Path:
Home >
JJ >
Page6 > JJG 2032-2005
Price & Delivery
US$219.00 · In stock · Download in 9 secondsJJG 2032-2005: Verification Scheme of Measuring Instruments for Illuminance
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
JJG 2032: Historical versions
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| JJG 2032-2005 | English | 219 |
Add to Cart
|
3 days [Need to translate]
|
Verification Scheme of Measuring Instruments for Illuminance
|
| JJG 2032-1989 | English | 239 |
Add to Cart
|
2 days [Need to translate]
|
Verification Scheme of Measuring Instruments for Illuminance
|
Click to Preview a similar PDF
Basic data
| Standard ID | JJG 2032-2005 (JJG2032-2005) |
| Description (Translated English) | Verification Scheme of Measuring Instruments for Illuminance |
| Sector / Industry | Metrology & Measurement Industry Standard |
| Classification of Chinese Standard | A60 |
| Classification of International Standard | 17.180 |
| Word Count Estimation | 8,810 |
| Date of Issue | 2005-03-03 |
| Date of Implementation | 2005-06-03 |
| Older Standard (superseded by this standard) | JJG 2032-1989 |
| Summary | This standard applies to illumination verification of measuring instruments, which provides illumination national benchmark purposes, benchmarks included a full set of basic measuring instruments, the reference metrology parameters and by means of secondary standard, job reference, the standard to working measuring instruments deliver illumination unit money program, the basic test methods and uncertainty and so on. |
JJG 2032-2005: Verification Scheme of Measuring Instruments for Illuminance
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Scheme of Measuring Instruments for Illuminance
People's Republic of China National Metrology Verification System Table
Luminosity measuring instruments
2005-03-03 released
2005-06-03 implementation
General Administration of Quality Supervision, Inspection and Quarantine released
Luminosity measuring instruments calibration system table
Replacing JJG 2032-1989
The verification system table by the State General Administration of Quality Supervision, Inspection and Quarantine on March 03,.2005 approval,
And since June 3,.2005 shall come into force.
Administrative Organization. National Optical Metering Technology Committee
Main drafting units. China Institute of Metrology
The verification system table by the National Optical Metrology Technical Committee responsible for the interpretation
The system draftsman.
Liu Hui (China Institute of Metrology)
Gao Zhizhong (China Institute of Metrology)
table of Contents
1 Scope (1)
2 measurement standards (1)
2.1 Light intensity national benchmark (1)
2.2 light sub-benchmark (1)
2.3 light intensity work benchmarks (1)
3 measurement standards (2)
3.1 a light level (2)
3.2 secondary lighting standards (2)
3.3 standard light meter (2)
4 Working measuring instruments (2)
4.1 a light meter (2)
4.2 secondary light meter (2)
5 light meter measuring instrument system block diagram (2)
Luminosity measuring instrument verification system table *
1 Scope
This verification system table is suitable for the verification of illumination measurement instruments, which provides the use of the national standard of illumination
The complete set of basic measuring instruments included, the metrological parameters of the reference, and the reference to the standard, standard of work,
Work measuring instruments transmitted light intensity unit of the program, the basic test methods and uncertainty.
2 measurement standards
2.1 light national standards
2.1.1 Illumination The national reference is used to reproduce the magnitude of the illuminance unit, which is determined by the working standard of illumination, the standard illumination
Meter, a light level and two standards, the value passed to all levels of light meter, in order to ensure the value of the national light value
Unite. Illumination National benchmark recurrence range of illumination (10 ~ 3 × 103) lx.
2.1.2 Luminous intensity The national standard consists of the following measuring instruments. a group (not less than 7) luminous intensity of the reference lamp,
The distribution temperature of 2856K; light measurement device.
2.1.3 Illumination The expanded national uncertainty U of the baseline is 0.34%, including the factor k = 2 (the same applies below).
2.1.4 Luminosity The national baseline value is passed from the luminosity national baseline and is measured using absolute radiometry
Value calibration.
2.1.5 Illumination The best measurement capability of the national reference measuring device for transmitting the value is U = 0.21%.
2.2 light sub-benchmark
2.2.1 Illumination The national reference illumination value range (10 ~ 3 × 103) lx.
2.2.2 Luminosity The national benchmarks consist of the following measuring instruments. One set (not less than seven) Sub-standard of luminous intensity
Light, the distribution temperature of 2856K; light measurement device.
2.2.3 Luminosity The national benchmark for the expansion of uncertainty U is 0.37%.
2.2.4 Illumination The best measurement capability of the national sub-standard measuring device for transmitting the value is U = 0.21%.
2.2.5 Lightness The national sub-benchmark's value is transmitted by the photometric country's sub-benchmark.
2.3 light intensity work benchmarks
2.3.1 Light intensity Working standard is used to test the first and second level of illumination standard,
And calibrate the standard illuminance meter directly on the track. Light intensity working reference light intensity range (1 ~ 3 × 103) lx.
2.3.2 Working light illumination standards by the distribution of temperature of 2856K luminous intensity of the reference lamp and photometric measurement device
Composition, the standard lamp size should not be less than two, each not less than 5 lights.
Note. Since.2003, the original "Metrology Verification System" collectively referred to as the "Metrology Verification System Table."
2.3.3 Illumination The extended uncertainty U of the working reference is 0.40%.
2.3.4 Luminosity The benchmark for the use of the standard method of calibration by photometric photometer by the national benchmark or national deputy
Quasi transfer.
2.3.5 Luminosity The best measurement capability for the reference measurement device to transfer volume values is U = 0.50%.
...