US$329.00 · In stock · Download in 9 secondsJJG 185-2017: Standard Hydrophones in the Frequency Range 500 Hz to 1 MHz(Free-field Comparison Method)
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
JJG 185: Historical versions
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| JJG 185-2017 | English | 329 |
Add to Cart
|
3 days [Need to translate]
|
Standard Hydrophones in the Frequency Range 500 Hz to 1 MHz(Free-field Comparison Method)
|
| JJG 185-2004 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Locomotive speed meter testing procedures
|
| JJG 185-1997 | English | 359 |
Add to Cart
|
3 days [Need to translate]
|
Verification Regulation of Measuring Hydrophone in the Frequency Range 500Hz to 1 MHz
|
| JJG 185-1978 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Verification Regulation of Standard Hydrophone (Grade II)
|
Click to Preview a similar PDF
Basic data
| Standard ID | JJG 185-2017 (JJG185-2017) |
| Description (Translated English) | Standard Hydrophones in the Frequency Range 500 Hz to 1 MHz(Free-field Comparison Method) |
| Sector / Industry | Metrology & Measurement Industry Standard |
| Classification of Chinese Standard | A59 |
| Word Count Estimation | 14,167 |
| Date of Issue | 2017-11-20 |
| Date of Implementation | 2018-05-20 |
| Older Standard (superseded by this standard) | JJG 185-1997 |
| Regulation (derived from) | AQSIQ Notice 2017 No. 103 |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine |
JJG 185-2017: Standard Hydrophones in the Frequency Range 500 Hz to 1 MHz(Free-field Comparison Method)
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(500Hz ~ 1MHz standard hydrophone test procedures (free field comparison method))
National Metrology Verification Regulations of the People's Republic
500Hz~1MHz standard hydrophone
(free field comparison method)
Range500Hzto1MHz (Free-fieldComparisonMethod)
Released on.2017-11-20
2018-05-20 implementation
The General Administration of Quality Supervision, Inspection and Quarantine issued
500Hz~1MHz standard hydrophone
(free field comparison method) verification procedure
Replace JJG 185-1997
Focal Point. National Acoustic Metrology Technical Committee
Drafted by. China Testing Technology Research Institute
Institute of Acoustics
China Shipbuilding Industry Corporation Seventh Five-Year Research Institute
Shenzhen Institute of Metrology and Quality Inspection
This procedure entrusts the National Acoustic Metrology Technical Committee to explain
Drafters of this procedure.
Sun Lei (China Testing Technology Research Institute)
Mo Xiping (Institute of Acoustics, Chinese Academy of Sciences)
Zhao Han (Seventh Five-Year Research Institute of China Shipbuilding Industry Corporation)
Zhang Guoqing (Shenzhen Metrology and Quality Inspection Institute)
table of Contents
Introduction (II)
1 Scope (1)
2 References (1)
3 terms and units of measurement (1)
3.1 Hydrophone (1)
3.2 Standard hydrophone (1)
3.3 Free field sensitivity (1)
3.4 Free field sensitivity level (2)
3.5 Free field comparison method (2)
3.6 Electrical Transfer Impedance Mode (2)
3.7 Reference Center (2)
4 Overview (2)
5 Metrological performance requirements (2)
5.1 Free field sensitivity level (2)
5.2 Free field sensitivity level frequency response (2)
6 General technical requirements (3)
6.1 Appearance (3)
6.2 Marking and ex-factory information (3)
6.3 Normal work (3)
7 Measuring instrument control (3)
7.1 Verification conditions (3)
7.2 Verification project (4)
7.3 Verification method (5)
7.4 Processing of verification results (7)
7.5 Verification cycle (7)
Appendix A Format of Internal Page of Verification Certificate and Verification Result Notice (8)
Introduction
This procedure is a revision of JJG 185-1997 "500Hz ~ 1MHz measuring hydrophone".
The basis for this revision is the IEC 60565.2006 "Water Acoustic Hydrophone in the frequency range of 0.01 Hz to 1 MHz.
calibration".
Compared with JJG 185-1997, the main revisions are.
--- The name of the procedure was changed to "500Hz~1MHz standard hydrophone (free field comparison method)";
--- The terms used are based on the terms and definitions in JJF1001-2011 General Terms and Definitions;
---Add reference files;
--- Increase general technical requirements;
--- Remove the sensitivity (response) level and sensitivity (response) conversion table.
The previous versions of this procedure were released as follows.
---JJG 185-1997.
500Hz~1MHz standard hydrophone
(free field comparison method) verification procedure
1 Scope
This procedure applies to the first verification and follow-up of standard hydrophones used in the frequency range of 500 Hz to 1 MHz.
Verification and inspection in use.
2 reference files
This procedure refers to the following documents.
JJF1001-2011 General Measurement Terms and Definitions
JJF1034-2005 Acoustic measurement terminology and definition
GB/T 3102.7-1993 The amount and unit of acoustics
GB/T 3947-1996 acoustic terminology
IEC 60565.2006 Hydroacoustic hydrophone calibration from 0.01 Hz to 1 MHz (Underwater)
acoustics-Hydrophone-Calibrationinthefrequencyrange0.01Hzto1MHz)
For dated references, only the dated version applies to this Code; any undated quotation
The latest version (including all amendments) applies to this procedure.
3 terms and units of measure
This procedure uses the relevant terms in JJF1001-2011, JJF1034-2005, GB/T 3947-1996 and
definition.
This procedure uses the quantities and units specified in GB/T 3102.7-1993.
Note. Unless otherwise stated, all voltage values in this specification refer to the effective value.
3.1 hydrophone hydrophone
An electroacoustic transducer for receiving a hydroacoustic signal.
Note. due to different working principles, characteristics and construction, there are sound pressure, sound pressure gradient, undirected, pointed, piezoelectric, optical fiber, etc.
Listener.
[GB/T 3947-1996, definition 7.81]
3.2 standard hydrophone standardhydrophone
A stable, absolutely calibrated transducer for hydroacoustic metrology. Often used as a reference for establishing sound pressure in water
The standard is used to pass the sound pressure value.
[GB/T 3947-1996, definition 7.82]
3.3 Free field sensitivity free-fieldsensitivity
Receiving the open circuit voltage at the output of the transducer, and presenting itself at the center of the transducer before the introduction of the transducer in the sound field
The ratio of the sound pressure from the field.
...