Path:
Home >
JJ >
Page8 > JJG 778-2019
Price & Delivery
US$799.00 · In stock · Download in 9 secondsJJG 778-2019: Noise Level Statistical Analyzers
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
JJG 778: Historical versions
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| JJG 778-2019 | English | 799 |
Add to Cart
|
6 days [Need to translate]
|
Noise Level Statistical Analyzers
|
| JJG 778-2005 | English | RFQ |
ASK
|
5 days [Need to translate]
|
Verification regulation of noise level statistical analyzers
|
| JJG 778-1992 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
Verification Regulation of Noise Level Statistical Analyzers
|
Click to Preview a similar PDF
Basic data
| Standard ID | JJG 778-2019 (JJG778-2019) |
| Description (Translated English) | Noise Level Statistical Analyzers |
| Sector / Industry | Metrology & Measurement Industry Standard |
| Classification of Chinese Standard | A59 |
| Classification of International Standard | 17.140 |
| Word Count Estimation | 37,399 |
| Date of Issue | 2019 |
| Date of Implementation | 2020-03-31 |
| Issuing agency(ies) | State Administration for Market Regulation |
JJG 778-2019: Noise Level Statistical Analyzers
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Verification Regulation of Noise Statistics Analyzer)
National Measurement Verification Regulations of the People's Republic of China
Noise Statistics Analyzer
Published on December 31,.2019
2020-03-31 Implementation
Issued by the State Administration of Market Supervision and Administration
Verification Regulation of Noise Statistics Analyzer
Replace JJG 778-2005
Centralized unit. National Acoustic Metrology Technical Committee
Drafting unit. Chinese Academy of Metrology
Hunan Acoustic Instrument Control Technology Co., Ltd.
Hangzhou Aihua Instrument Co., Ltd.
State-owned 4380 Factory Jiaxing Branch
Fujian Academy of Metrology
This regulation is entrusted to the National Acoustic Measurement Technical Committee for interpretation
Drafters of this regulation.
Niu Feng (Chinese Academy of Metrology)
Liu Xiangheng (Hunan Acoustic Instrument Control Technology Co., Ltd.)
Xu Huan (Chinese Academy of Metrology)
Xiong Wenbo (Hangzhou Aihua Instrument Co., Ltd.)
Shu Guohua (State-owned 4380 Factory Jiaxing Branch)
Li Qun (Fujian Institute of Metrology)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2 References (1)
3 Terms and units of measurement (1)
3.1 Terminology (1)
3.2 Unit of measurement (2)
4 Overview (2)
5 Measurement performance requirements (3)
5.1 Indication sound level adjustment (3)
5.2 Frequency weighting (3)
5.3 linear (4)
5.4 Self-generated noise (4)
5.5 Time weighting F and S (4)
5.6 Sudden pronunciation response (4)
5.7 Repeated burst pronunciation response (5)
5.8 Calculation function (6)
6 General technical requirements (6)
6.1 Logo (6)
6.2 Functional requirements (6)
6.3 Appearance and power supply (6)
7 Control of measuring instruments (6)
7.1 Verification conditions (6)
7.2 Verification items (7)
7.3 Verification method (8)
7.4 Processing of verification results (16)
7.5 Verification period (16)
Appendix A Maximum allowable measurement uncertainty (17)
Appendix B. Other methods of frequency-weighted acoustic signal testing (18)
Appendix C. Internal page format of the verification certificate and verification result notice (20)
Appendix D Evaluation Examples of Measurement Uncertainty (30)
Introduction
This regulation is based on the rules and format given in JJF1002-2010 "Rules for Compiling National Measurement Verification Regulations"
prepared by.
This specification refers to the international standard IEC 61672-1.2013 "Electroacoustic Sound Level Meter Part 1.Specification"
And IEC 61672-3.2013 "Electroacoustic Sound Level Meter Part 3.Periodic Test", and also refer to IEC 61672-2.
2013 "Electroacoustic Sound Level Meter Part 2.Type Evaluation Test".
This regulation replaces JJG 778-2005 "Noise Statistics Analyzer". Compared with JJG 778-2005, the main technology
The changes are as follows.
--- Added the definition of the terms "cumulative percentage sound level" and "time average sound level";
---The "tolerance" of each measurement characteristic value is modified to "acceptance limit", and the qualified judgment is modified to the measured value and design
The deviation of the target does not exceed the applicable acceptance limit, and the measurement uncertainty does not exceed the applicable maximum allowable measurement uncertainty
Degree
--- Deleted the content of flat frequency response and overload indication;
--- Modified the static pressure conditions in the verification environmental conditions;
--- Increased the requirements for the amplitude sweep performance of the audio signal generator;
--- The "visual inspection" in the verification project was changed to "general technical requirements";
--- Deleted the "Instruction Manual" in the verification project;
--- Modified indication sound level adjustment, frequency weighting, level linearity, spontaneous noise, burst pronunciation response, repeated burst
Verification method of sound response and calculation function;
--- Added appendix "Other methods of frequency weighted acoustic signal test".
The release of previous versions of this regulation.
---JJG 778-2005;
---JJG 778-1992.
Verification Regulation of Noise Statistics Analyzer
1 Scope
This regulation is applicable to the first verification, subsequent verification and in-use inspection of level 1 and level 2 noise statistical analyzers.
2 Reference documents
This regulation refers to the following documents.
JJG 176-2005 Sound Calibrator
JJG 188-2017 sound level meter
JJG 482-2017 laboratory standard microphone (free field reciprocity method)
JJG 790-2005 Laboratory standard microphone (Coupling cavity reciprocity method)
JJF1001-2011 General Measurement Terms and Definitions
JJG 1019-2007 working standard microphone (coupling cavity comparison method)
JJF1034-2005 Acoustic metrology terms and definitions
JJF1059.1-2012 Evaluation and expression of measurement uncertainty
JJF1147-2006 Specification for acoustic characteristics calibration of anechoic and semi-anechoic rooms
JJF1293-2011 Calibration Specification for Electrostatic Exciter
GB/T 3102.7 Acoustic quantities and units
GB/T 3222.1-2006 Description, measurement and evaluation of acoustic environmental noise Part 1.Basic parameters
And evaluation methods
GB/T 3947-1996 Acoustic terms
GB/T 17312 Sound Level Meter Random Incident and Diffusion Field Calibration
IEC 61672-1.2013 Electroacoustic Sound Level Meter Part 1.Specification (Electroacoustics-Sound
levelmeters-Part 1.Specifications)
IEC 61672-2.2013 Electroacoustic sound level meter Part 2.Type evaluation test (Electroacous-
tics-Soundlevelmeters-Part 2.Patternevaluationtests)
IEC 62585 Electroacoustics Method for Determining the Correction Value of the Sound Field Meter Free Field Response (Electroacoustics-
Methodstodeterminecorrectionstoobtainthefree-fieldresponseofasoundlevelmeter)
For dated references, only the dated versions are applicable to this Regulation; for those without dates
The latest version (including all amendments) is applicable to this regulation.
3 Terms and units of measurement
3.1 Terminology
JJF1001-2011, JJF1034-2005, JJG 188-2017 and GB/T 3947-1996
The following terms and definitions apply to this regulation.
3.1.1 Cumulative percentage sound level percentilelevels
...