JJF 1641-2017: Program of Pattern Evaluation of Ultraviolet--Visible Spectrophotometers
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Std IDVersionUSDBuyDeliver [PDF] inTitle (Description)
JJF 1641-2017English669 Add to Cart 5 days [Need to translate] Program of Pattern Evaluation of Ultraviolet--Visible Spectrophotometers

Click to Preview a similar PDF

Basic data

Standard ID JJF 1641-2017 (JJF1641-2017)
Description (Translated English) Program of Pattern Evaluation of Ultraviolet--Visible Spectrophotometers
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A60
Classification of International Standard 17.180
Word Count Estimation 29,297
Date of Issue 2017-09-26
Date of Implementation 2017-12-26
Quoted Standard JJG 178-2007; JJF 1001-2011; GB 4793.1-2007; GB/T 11606-2007
Regulation (derived from) General Administration of State Quality Inspection Announcement 2017 No. 78
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to the new product type evaluation work in the wavelength range of 190 mm to 1 000 mm, with continuously adjustable wavelength spectrophotometer.

JJF 1641-2017: Program of Pattern Evaluation of Ultraviolet--Visible Spectrophotometers


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(UV - visible spectrophotometer type evaluation outline) People's Republic of China National Measurement Specifications UV-visible spectrophotometer type evaluation outline Program of Pattern Evaluation Ultraviolet-Visible Spectrophotometers 2017-09-26 Posted 2017-12-26 Implementation General Administration of Quality Supervision, Inspection and Quarantine released UV-visible spectrophotometer Type evaluation outline Program of Pattern Evaluation Ultraviolet-Visible Spectrophotometers The focal point. National Physical Chemistry Metering Technology Committee The main drafting unit. China Institute of Metrology Participate in the drafting unit. Beijing Tongzhou Weipu Technology Co., Ltd. This specification entrusts the National Physical Chemistry Metrology Technical Committee responsible for the interpretation The main drafters of this specification. Li Lu Ming (China Institute of Metrology) Participate in the drafters. Sun Hongwei (Beijing Tongzhou Weipu Technology Co., Ltd.)

table of Contents

Introduction (Ⅲ) 1 Scope (1) 2 References (1) 3 Terms (1) 3.1 Spectrophotometer (1) 3.2 UV-visible spectrophotometer (1) 4 Overview (1) 5 Legal Management Requirements (1) 5.1 Unit of measure (1) 5.2 accuracy (maximum allowable error) requirements (1) 5.3 Marks (2) 6 measurement requirements (2) 6.1 Wavelength indication error (2) 6.2 wavelength repeatability (2) 6.3 transmittance indication error (2) 6.4 Transmission Repeatability (2) 6.5 Noise (2) 6.6 Drift (2) 6.7 Spectral bandwidth (2) 6.8 Baseline Flatness (2) 6.9 Stray light (2) 7 General technical requirements (3) 7.1 Appearance and preliminary examination (3) 7.2 Functional Requirements (3) 7.3 Low temperature test (3) 7.4 high temperature test (3) 7.5 Power supply voltage adaptability (3) 7.6 Crash test (3) 7.7 Drop test (3) 8 type evaluation item list (3) 9 to provide the number of prototypes and the use of the prototype (4) 9.1 provide the number of prototypes (4) 9.2 use of the prototype (4) 10 Test methods and conditions of test items and data processing and acceptance criteria (4) 10.1 Preparation before testing (4) 10.2 Appearance (5) 10.3 Wavelength indication error and wavelength repeatability (5) 10.4 transmittance error and repeatability (6) 10.5 Noise and Drift (7) 10.6 Spectral bandwidth (8) 10.7 Baseline Straightness (8) 10.8 Stray light (9) 10.9 Low temperature and high temperature adaptability (9) 10.10 Power supply voltage adaptability (10) 10.11 Crash test (10) 10.12 Drop Test (11) 11 Test items used in measuring instruments and equipment table (11) Appendix A UV-visible spectrophotometer type evaluation original records (13)

Introduction

This type evaluation outline based on JJF 1016 "Guidelines for the preparation of evaluation criteria for measuring instruments", JJF 1015 "meter Gage Type Evaluation and Type Approval General Specification "and JJF 1001" General Measurement Terms and Definitions ". The technical indicators of this type evaluation outline reference JJG178-2007 "UV, visible, near-infrared spectrophotometry Meter "and GB/T 11606-2007" analytical instruments environmental test methods "and other technical regulations. This type of evaluation outline for the first time released. UV-visible spectrophotometer type evaluation outline

1 Scope

This type of evaluation program for the wavelength range of 190nm ~ 1000nm, continuously adjustable wavelength of the spectrophotometer New product type evaluation work.

2 reference documents

This specification cites the following documents. JJG178-2007 "UV, visible, near-infrared spectrophotometer" JJF 1001-2011 "Common measurement terms and definitions" GB 4793.1-2007 "Safety requirements for electrical equipment for measurement, control and laboratory use" GB/T 11606-2007 "analytical instruments environmental test methods" For dated references, only the dated version applies to this specification; for undated references The latest version (including all amendments) applies to this specification.

3 Terms

3.1 spectrophotometer spectrophotometer Based on Lambert-Beer's law, the theory used for colorimetric analysis. 3.2 UV-visible spectrophotometer ultraviolet-visiblespectrophotometer The wavelength range of 190nm ~ 1000nm, wavelength continuously adjustable spectrophotometer.

4 Overview

UV - Vis spectrophotometer (hereinafter referred to as the instrument) is based on the material of UV - visible light radiation of choice Absorption and Lambert-Beer Laws Quantitative analysis of substances and qualitative identification of the instrument. The mathematical expression of Lambert-Beer's law is. A = -lg (I/Io) = - lgT = klc The physical meaning is that when a bundle of parallel monochromatic light perpendicular to the measured substance solution, the solution absorbance A And the concentration of light-absorbing material c and liquid layer thickness l is proportional to. The instrument is mainly composed of light source, monochromator, sample chamber, detector, signal processing and display and storage system.

5 legal management requirements

5.1 unit of measurement UV - visible spectrophotometer using legal units of measurement. 5.2 accuracy (maximum allowable error) requirements The accuracy of the instrument shall be in accordance with JJG178-2007 "UV, VIS, NIR Spectrophotometer" Provisions.
...