Path:
Home >
GB/T >
Page315 > GB/T 42269-2022
Price & Delivery
US$168.00 · In stock · Download in 9 secondsGB/T 42269-2022: Determination of pore size for membranes - Gas permeation method
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 42269-2022 | English | 168 |
Add to Cart
|
2 days [Need to translate]
|
Determination of pore size for membranes - Gas permeation method
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 42269-2022 (GB/T42269-2022) |
| Description (Translated English) | Determination of pore size for membranes - Gas permeation method |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | J77 |
| Classification of International Standard | 71.040.99 |
| Word Count Estimation | 13,198 |
| Date of Issue | 2022-12-30 |
| Date of Implementation | 2023-04-01 |
| Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 42269-2022: Determination of pore size for membranes - Gas permeation method
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 71.040.99
CCSJ77
National Standards of People's Republic of China
Separation Membrane Pore Size Test Method Gas Permeation Method
Posted on 2022-12-30
2023-04-01 Implementation
State Administration for Market Regulation
Released by the National Standardization Management Committee
foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules for Standardization Documents"
drafting.
Please note that some contents of this document may refer to patents. The issuing agency of this document assumes no responsibility for identifying patents.
This document is proposed and managed by the National Standardization Technical Committee of Separation Membrane (SAC/TC382).
This document was drafted by. Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Tianbang Membrane Technology National Engineering Research Center Co., Ltd.,
Shandong Zhaojin Motian Co., Ltd., Hohai University, Sanda Membrane Technology (Xiamen) Co., Ltd., Best Instrument Technology (Beijing) Co., Ltd.,
Foshan Shunde District Quality and Technical Supervision Standards and Coding Institute, Guangzhou Advanced Technology Research Institute, Tianjin Motianmo Technology Co., Ltd., Zhejiang
Tailin Life Science Co., Ltd., Beijing Origin Water Separation Membrane Technology Co., Ltd., Hubei Jufu Membrane Technology Co., Ltd., Anhui Zhongke Xinyang Membrane
Technology Co., Ltd., CNOOC Energy Conservation and Environmental Protection Service Co., Ltd., Xi'an Eagle Aviation Technology Co., Ltd., Suzhou Fumiao Membrane Technology Co., Ltd.
Co., Ltd., Chongqing Osisis Environmental Protection Technology Co., Ltd., Sinochem (Ningbo) Runwo Membrane Technology Co., Ltd., Wanhua Chemical Group Co., Ltd.
Division, Zhejiang Jinmembrane Environmental Technology Co., Ltd., Gongqi (Zhengzhou) Environmental Technology Co., Ltd., Shenzhen National Research Institute of High Performance Medical Devices Co., Ltd.
Company, Hangzhou Kebaite Filter Equipment Co., Ltd., Zhejiang Dongou Filter Manufacturing Co., Ltd., Zhejiang Jingyuan Membrane Technology Co., Ltd., Zhejiang
Jianghuiyong New Material Co., Ltd., Hunan Aowei Technology Co., Ltd., Jiangsu Nuolai Smart Water Equipment Co., Ltd., Tianjin Motianmo Engineering Co., Ltd.
Cheng Technology Co., Ltd., Chongqing Moore Water Treatment Equipment Co., Ltd.
The main drafters of this document. Wang Lina, Cao Yiming, Xu Youyou, Wang Xinyan, Gong Haichen, Qiu Zhuguo, Liu Jianfeng, Wang Fang, Chen Shunquan,
Lu Xiaolong, Zou Kailun, Pei Zhiqiang, Wu Fugen, Wang Xiaolin, Liu Minghui, Xue Jin, Cai Ting, Ye Yang, Cao Chun, Wei Hanhui, Xu Yinong, Wang Tao, Zheng Hairong,
Zhu Yang, Chen Benhua, Shen Xufeng, Cao Yi, Hu Qunhui, Yu Shuili, Wang Hanyi, Ma Bing, Jie Xingming, Gao Xu, Zhang Hongbin, Chen Jie, Xi Xuejie, Ma Lanyun.
Separation Membrane Pore Size Test Method Gas Permeation Method
1 Scope
This document describes a method for determining the average pore size of separation membranes using the gas permeation method.
This document is applicable to the test of the average pore diameter of flat membranes and hollow fiber membranes with a pore diameter of 0.01 μm to 0.2 μm in a dry state.
The separation membrane of the formula can be implemented with reference.
This document is applicable to the test gas that is nitrogen, and other non-condensable gases, such as He, H2, O2, Ar, etc., can refer to this document for implementation.
2 Normative references
The contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, dated references
For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to
this document.
GB/T 2918-2018 Standard environment for conditioning and testing of plastic specimens
GB/T 8979-2008 Pure Nitrogen, High Purity Nitrogen and Ultra Pure Nitrogen
GB/T 20103-2006 Membrane Separation Technical Terminology
3 Terms and Definitions
The following terms and definitions defined in GB/T 20103-2006 apply to this document.
3.1
flat membrane flatmembrane
The appearance is a flat or paper-like film.
NOTE. Flat sheet membranes usually have a support layer (e.g., non-woven fabric) for the preparation of plate-and-frame, pleated, and spiral-wound membrane elements.
[Source. GB/T 20103-2006, 2.1.27]
3.2
Hollow fiber membrane holowfibermembrane
The appearance is a fibrous, hollow, self-supporting membrane.
Note. For reverse osmosis membranes, the cortex is on the outer surface; for ultrafiltration and microfiltration membranes, the cortex is on the inner surface, outer surface, or inner and outer surfaces.
[Source. GB/T 20103-2006, 2.1.28]
3.3
Aperture porediameter
Nominal membrane pore diameter.
[Source. GB/T 20103-2006, 2.1.31]
3.4
Average pore size meanporesize
The average pore size of the membrane surface.
[Source. GB/T 20103-2006,5.1.6]
...