NBSHT0824-2010 PDF English
Price & Delivery
US$319.00 · In stock · Download in 9 secondsNBSHT0824-2010: Standard test method for determination of additive elements in lubricating oils by inductively coupled plasma atomic emission spectrometry
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| NB/SH/T 0824-2010 | English | 319 | Add to Cart | 3 days [Need to translate] | Standard test method for determination of additive elements in lubricating oils by inductively coupled plasma atomic emission spectrometry |
Click to Preview a similar PDF
Basic data
| Standard ID | NB/SH/T 0824-2010 (NB/SH/T0824-2010) |
| Description (Translated English) | Standard test method for determination of additive elements in lubricating oils by inductively coupled plasma atomic emission spectrometry |
| Sector / Industry | Energy Industry Standard (Recommended) |
| Classification of Chinese Standard | E34 |
| Classification of International Standard | 75.100 |
| Word Count Estimation | 12,196 |
| Date of Issue | 2010-05-01 |
| Date of Implementation | 2010-10-01 |
| Quoted Standard | GB/T 4756; GB/T 17476; SH/T 0172; SH/T 0631; ASTM D4307; ASTM D6299 |
| Adopted Standard | ASTM D4951-2006, MOD |
| Regulation (derived from) | National Energy Board Notice No. 1 of 2010 |
| Issuing agency(ies) | National Energy Administration |
| Summary | This standard applies to the determination of unused lubricating oil additives and compound barium, boron, calcium, copper, magnesium, molybdenum, phosphorus, sulfur and zinc content. 1. 2 This precision applies in a solvent to 1% to 5% by mass diluted samples. 1. 3 Precision table shows the concentration range studied in the laboratory sample concentration range between, serve also applicable to the concentrations above and below the precision range of concentrations given in the table of the sample. The lower limit of the concentration can be determined depending on the sensitivity of the instrument and the sample dilution factor, the upper limit of the concentration can be determined depending on the highest concentration of the calibration curve and the sample dilution factor. 1. 4 at a wavelength of 180nm can be made at the instrument can measure sulfur content. 1. 5 standard uses SI units. 1. 6 standard involving certain hazardous materials, operations and equipment, but not for all safety related to this issue are recommendations. Therefore. Before the user of this standard is necessary to establish appropriate safety and protective measures, and determine the appropriate management system. |