US$399.00 · In stock · Download in 9 secondsJJF 1518-2015: Calibration Specification for Medical Ultrasonic Field Measurement Systems
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| JJF 1518-2015 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Calibration Specification for Medical Ultrasonic Field Measurement Systems
|
Click to Preview a similar PDF
Basic data
| Standard ID | JJF 1518-2015 (JJF1518-2015) |
| Description (Translated English) | Calibration Specification for Medical Ultrasonic Field Measurement Systems |
| Sector / Industry | Metrology & Measurement Industry Standard |
| Classification of Chinese Standard | A59 |
| Classification of International Standard | 17.140 |
| Word Count Estimation | 17,152 |
| Date of Issue | 2015-04-10 |
| Date of Implementation | 2015-07-10 |
| Quoted Standard | JJF 1001-2011; JJF 1034-2005; JJG 1070-2011; JJF 1189-2008; GB 3102.7-1993; GB/T 16540-1996; IEC 62127-1; IEC 62127-2 |
| Regulation (derived from) | State Quality Inspection Administration Announcement 2015 No. 47 |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine |
| Summary | This Standard applies to calibrate medical ultrasonic sound field measurement system. |
JJF 1518-2015: Calibration Specification for Medical Ultrasonic Field Measurement Systems
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Medical Ultrasonic Field Measurement Systems
People's Republic of China National Metrology Technical Specifications
Medical ultrasonic field measurement system calibration specifications
Issued on. 2015-04-10
2015-07-10 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Medical ultrasonic field measurement system
Calibration Specification
Focal point. the National Committee of the acoustic measurement technology
Drafting unit. Henan Institute of Metrology
China Institute of Metrology
Zhengzhou Institute of Light Industry
This specification metering commissioned National Technical Committee is responsible for interpreting acoustics
Drafters of this specification.
Zhu Weimin (Henan Institute of Metrology)
Edge Wen Ping (China Institute of Metrology)
Cao Lingzhi (Zhengzhou University of Light Industry)
Qi Fang (Henan Institute of Metrology)
Fannai Yin (Henan Institute of Metrology)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 terminology and units of measurement (1)
3.1 The maximum time-averaged sound power (maximum power) (1)
4 Overview (1)
5 Metrological characteristics (2)
5.1 hydrophone positioning system (2)
5.2 hydrophone (2)
5.3 The maximum time-averaged sound power (2)
Calibration Condition 6 (2)
6.1 environmental conditions (2)
6.2 standards and other measuring equipment (2)
7 calibration items and calibration methods (2)
7.1 calibration items (2)
7.2 Calibration method (3)
8 calibration results (4)
8.1 Calibration Data Processing (4)
8.2 calibration certificate (5)
9 Recalibration time and space (5)
Appendix A calibration certificate (6)
Appendix B Uncertainty Evaluation Measurement Examples (8)
Introduction
This specification based JJF 1071-2010 "National Calibration Specifications writing rules" establishment. Reference
GB/T 16540-1996 "acoustic characterization of ultrasonic fields in the frequency range 0.5 ~ 15MHz and measuring hydrophone
Is Law ", hydrophone positioning system with reference to the technical requirements of the IEC 62127-1" Ultrasound - hydrophone highest first portion
Frequency to 40MHz medical ultrasound characteristics and measurement "(Ultrasonics-Hydrophones-Part 1.
Measurementandcharacterizationofmedicalultrasonicfieldsupto40MHz), the maximum time
Average sound power error reference to IEC 62127-2 "Ultrasound - hydrophone second part of the highest frequency to 40MHz
Ultrasonic Field Calibration "(Ultrasonics-Hydrophones-Part 2. Calibrationforultrasonicfieldsupto
40MHz) concerning medical ultrasonic field measurement system requirements.
This specification is the first release.
Medical ultrasonic field measurement system calibration specifications
1 Scope
This instruction applies to calibrate medical ultrasonic field measurement system.
2. References
This specification references the following documents.
JJF 1001-2011 common measurement terms and definitions
JJF 1034-2005 acoustic measurement terminology and definitions
JJG1070-2011 0.5MHz ~ 5MHz standard hydrophone
JJF 1189-2008 length measuring instrument calibration specification
GB 3102.7-1993 Quantities and units of acoustics
GB/T 16540-1996 acoustic characterization of ultrasonic fields in the frequency range 0.5 ~ 15MHz and its measurement
Hydrophone law
IEC 62127-1 ultrasound - the first part of hydrophones to measure the maximum frequency of 40MHz of medical ultrasonic fields
And features (Ultrasonics-Hydrophones-Part 1. Measurementandcharacterizationofmedical
ultrasonicfieldsupto40MHz)
IEC 62127-2 ultrasound - the second part of the hydrophone to the highest frequency of 40MHz ultrasound field calibration (Ul-
trasonics-Hydrophones-Part 2. Calibrationforultrasonicfieldsupto40MHz)
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments) applies to this specification.
3 terminology and units of measurement
The amount of this specification, the terms and definitions relating to the JJF 1001-2011, GB 3102.7-1993 prescribed
And units and the following terms and definitions.
3.1 The maximum time-averaged sound power (maximum power) maximumtemporal-averagetotaltransmitted
power
Refers to a specific area of time-averaged acoustic power of the scanning system is the total power of all the acoustic pulse.
4 Overview
Medical ultrasonic field measurement system is mainly used hydrophone measurement medical ultrasonic field characteristics of the device. Medical ultrasonic
Field measurement system consists of three-dimensional scanning positioning system, sink, hydrophones, hydrophone amplifier (if any) to
And sampling and data processing parts.
Sink a large enough space to meet the ultrasound transducer relative movement of the transducer and hydrophone between, on the move, Water
...