Path:
Home >
GB/T >
Page169 > GB/T 28852-2012
Price & Delivery
US$579.00 · In stock · Download in 9 secondsGB/T 28852-2012: Specifications for climatic chambers for biological applications
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 28852-2012 | English | 579 |
Add to Cart
|
5 days [Need to translate]
|
Specifications for climatic chambers for biological applications
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 28852-2012 (GB/T28852-2012) |
| Description (Translated English) | Specifications for climatic chambers for biological applications |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | N61 |
| Classification of International Standard | 19.040 |
| Word Count Estimation | 25,277 |
| Quoted Standard | GB/T 191-2008; GB/T 2829-2002; GB 4793.1-2007; GB 4793.6-2008; GB/T 9969-2008; GB/T 10586-2006; GB/T 11020-2005; GB/T 17248.3- 1999; JB/T 9512-1999 |
| Regulation (derived from) | National Standards Bulletin 2012 No. 28 |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard specifies the use of bio- artificial climate chamber conditions, requirements, test methods, inspection rules, marking, packaging, transport and storage. This standard applies to devices equipped with active cooling and (or) heating device, |
GB/T 28852-2012: Specifications for climatic chambers for biological applications
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Specifications for climatic chambers for biological applications
ICS 19.040
N61
National Standards of People's Republic of China
Bioartificial climatic test chambers
Issued on. 2012-11-05
2013-02-15 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 1 Conditions of Use
3.1 Environmental Conditions 1
3.2 Supply Condition 1
3.3 Water Supply 2
3.4 Load Condition 2
4 requires 2
4.1 appearance and structure 2
4.2 Technical Performance 2
4.3 Safety and environmental protection 3
Test Method 5 5
5.1 Main test instruments and equipment 5
5.2 Test conditions 6
5.3 various test points to determine the location and number 6
5.4 Temperature and humidity sensor light irradiation protection 8
5.5 Test appearance and structure 9
5.6 Operating temperature range Test 9
5.7 ACC operating temperature test 10
5.8 Temperature fluctuation test 10
5.9 Temperature uniformity test 11
5.10 Maximum humidification humidity and humidity fluctuation test 11
5.11 illuminance and photosynthetically active radiation intensity test 12
Cooling capacity test 12 5.12
5.13 Cooling time trial 13
5.14 Heating time trial 13
Safety and environmental protection test 13 5.15
15 6 Inspection Rules
6.1 Inspection classification 15
6.2 Test Item 15
6.3 factory inspection 16
16 6.4 Inspection stereotypes
6.5 Periodic Inspection 16
7 logo 18
7.1 General 18
7.2 Product nameplate 18
7.3 Operations with 18 flags
7.4 Safety signs 18
7.5 Package Marking 18
8 packaging, transportation and storage 19
8.1 Packaging 19
8.2 Transport 19
8.3 Storage 19
9 accompanying documents 19
9.1 Technical Document 19
9.2 Other documents 20
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard proposed by China Machinery Industry Federation.
The standard by the China Machinery Industry Federation.
This standard is drafted by. Hangzhou snow carbon thermostat Technology Co., Ltd. Chongqing four of test equipment, machinery and industrial equipment
Instrumentation Technology and Economy Institute, Southern Jiangsu Wuxi Test Equipment Co., Ltd., Anhui Institute of Metrology, the environment provided 海爱斯佩克
Preparation Limited, the Ministry of Industry and Information Technology Institute of Electronics V, Zhejiang Institute of Metrology.
Participated in the drafting of this standard. detection Hunan Institute of Metrology, Shanghai Jing Hong Experimental Equipment Co., Hengyang Heng Instrument Electric Co.
Limited Secretary, Shenyang Academy of Instrumentation Science, China Electric Apparatus Research Institute, Ningbo Dongfang Heating Equipment Co., Ltd., Chongqing Galaxy test equipment
the company.
The main drafters of this standard. Xu Yueming, Chen Yunsheng, Jinli Hui, Ni Yiming, Jinmei Feng, Feng Hua, Zousu Yang, Shen Zhong only bear to know that,
Li Yaqin, Liuxiang Heng, Xu Qiuling, Zhouxiu Yuan, Wang Xiaofeng, Wang Jialong, Lim Chun Wing, Zhoulian Qin, He Jian Gang, Wang Huabin.
Bioartificial climatic test chambers
1 Scope
This standard specifies the use of bio-artificial climate chamber conditions, requirements, test methods, inspection rules, marking, packaging, transport and
Storage.
This standard applies to devices equipped with active cooling and (or) heating means also has simulate human artificial light and (or) humidification devices
Work environment, biological experiments for the purpose of biological artificial climate chamber (hereinafter referred to as bio box).
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 191-2008 Packaging - Pictorial signs
GB/T 2829-2002 periodic inspection Sampling procedures and tables (suitable for process stability test)
GB 4793.1-2007 measurement, control and laboratory safety requirements for electrical equipment - Part 1. General requirements
GB 4793.6-2008 measurement, control and laboratory safety requirements for electrical equipment - Part 6. Laboratory material heating apparatus
Particular requirements for equipment
GB/T 9969-2008 General Industrial Product Manual
GB/T 10586-2006 humid chamber technical conditions
Listing flammability test method GB/T 11020-2005 solid non-metallic materials when exposed to flame sources
GB/T 17248.3-1999 Acoustics - Noise emitted by machinery and equipment and other operating positions specified position emission sound pressure levels measured
Volume method in situ
Determination of JB/T 9512-1999 climate chamber test equipment and sound power levels
3 Conditions of Use
3.1 Environmental conditions
Bio box should be under the following conditions.
a) indoor use;
b) a temperature of 5 ℃ ~ 35 ℃, no drastic changes in ambient temperature;
c) when the ambient temperature is below 31 ℃ maximum relative humidity of 80% and an ambient temperature of 35 ℃, the maximum relative humidity linear drop
To 67%;
d) altitude less than 2000m;
e) There should be no impact vibration around bio box use, the magnetic field (with the exception of the geomagnetic field), and other hot and cold radiation;
f) Pollution Level 2, around without high concentrations of dust or corrosive gases;
g) airflow around without a strong, strong demand when the ambient air flow, air flow should not be blown directly bio box cooling system and the air inlet door
around.
3.2 Supply conditions
Bio box power supply should meet the following conditions.
...