Path:
Home >
GB/T >
Page475 > GB/T 5548-2007
Price & Delivery
US$139.00 · In stock · Download in 9 secondsGB/T 5548-2007: Resin finishing agent -- Determination of the stability of solution after adding catalyst
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
GB/T 5548: Historical versions
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 5548-2007 | English | 139 |
Add to Cart
|
2 days [Need to translate]
|
Resin finishing agent -- Determination of the stability of solution after adding catalyst
|
| GB/T 5548-1985 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Resin finishing agent--Method of determination for the stability of solution after adding catalyst
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 5548-2007 (GB/T5548-2007) |
| Description (Translated English) | Resin finishing agent -- Determination of the stability of solution after adding catalyst |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | G55 |
| Classification of International Standard | 71.100.01; 87.060.10 |
| Word Count Estimation | 5,540 |
| Date of Issue | 2007-11-28 |
| Date of Implementation | 2008-06-01 |
| Older Standard (superseded by this standard) | GB/T 5548-1985 |
| Quoted Standard | GB/T 659; GB/T 672; GB/T 676; GB/T 1396; GB/T 6682 |
| Regulation (derived from) | China National Standard Approval Announcement2007 No.12 (Total No.112) |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard specifies the method for measuring the stability of a catalyst solution after resin finishing agent. This standard applies to the determination of a catalyst solution stability after finishing agent in the resin. |
GB/T 5548-2007: Resin finishing agent -- Determination of the stability of solution after adding catalyst
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Resin finishing agent. Determination of the sability of solution after adding catalyst
ICS 71.100.01; 87.060.10
G55
National Standards of People's Republic of China
Replacing GB/T 5548-1985
After the resin finishing agent plus catalyst
Determination of stability of solution
Posted 2007-11-28
2008-06-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard replaces GB/T 5548-1985 "solution stability of the resin finishing agent plus catalyst determination."
The main changes compared to 5548-1985 standard and GB/T as follows.
--- Standard name specification "add resin finishing agent solution was measured after the catalyst stability";
--- Define the scope of room temperature (1985 edition, Chapter 4; edition 6.1);
--- The results are expressed content specification (1985 edition, Chapter 4; edition 6.2);
--- Increasing the content of the test report (Chapter 7 of this edition).
The standard proposed by China Petroleum and Chemical Industry Association.
This standard by the National Standardization Technical Committee Dye (SAC/TC134) centralized.
This standard was drafted. Shenyang Chemical Research Institute.
The main drafters of this standard. Kiran Qin, Shen Jiong day.
This standard was first published in 1985.
After the resin finishing agent plus catalyst
Determination of stability of solution
1 Scope
This standard specifies the method for measuring the stability of solution after adding catalyst resin finishing agent.
This standard applies to the determination of the stability of the solution a catalyst for the resin finishing agent.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 659 chemical reagent ammonium nitrate
GB/T 672 chemical reagent magnesium chloride hexahydrate (magnesium chloride)
GB/T 676 chemical reagent acetic acid (glacial acetic acid)
GB/T 1396 chemical reagents sulfate
GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-1992, neq ISO 3696. 1987)
Principle 3
Adding an acidic reaction in aqueous solution of a certain amount of resin finishing agent, the catalyst is placed at a certain temperature to observe whether there is cloudy
Or precipitation. In time turbidity or precipitation indicates its stability.
4 Reagents and materials
Unless otherwise specified, use only water for the three confirmed analytically pure chemical reagents and GB/T 6682 stipulated.
4.1 Magnesium chloride solution. should be consistent with GB/T 672 provides mass fraction of 50%.
4.2 glacial acetic acid solution. should be consistent with GB/T 676 provides that the mass fraction of 98%.
4.3 ammonium nitrate solution. should be consistent with GB/T 659 provides mass fraction of 30%.
4.4 ammonium sulfate solution. should be consistent with GB/T 1396 regulations, mass fraction of 30%.
4.5 Aluminum nitrate solution. mass fraction of 30%.
5. Apparatus
5.1 Beaker. 400mL.
5.2 volumetric flask. 1000mL.
5.3 Pipette. 0.5mL, 5mL.
5.4 cylinder. 250mL.
5.5 Thermometer. (0 ~ 100) ℃.
6 Test methods
6.1 Determination of step
It weighs about 100g sample (accurate to 0.1g), diluted with water to 1000mL, removed from a solution of 4 parts of 245mL, respectively, on the
...