US$754.00 · In stock · Download in 9 secondsGB/T 44444-2024: Expression of performance of fluorometric oxygen analyzers in liquid media
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 44444-2024 | English | 754 |
Add to Cart
|
6 days [Need to translate]
|
Expression of performance of fluorometric oxygen analyzers in liquid media
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 44444-2024 (GB/T44444-2024) |
| Description (Translated English) | Expression of performance of fluorometric oxygen analyzers in liquid media |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | N53 |
| Classification of International Standard | 71.040.10 |
| Word Count Estimation | 38,316 |
| Date of Issue | 2024-09-29 |
| Date of Implementation | 2025-04-01 |
| Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 44444-2024: Expression of performance of fluorometric oxygen analyzers in liquid media
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 71.040.10
CCSN53
National Standard of the People's Republic of China
Performance of Liquid Fluorescence Oxygen Analyzer
(IEC 62703.2013, IDT)
Released on 2024-09-29
2025-04-01 Implementation
State Administration for Market Regulation
The National Standardization Administration issued
Table of Contents
Preface III
1 Scope 1
2 Normative references 1
3 Terms, definitions, quantities and units 2
3.1 Basic terms and definitions 2
3.2 General terms and definitions for equipment and operations 4
3.3 Terms and definitions for performance expression 5
3.4 Fluorescence Measurement Terms and Definitions 7
3.5 Instrument terms and definitions 8
3.6 Factors affecting the instrument 10
3.7 Quantities and units 11
4 Program Description 11
4.1 Instrument values and ranges 11
4.2 Working, storage and transportation conditions 11
4.3 Performance characteristics for which rated values are required 12
4.4 Uncertainty limits 12
5 Test methods 12
5.1 Test description 12
5.2 Influence 13
5.3 Working conditions 13
5.4 Calibration 13
5.5 Reference conditions 13
5.6 Test procedure 13
Appendix A (informative) Recommended values of performance influencing quantities in GB/T 6592 17
A.1 Overview 17
A.2 Climate conditions17
A.3 Mechanical conditions 19
A.4 Main power supply conditions 19
Appendix B (Informative) Calculation of performance characteristics based on drift test 22
Appendix C (Informative) Physical and chemical data of oxygen in water 23
C.1 Salinity and conductivity 23
C.2 Air Pressure and Altitude 23
C.3 Solubility of oxygen in water 24
C.4 Pressure conversion 30
Reference 31
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents"
Drafting.
This document is equivalent to IEC 62703.2013 "Performance Expression of Liquid Fluorescence Oxygen Analyzers".
Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents.
This document was proposed by the China Machinery Industry Federation.
This document is under the jurisdiction of the National Industrial Process Measurement, Control and Automation Standardization Technical Committee (SAC/TC124).
This document was drafted by. China Instrument Industry Association, Shanghai Institute of Metrology and Testing Technology, Shanghai Yidian Scientific Instrument Co., Ltd.
Co., Ltd., Mechanical Industry Analytical Instrument Product Quality Supervision and Inspection Center, Zhejiang Meiyi Intelligent Sensing Technology Co., Ltd., Jilin University, Taizhou City
Metrology Technology Research Institute, Shandong Dongrun Instrument Technology Co., Ltd., Fujian Shunchang Hongrun Precision Instrument Co., Ltd., Hebei Kerida Instrument
Technology Co., Ltd., Shanxi Zhongce Metrology Research Institute Co., Ltd., Xylem (China) Co., Ltd., Jiangsu Fangtian Electric Power Technology Co., Ltd.
Shanghai Leici Sensor Technology Co., Ltd., Chongqing Guohuan Lvyuan Technology Co., Ltd., Heilongjiang Province Metrology Verification and Testing Institute, Harbin
Industrial University.
The main drafters of this document are. Yan Hairong, Jiang Lei, Jin Chunfa, Jiang Xiaoyan, Chen Lijun, Gao Dejiang, Wang Suling, Ma Zheng, Chen Zhiyang, Hao Lihui,
Yang Weimin, Liu Jian, Ye Jiaxing, Pang Qing, Mei Xueqing, Ding Haiming, Zhang Zhiguo, Huang Yan.
Performance of Liquid Fluorescence Oxygen Analyzer
1 Scope
This document applies to fluorescent oxygen analyzers (hereinafter referred to as "instruments") for continuous determination of the partial pressure or concentration of dissolved oxygen in liquids.
It is suitable for the determination of ultrapure water, fresh water, drinking water, sea water, industrial or municipal sewage and liquids in industrial processes.
This document does not apply to instruments for the detection of oxygen in gases based on fluorescence.
The sensor unit of the instrument in contact with the measured medium contains a luminophore with an oxygen-permeable polymer membrane or contains other oxygen-permeable materials
(or matrix) of the luminescent body.
This document specifies terms and definitions, requirements and test methods for instruments.
This document is consistent with the provisions in GB/T 6592-2010 and IEC 60770.
This document is applicable to instruments based on online measurement technology and permanently installed indoors or outdoors.
Safety requirements are in accordance with IEC 61010-1.
The standard range for analog DC current signals for process control systems is given in IEC 60381-1.
For the method of selecting the impact quantity test value, please refer to the relevant provisions of IEC 60654.
The requirements for the preparation of instrument instruction manuals shall comply with IEC 61187.
For regulations on quantities, units and symbols, see ISO 80000-1.2022.
This document aims to.
--- Terms and conditions for specifying the performance characteristics of liquid fluorescence oxygen analyzers used for continuous determination of dissolved oxygen partial pressure or concentration in liquid media
definition;
--- Unify the methods for manufacturing and testing the functional characteristics of such instruments;
--- Tests and test methods required to determine functional characteristics;
---Provide basic documents in accordance with ISO 9001 quality assurance standards.
2 Normative references
The contents of the following documents constitute essential clauses of this document through normative references in this document.
For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to
This document.
GB/T 6592-2010 Performance indication of electrical and electronic measuring equipment (IEC 60359.2001, IDT)
Note. GB/T 2423 (all parts) Environmental testing [IEC 60068 (all parts)]
IEC 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use Part 1.General requirements
ments)
Note. GB 4793.1-2007 Safety requirements for electrical equipment for measurement, control and laboratory use Part 1.General requirements (IEC 61010-1.2001, IDT)
umentation
Note. GB/T 16511-1996 Random documents for electrical and electronic measuring equipment (IEC 61187.1993, IDT)
...