Path:
Home >
JJ >
Page245 > JJG 798-2017
Price & Delivery
US$419.00 · In stock · Download in 9 secondsJJG 798-2017: Mechanical Couplers for Measurement of Bone Vibrators
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
JJG 798: Historical versions
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| JJG 798-2017 | English | 419 |
Add to Cart
|
4 days [Need to translate]
|
Mechanical Couplers for Measurement of Bone Vibrators
|
| JJG 798-1992 | English | 359 |
Add to Cart
|
3 days [Need to translate]
|
Verification Regulation of Standard artificial mastoids
|
Click to Preview a similar PDF
Basic data
| Standard ID | JJG 798-2017 (JJG798-2017) |
| Description (Translated English) | Mechanical Couplers for Measurement of Bone Vibrators |
| Sector / Industry | Metrology & Measurement Industry Standard |
| Classification of Chinese Standard | A59 |
| Word Count Estimation | 18,167 |
| Date of Issue | 2017-11-20 |
| Date of Implementation | 2018-05-20 |
| Older Standard (superseded by this standard) | JJG 798-1992 |
| Regulation (derived from) | AQSIQ Notice 2017 No. 103 |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine |
JJG 798-2017: Mechanical Couplers for Measurement of Bone Vibrators
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Bone oscillator measurement force coupler verification procedures)
National Metrology Verification Regulations of the People's Republic
Bone vibration measuring force coupler
Released on.2017-11-20
2018-05-20 implementation
The General Administration of Quality Supervision, Inspection and Quarantine issued
Replace JJG 798-1992
Focal Point. National Acoustic Metrology Technical Committee
Main drafting unit. China Institute of Metrology
Participated in drafting unit. Shanghai Institute of Metrology and Testing Technology
Chinese People's Liberation Army Medical Acoustics Measurement and Research Station
This procedure entrusts the National Acoustic Metrology Technical Committee to explain
The main drafters of this procedure.
Zhong Bo (China Institute of Metrology)
Cai Chenguang (China Institute of Metrology)
Participate in the drafters.
Deng Wei (Shanghai Institute of Metrology and Testing Technology)
Qi Fei (People's Liberation Army Medical Acoustics Measurement and Research Station)
Feng Xiujuan (China Institute of Metrology)
table of Contents
Introduction (II)
1 Scope (1)
2 References (1)
3 terms and units of measurement (1)
3.1 Bone vibration device (1)
3.2 Force Coupler (1)
3.3 alternating vibration force level (1)
3.4 Force Impedance (2)
3.5 force impedance level (2)
3.6 Force sensitivity (2)
3.7 Force sensitivity level (2)
4 Overview (2)
5 Metrological performance requirements (2)
5.1 Force Impedance Level (2)
5.2 Force impedance phase angle (3)
5.3 Force sensitivity level (3)
6 General technical requirements (3)
6.1 Appearance (3)
6.2 Marks (3)
7 Measuring instrument control (3)
7.1 Verification conditions (4)
7.2 Verification project (4)
7.3 Verification method (5)
7.4 Processing of verification results (8)
7.5 Verification cycle (8)
Appendix A Format of Internal Page of Verification Certificate and Verification Result Notice (9)
Introduction
This procedure is prepared in accordance with the requirements and format of JJF1002-2010 "Rules for the preparation of national metrological verification procedures", and
According to JJF1059.1-2012 "Measurement Uncertainty Evaluation and Representation", the measurement uncertainty of the verification results is evaluated.
This procedure mainly refers to IEC 60318-6.2007 Electroacoustic head and ear simulators Part 6. Bone vibration
Force measuring coupler (Electroacoustics-Simulatorsofhumanheadandear-Part 6.Me-
Mechanicalcouplerforthemeasurementofbonevibrators), for JJG 798-1992 Standard Simulation
The mastoid was revised. Compared with JJG 798-1992, the main technical changes except editorial changes are as follows.
--- Change the "standard simulated mastoid" to "bone oscillator measurement force coupler".
--- Added "terms and units of measurement".
--- Modified metering performance requirements. increased the two indicators of force impedance level and force impedance phase angle and their tolerances.
---In the "Metrics and main supporting equipment", replace the "measurement amplifier" with the "acoustic analyzer";
A charge amplifier and an LCR impedance meter have been added.
--- In the "validation method", the verification method of the force impedance level and the force impedance phase angle is added.
---Modified the format of the page in the verification certificate/verification result notice.
The previous versions of this procedure are released.
---JJG 798-1992.
Bone vibrometer measurement force coupler verification procedure
1 Scope
This procedure applies to the first verification, subsequent verification and in-use inspection of the force coupler for bone vibrometer measurement.
2 reference files
This procedure refers to the following documents.
JJG 338-2013 Charge Amplifier
JJF1001-2011 General Measurement Terms and Definitions
JJF1034-2005 Acoustic measurement terminology and definition
GB/T 3102.7 Acoustics and units
GB/T 3947 acoustic terminology
GB/T 15951-1995 Bone vibration measuring force coupler
Electroacoustic head and ear simulators - Part 6. Force coupling
Electroacoustics-Simulatorsofhumanheadandear-Part 6.Mechanicalcoupler
Forthemeasurementofbonevibrators)
For dated references, only the dated version applies to this Code; any undated quotation
The latest version (including all amendments) applies to this procedure.
3 terms and units of measure
This procedure uses the quantities and units specified in GB/T 3102.7.
JJF1001-2011, JJF1034-2005 and GB/T 3947 define the following terms and definitions for this
Procedure.
3.1 bone vibrator bonevibrator
The electrical oscillation signal can be converted into mechanical vibration and can be coupled to the skull structure of the human head (usually with milk)
Electromechanical transducers.
[IEC 60318-6.2007, Definition 3.1]
3.2 Force coupler mechanicalcoupler
A device capable of calibrating a bone vibrator that provides a gauge when coupled to a bone vibrator under conditions of a loaded static force
Fixed force impedance. Its internal electromechanical transducer measures the alternating vibrational force between the bone vibrator and the force coupler contact surface.
[IEC 60318-6.2007, definition 3.2]
Note. It can also be called artificialmastoid.
3.3 alternating vibration force level alternatingforcelevel
The square of the effective value of the alternating vibration force is divided by the square of the reference value (1μN), and the logarithm of the base 10 is used.
...
Tips & Frequently Asked Questions:
Question 1: How long will the true-PDF of JJG 798-2017_English be delivered?
Answer: Upon your order, we will start to translate JJG 798-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.
Question 2: Can I share the purchased PDF of JJG 798-2017_English with my colleagues?
Answer: Yes. The purchased PDF of JJG 798-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.
Question 3: Does the price include tax/VAT?
Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs):
List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?
Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
Question 5: Should I purchase the latest version JJG 798-2017?
Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 798-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.