization") to establish, implement, maintain and improve its quality management The system can be used as the basis for self-evaluation and self-declaration of organizations, and can also be used as the quality of cleaning and disinfection services for centralized air-conditioning ventilation systems. The basis for the external evaluation and certification of the management system.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 19000-2016 Quality Management System Foundation and Terminology GB/T 19001-2016 Quality Management System Requirements GB 19210-2003 Air conditioning ventilation system cleaning specification GB/T 29044-2012 Heating and air conditioning system water quality HG/T 2387-2007 Industrial equipment chemical cleaning quality standards WS394-2012 Hygienic specification for centralized air conditioning and ventilation systems in public places WS/T 395-2012 Hygienic evaluation specification for centralized air conditioning ventilation system in public places WS/T 396-2012 Cleaning and disinfection specifications for centralized air conditioning ventilation systems in public places

3 Terms and definitions

The terms and definitions defined in GB/T 19000-2016, GB 19210-2003 and WS/T 396-2012 apply to this file. For ease of use, some of the terms and definitions in GB 19210-2003 and WS/T 396-2012 are repeated below. 3.1 Central air conditioning ventilation system centralairconditioningventilationsystem Concentration of air in order to meet the set requirements of room temperature or humidity, air temperature, humidity, cleanliness and airflow speed The sum of all equipment, pipes and accessories, instruments and meters that are handled, transported, and distributed. [WS/T 396-2012, Definition 3.1] 3.2 Central air conditioning ventilation system cleaning centralairconditioningventilationsystemcleaning Use some techniques or methods to remove air ducts, tuyères, air handling units (including air-conditioning fan coils) and other components from the air Contact surfaces and particulate matter and microorganisms accumulated in the air conditioning cooling tower. Note. Rewrite WS/T 396-2012, definition 3.2. 3.3 Centralized air conditioning ventilation system disinfection centralairconditioningventilationsystemdisinfecting Use physical or chemical methods to kill air conditioning ducts, cooling towers, air coolers, tuyères, air handling units (including air-conditioning fan coils) and others
...

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of RB/T 162-2017_English be delivered?


Answer: Upon your order, we will start to translate RB/T 162-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of RB/T 162-2017_English with my colleagues?


Answer: Yes. The purchased PDF of RB/T 162-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
Refund Policy Privacy Policy Terms of Service