JJF 1287-2011: Calibration Specification for Clarity Test Equipment
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

JJF 1287: Historical versions

Std IDVersionUSDBuyDeliver [PDF] inTitle (Description)
JJF 1287-2011English329 Add to Cart 3 days [Need to translate] Calibration Specification for Clarity Test Equipment
JJF 1287-1990English519 Add to Cart 4 days [Need to translate] O.T.N. for Primary Standard of Direct Current(1A)

Click to Preview a similar PDF

Basic data

Standard ID JJF 1287-2011 (JJF1287-2011)
Description (Translated English) Calibration Specification for Clarity Test Equipment
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A60
Classification of International Standard 17.180
Word Count Estimation 14,15
Date of Issue 2011-06-14
Date of Implementation 2011-09-14
Quoted Standard JJG 245-2005; Chinese Pharmacopoeia (2010 edition)
Regulation (derived from) AQSIQ Announcement No. 90 of 2011
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to visible foreign matter Inspection Act (light inspection method) for clarity detector calibration.

JJF 1287-2011: Calibration Specification for Clarity Test Equipment


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Clarity Test Equipment People's Republic of China National Metrology Technical Specifications Clarity detector calibration specification Issued on. 2011-06-14 2011-09-14 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Clarity detector calibration specification TestEquip ment This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on June 14, 2011, and from From September 14, 2011 into effect. Focal point. the National Technical Committee on Optical metrology Main drafting unit. Liaoning Provincial Institute of Metrology China Testing Technology Research Institute Participated in the drafting unit. China Institute of Metrology This specification committee commissioned by the National Optical measurement technology is responsible for interpreting The main drafters of this specification. Aiming Ze (Liaoning Provincial Institute of Metrology) Li Xiaobin (China Testing Technology Research Institute) Zhang Mei (Liaoning Provincial Institute of Metrology) Drafters participate. Jiang Xiaomei (China Institute of Metrology)

table of Contents

1 Scope (1) 2. Referenced Documents (1) 3 Overview (1) 4 Metrological characteristics (2) Calibration Condition 5 (2) 5.1 Calibration environmental conditions (2) 5.2 Calibration Equipment (2) 6 calibration items and calibration methods (2) 6.1 Calibration before the test (2) The relative error of 6.2 Indication of illumination (2) 6.3 Uniformity light source (3) 6.4 Stability of the light source (3) 6.5 Timer indication error (3) 7 Calibration Results The expression (3) 8 Recalibration interval (4) Appendix A Measurement Uncertainty Example (5) Appendix B Calibration record format (7) Appendix C calibration certificate page format (9) Clarity detector calibration specification

1 Scope

This instruction applies to visible foreign matter inspection method (light detection method) of clarity detector calibration.

2 Citations

This specification references the following documents. JJG245-2005 light meter People's Republic of China Pharmacopoeia (2010 edition) When using this specification it should be noted that using the currently valid version of the documents cited.

3 Overview

Visible foreign matter is present in injections, ophthalmic pharmaceutical preparations in a liquid solution, under specified conditions, can be visually In observed insoluble material, typically having a particle size or length greater than 50μm. Clarity detector is based on light inspection method using visual methods, within the time specified in the illuminance and provisions, respectively In black and white background of the instruments to detect visible foreign matter. Clarity light detector system consists of a dedicated trichromatic illumination continuously adjustable fluorescent lamp composed of digital photos Meter part (the photoreceptor), time control systems. Figure 1 schematic clarity detector A- with a fluorescent light shading plate; B- reflective white background (the inside of the visor); C- non-reflective black background; D- white background and is not reflective of the bottom (for checking colored foreign matter); G- time display section; H- illumination display portion; E- one (or two) Illuminometers; F- clarity illuminance detector probe
...