Path:
Home >
GB/T >
Page165 > GB/T 3413-2008
Price & Delivery
US$229.00 · In stock · Download in 9 secondsGB/T 3413-2008: Instrument for dam monitoring -- Embedded cu resistance thermometer
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
GB/T 3413: Historical versions
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 3413-2008 | English | 229 |
Add to Cart
|
3 days [Need to translate]
|
Instrument for dam monitoring -- Embedded cu resistance thermometer
|
| GB/T 3413-1994 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Embedded Cu resistance thermometer
|
| GB 3413-1982 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Embedded Cu resistance thermometer
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 3413-2008 (GB/T3413-2008) |
| Description (Translated English) | Instrument for dam monitoring -- Embedded cu resistance thermometer |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | N93 |
| Classification of International Standard | 07.060 |
| Word Count Estimation | 10,116 |
| Date of Issue | 2008-11-21 |
| Date of Implementation | 2009-02-01 |
| Older Standard (superseded by this standard) | GB/T 3413-1994 |
| Quoted Standard | GB/T 191; GB/T 5080.7; GB/T 6388; GB 9969; GB/T 15464; GB/T 50279; JJG 130 |
| Regulation (derived from) | Announcement of Newly Approved National Standards No. 19 of 2008 (No. 132 overall) |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard specifies the copper resistance thermometer embedded product structure, specifications and parameters, technical requirements, test methods, inspection rules, signs and instructions and packaging, transportation and storage requirements. This standard applies to soil buried in concrete buildings and structures with enamelled round copper wire as the internal temperature sensing element of the thermometer. |
Similar standards
GB/T 3411.1|
GB/T 3413-2008: Instrument for dam monitoring -- Embedded cu resistance thermometer
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Instrument for dam monitoring. Embedded cu resistance thermometer
ICS 07.060
N93
National Standards of People's Republic of China
Replacing GB/T 3413-1994
Dam monitoring instruments
Embedded copper resistance thermometer
Posted 2008-11-21
2009-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard is GB/T 3413-1994 "copper resistance thermometer embedded" amendments.
This standard compared with GB/T 3413-1994, the main changes are as follows.
--- Increased Chapter 3 Terms and definitions;
--- In Chapter 5, we modify the requirements for long-term stability;
--- In Chapter 5, we modify the requirements of mechanical environment adaptability;
--- In Chapter 5 adds reliability requirements;
--- In Chapter 9 increased storage environmental requirements;
--- Complements the inspection rules and signs, packaging, transportation and storage requirements.
This standard is proposed and administered by the People's Republic of China Ministry of Water Resources.
This standard is mainly drafted by. MWR hydrological instruments and geotechnical engineering Instrument Quality Supervision and Testing Center, the State Power Company Nanjing
Electric Power Automation Equipment Factory, Ministry of Water Resources Hydrology Nanjing Hydraulic Research Institute of Automation.
Participated in the drafting of this standard. the country's industrial production permit office hydrological instruments and geotechnical engineering Instrument Examination Department.
The main drafters of this standard. Peng Helin, Chaconne, Zhang Dekang.
This standard replaces the standards previously issued as follows.
--- GB/T 3413-1994.
Dam monitoring instruments
Embedded copper resistance thermometer
1 Scope
This standard specifies the embedded product mix, specifications and parameters, technical requirements, test methods, inspection rules copper resistance thermometers, signs
And operating instructions and packaging, transportation and storage requirements.
This standard applies to embedded in concrete buildings and soil structure internally enamelled round copper wire as the thermometer temperature sensing element.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 191 Packaging - Pictorial signs
GB/T 5080.7 Equipment reliability testing efficiency constant failure rate assumption under the MTBF of test plans
GB/T 6388 transport package shipping mark
GB 9969.1 Instructions General Industrial Products
GB/T 15464 instrumentation packaging technology
GB/T 50279 Standard for fundamental terms of geotechnical engineering
JJG130 work with liquid glass thermometer test procedures
3 Terms and Definitions
GB/T 50279 and established the following terms and definitions apply to this standard.
3.1
Embedded in concrete buildings and soil structure internally enamelled round copper wire as the temperature sensor temperature sensing element.
3.2
Each resistance thermometer temperature changes corresponding to the value 1 ohm.
3.3
The time required to reach Shi thermometer temperature measuring point corresponding to the resistance value.
4 product mix, specifications and parameters
4.1 Product Structure
Embedded copper resistance thermometers (hereinafter referred to as a thermometer) temperature sensing element, the sealed housing and cable outlet three major components, such as
1 shown in FIG.
...