Path:
Home >
GB/T >
Page169 > GB/T 28853-2012
Price & Delivery
US$439.00 · In stock · Download in 9 secondsGB/T 28853-2012: Thermostatic baths and circulators -- Heated circulators
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 28853-2012 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Thermostatic baths and circulators -- Heated circulators
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 28853-2012 (GB/T28853-2012) |
| Description (Translated English) | Thermostatic baths and circulators -- Heated circulators |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | N61 |
| Classification of International Standard | 19.040 |
| Word Count Estimation | 19,174 |
| Quoted Standard | GB/T 191-2008; GB/T 2829-2002; GB 4793.1-2007; GB 4793.6-2008; GB/T 9969-2008; GB/T 16895.10-2010; JB/T 9512-1999; GB/T 17248.3- 1999 |
| Regulation (derived from) | National Standards Bulletin 2012 No. 28 |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard specifies the classification of high-temperature thermostat circulation device, conditions, requirements, test methods, inspection rules, marking, packaging, transportation, storage and accompanying documents. This standard applies not equip |
GB/T 28853-2012: Thermostatic baths and circulators -- Heated circulators
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Thermostatic baths and circulators. Heated circulators
ICS 19.040
N61
National Standards of People's Republic of China
Thermostatic bath and circulating means
High temperature thermostat circulation means
Issued on. 2012-11-05
2013-02-15 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Category 1
4 Conditions 2
Environmental Conditions 2 4.1
4.2 Supply Condition 2
2 4.3 liquid heat transfer medium
5 Requirement 2
5.1 appearance and structure 2
5.2 Technical Performance 3
5.3 Safety and environmental protection 3
6 Test Method 4
6.1 Main test instruments and equipment 4
6.2 Test conditions 5
6.3 Test appearance and structure 7
6.4 Operating temperature range Test 7
6.5 Minimum extended operating temperature Test 7
6.6 Temperature fluctuation test 7
6.7 circulating pump maximum flow rate test 8
6.8 circulating pump maximum pressure test 9
6.9 safety and environmental protection test 9
7 Inspection rules 10
7.1 Inspection classification 10
7.2 Test item 10
7.3 factory inspection 11
11 7.4 Inspection stereotypes
7.5 Periodic Inspection 12
8 Marking 13
13 8.1 General Requirements
8.2 Classification mark 13
8.3 Product nameplate 13
8.4 Operations with 13 flags
13 8.5 Safety Signs
8.6 Package Marking 13
9 packaging, transportation and storage 13
9.1 Packaging 13
9.2 Transport 14
9.3 Storage 14
10 accompanying documents 14
10.1 Technical Paper 14
10.2 Other documents 14
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard proposed by China Machinery Industry Federation.
The standard by the China Machinery Industry Federation.
Drafting of this standard. Hangzhou snow carbon thermostat Technology Co., Ltd., Chongqing Sida Test Equipment Co., Ltd., Zhejiang Branch metering
Studies Institute of Instrumentation Technology and Economy Institute, Southern Jiangsu Wuxi Test Equipment Co., Ministry of Electronics Industry and Information Technology
Fifth Institute, Hunan Academy of measuring and testing.
Participated in the drafting of this standard. the 海爱斯佩克 Environmental Equipment Co., Ltd., Shenyang Academy of Instrumentation Science, Anhui Institute of Metrology
Study hospital, instrument Hengyang Heng Electric Co., Ltd., China Electric Apparatus Research Institute, Shanghai Jing Hong Experimental Equipment Co., Ltd. Ningbo Dongfang heating equipment
Ltd., Chongqing Yinhe Experimental Instrument Co., Ltd.
The main drafters of this standard. Xu Yueming, Chen Yunsheng, Zhou Lianqin, Jinli Hui, Ni Yiming, Zousu Yang, Xiong Zhi-ming, Feng Hua, Xu Qiuling,
He Gang Jian, Liu Xiangheng, Zhouxiu Yuan, Li Yaqin, Wang Xiaofeng, Lim Chun Wing, Shen Zhong only, Jinmei Feng, Wang Jialong, Wang Huabin.
Thermostatic bath and circulating means
High temperature thermostat circulation means
1 Scope
This standard specifies the classification, conditions of high temperature thermostat cycle apparatus, requirements, test methods, inspection rules, marking, packaging, transportation, storage
Deposit and accompanying documents.
This standard applies to the high temperature thermostat cycle apparatus active cooling device is not equipped to provide liquid heat transfer medium in the form of a constant temperature environment (hereinafter
High temperature short cycle apparatus).
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 191-2008 Packaging - Pictorial signs
GB/T 2829-2002 periodic inspection Sampling procedures and tables (suitable for process stability test)
GB 4793.1-2007 measurement, control and laboratory safety requirements for electrical equipment - Part 1. General requirements
GB 4793.6-2008 measurement, control and laboratory safety requirements for electrical equipment - Part 6. Laboratory material heating apparatus
Particular requirements for equipment
GB/T 9969-2008 General Industrial Product Manual
GB/T 16895.10-2010 low-voltage electrical installations Part 4-44. Protection for safety voltage electromagnetic harassment and harassment protection
GB/T 17248.3-1999 Acoustics machinery and equipment noise emission and other operating position emission sound pressure levels specified location
Measuring method in situ
Determination of JB/T 9512-1999 climate chamber test equipment and sound power levels
Category 3
Non-combustible liquids or combustible liquids can be used as a high temperature liquid heat transfer medium circulation device, high temperature cycle device category names, requirements and standard
Chi Table 1.
Table 1
Category Name e liquid heat transfer medium request flag
Ⅰ a non-flammable liquid over-temperature protection c NFL
Combustible liquid b
Adjustable temperature over-temperature protection d
Adjustable temperature over-temperature protection and an additional level of protection d
FL
a usually water and the other in a single fault condition and the predetermined temperature range nonflammable liquid.
B liquid heat transfer medium flash point of not less than 65 ℃, Ⅱ class requirements apply, such as silicone oil. Otherwise Ⅲ class requirements apply, such as ethanol.
c independent, non-self-resetting, and can cut off all poles of the heater or level overtemperature protection device.
d can be adjusted over a moderate level of protection, it should only be carried out by means of tools.
e manufacturers the option of using or not using.
...