Path:
Home >
MISC >
Page159 > JG/T 471-2015
Price & Delivery
US$489.00 · In stock · Download in 9 secondsJG/T 471-2015: Elastic sealants for insulating glass units of windows and curtain walls in building
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| JG/T 471-2015 | English | 489 |
Add to Cart
|
4 days [Need to translate]
|
Elastic sealants for insulating glass units of windows and curtain walls in building
|
Click to Preview a similar PDF
Basic data
| Standard ID | JG/T 471-2015 (JG/T471-2015) |
| Description (Translated English) | Elastic sealants for insulating glass units of windows and curtain walls in building |
| Sector / Industry | Building & Construction Industry Standard (Recommended) |
| Classification of Chinese Standard | P32 |
| Classification of International Standard | 91.1 |
| Word Count Estimation | 21,277 |
| Date of Issue | 2015-01-20 |
| Date of Implementation | 2015-07-01 |
| Quoted Standard | GB/T 1037; GB/T 2794; GB/T 3516-2006; GB/T 6040-2002; GB/T 9789-2008; GB/T 10125-2012; GB/T 10504; GB/T 11944-2012; GB/T 13477.2; GB/T 13477.5; GB/T 13477.6; GB/T 13477.8; GB/T 13477.17; GB 16776-2005; GB 50068-2001 |
| Regulation (derived from) | Ministry of Housing and Urban-Rural Development Notice 716 |
| Issuing agency(ies) | Ministry of Housing and Urban-Rural Development of the People's Republic of China |
| Summary | This Standard specifies the construction of hollow glass curtain wall windows and doors really elastic sealants terms and definitions, classification and marking requirements, test methods, inspection rules, marking, packaging, transportation and storage. This Standard applies to hollow glass curtain wall windows and doors sealed with two-component elastic adhesive sealant. |
JG/T 471-2015: Elastic sealants for insulating glass units of windows and curtain walls in building
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Elastic sealants for insulating glass units of windows and curtain walls in building
ICS 91.100
P32
People's Republic of China building industry standards
Building doors and windows curtain wall with hollow glass elastic sealant
2015-01-20 released
2015-07-01 implementation
Ministry of Housing and Urban-Rural Development, People's Republic of China released
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard proposed by the Ministry of Housing and Urban Standard and Design Institute.
This standard by the Housing and Urban-Rural Construction Products and Components Standardization Technical Committee.
This standard is drafted by. Zhengzhou Zhongyuan Applied Technology Research and Development Co., Ltd., China Academy of Building Research.
Participated in the drafting of this standard. Beijing Excellence Gold Control Technology Co., Ltd., Shanghai Branch Inspection Co., Ltd., Guangzhou Baiyun Chemical Industry
Co., Ltd., Sika (China) Co., Ltd., Guangzhou Jitai Chemical Co., Ltd., Guangdong Academy of Building Research, Henan Province Building Science Research
Hospital, Zhejiang Lexus Fine Chemical Co., Ltd.
The main drafters of this standard. Ma Qi Yuan, Zhang Deheng, Liu Ying, Cheng Peng, Jiang Qin Yi, Jiang Jinbo, Secretary Lin Gang, Chen Shilong, Lai Yande, Wang Tianshu,
Shi Zheng Jin, Wen Zhong.
Building doors and windows curtain wall with hollow glass elastic sealant
1 Scope
This standard specifies the terms and definitions hollow glass elastic sealants for building windows and doors curtain wall, classification and marking, requirements, test methods, seized
Rules, marking, packaging, transportation and storage.
This standard applies to the construction of windows and doors curtain wall insulating glass adhesive seal with two-component flexible sealant.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 1037 plastic film and sheet water vapor permeability test method cup method
Adhesives GB/T 2794 Determination of viscosity Single cylinder rotary viscometer method
Rubber, solvent extraction
GB/T 6040-2002 General rules of infrared spectrometry
GB/T 9789-2008 Metallic and other inorganic coatings usually condensation test conditions of sulfur dioxide corrosion
GB/T 10125-2012 artificial atmosphere corrosion test salt spray test
GB/T 10504 3A molecular sieve
GB/T 11944-2012 insulating glass
Test methods for building sealants - Part 2. Determination of density
Test methods for building sealants - Part 5. Determination of surface dry time
Test methods for building sealants - Part 6. Determination of fluidity
Test methods for building sealants - Part 8. Determination of tensile adhesion
Test methods for building sealants - Part 17. Determination of elastic recovery rate
Building structural silicone sealants
GB 50068-2001 Unified design reliability standards for building structures
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Building doors and windows curtain wall with hollow glass elastic sealant elasticsealantsforinsulatingglassunitsofwindowsand
curtainwalsinbuilding
To achieve the hollow glass unit around the elastic bonding components, with doors and windows for the curtain wall structure of the ultimate capacity of state design selection of strong
Degree of standard value, design value, modulus and other technical indicators of the rubber state of high elasticity sealant.
3.2
Initial shear modulus initialshearmodulus
The ability of the sealant to resist shear strain is characterized by the ratio of shear stress to shear strain in the initial stage of shear.
...