Path:
Home >
GB/T >
Page85 > GB/T 32121-2015
Price & Delivery
US$169.00 · In stock · Download in 9 secondsGB/T 32121-2015: Determination of 4-(aminomethyl) cyclohexanecarboxylic acid (tranexamic acid) in toothpaste -- HPLC-MS/MS
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 32121-2015 | English | 169 |
Add to Cart
|
3 days [Need to translate]
|
Determination of 4-(aminomethyl) cyclohexanecarboxylic acid (tranexamic acid) in toothpaste -- HPLC-MS/MS
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 32121-2015 (GB/T32121-2015) |
| Description (Translated English) | Determination of 4-(aminomethyl) cyclohexanecarboxylic acid (tranexamic acid) in toothpaste -- HPLC-MS/MS |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | Y43 |
| Classification of International Standard | 71.100.40 |
| Word Count Estimation | 8,887 |
| Date of Issue | 2015-10-09 |
| Date of Implementation | 2016-05-01 |
| Quoted Standard | GB/T 6379.1; GB/T 6379.2; GB/T 6682 |
| Regulation (derived from) | National Standard Announcement 2015 No.31 |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard specifies the determination toothpaste 4-amino-methyl cyclohexane carboxylic acid (tranexamic acid) was determined by high performance liquid chromatography tandem mass spectrometry This standard applies to toothpaste 4-amino-methyl cyclohexane carboxylic acid (tranexamic acid) is. The standard detection limit: 0.3 ��g/g; quantitative limit: 1.0 ��g/g. |
GB/T 32121-2015: Determination of 4-(aminomethyl) cyclohexanecarboxylic acid (tranexamic acid) in toothpaste -- HPLC-MS/MS
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of 4- (aminomethyl) cyclohexanecarboxylic acidtranexamic acid) in toothpaste - HPLC-MS/MS
ICS 71.100.40
Y43
National Standards of People's Republic of China
Toothpaste 4-amino-methyl cyclohexane carboxylic acid (tranexamic acid) of
High performance liquid chromatography tandem mass spectrometry
Determinationof4- (aminomethyl) cyclohexanecarboxylicacid
(Tranexamicacid) intoothpaste-HPLC-MS/MS
Issued on. 2015-10-09
2016-05-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
The standard proposed by China National Light Industry Council.
The standard oral care products by the National Technical Committee of Standardization Technical Committee toothpaste (SAC/TC492/SC1) centralized.
This standard was drafted. Dalian City Product Quality Supervision, Inspection (National Day of Product Quality Supervision and Inspection Center), Dalian Standard Testing Technology
Art research center.
The main drafters of this standard. Maoxi Qin, Zheng Shunli Hu Xia, Ren Guojie, Li Chunling, Dongguang Bin.
Toothpaste 4-amino-methyl cyclohexane carboxylic acid (tranexamic acid) of
High performance liquid chromatography tandem mass spectrometry
1 Scope
This standard specifies the toothpaste of 4-aminomethyl cyclohexane carboxylic acid (tranexamic acid) was determined by high performance liquid chromatography tandem mass spectrometry
This standard applies to the determination of toothpaste 4-amino-methyl cyclohexane carboxylic acid (tranexamic acid) is.
The standard method detection limit. 0.3μg/g; lower limit of quantification. 1.0μg/g.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 6379.1 measurement methods and results of Accuracy (trueness and precision) - Part 1. General principles and definitions
GB/T 6379.2 measurement methods and results of Accuracy (trueness and precision) - Part 2. Determine the standard measurement method to repeat
Of the basic methods of reproduction
Laboratory use specifications and test methods GB/T 6682 Analysis
Method 3 points
Toothpaste first dispersed aqueous solution, methylene chloride was then added, vortexed and centrifuged to remove most of the solids of a surfactant, the supernatant
And 3% aqueous formic acid under acidic conditions after mixing too strong cation solid-phase extraction column, 1.5% aqueous formic acid leaching bed, 20% aqueous methanol
Solution (containing 2% aqueous ammonia) to give the object eluent after 3% formic acid aqueous solution and set the volume, separated by a liquid chromatography tandem mass spectrometry measurement
Set the standard curve external standard. Phase extraction process because the target was unstable at low concentrations, extraction and solid required to EDTA
(EDTA) disodium as a stabilizer for protection.
4 standard materials and reagents
Unless otherwise specified, the reagents were of analytical grade water to comply with GB/T 6682 with a water laboratory.
4.1 Standards
Table 1 Standard Substance Information
Title compound 4-amino-methyl-cyclohexanecarboxylic acid
English name of 4- (aminomethyl) cyclohexanecarboxylicacid, tranexamicacid
Alias \u200b\u200btranexamic acid, tranexamic acid, tranexamic acid
CAS No. 1197-18-8
Formula C8H15NO2
...