US$559.00 · In stock · Download in 9 secondsGB/T 28537-2012: Use and handling of sulphur hexafluoride (SF6) in high-voltage switchgear and controlgear
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 28537-2012 | English | 559 |
Add to Cart
|
5 days [Need to translate]
|
Use and handling of sulphur hexafluoride (SF6) in high-voltage switchgear and controlgear
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 28537-2012 (GB/T28537-2012) |
| Description (Translated English) | Use and handling of sulphur hexafluoride (SF6) in high-voltage switchgear and controlgear |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | K43 |
| Classification of International Standard | 29.130.10 |
| Word Count Estimation | 24,247 |
| Quoted Standard | GB 1984; GB/T 2900.20-1994; GB/T 8905; GB/T 11022-2011; GB/T 12022; GB/T 28534-2012 |
| Adopted Standard | IEC 62271-303-2008, MOD |
| Regulation (derived from) | National Standards Bulletin No. 13 of 2012 |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard applies to high-voltage switchgear and control equipment in the installation, transfer, normal and abnormal operation SF6 handling, disposal of end of life safety and environmental aspects of the procedure. These procedures should be conside |
GB/T 28537-2012: Use and handling of sulphur hexafluoride (SF6) in high-voltage switchgear and controlgear
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Use and handling of sulphur hexafluoride (SF6) in high-voltage switchgear and controlgear
ICS 29.130.10
K43
National Standards of People's Republic of China
High-voltage switchgear and control equipment for sulfur hexafluoride
(SF6) for use and handling
Useandhandlingofsulphurhexafluoride (SF6)
[IEC 62271-303.2008, High-voltageswitchgearandcontrolgear-
Part 303. Useandhandlingofsulphurhexafluoride (SF6), MOD]
Issued on. 2012-06-29
2012-11-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
Introduction Ⅳ
1 Scope 1
2 Normative references 1
3 Terms and definitions
SF6 handling during installation and transfer 4 4
4.1 Overview 4
Check the SF6 quality 4.2 evacuated, inflatable and inflatable 4
4.3 Prior compartment filled with SF6 is filled to the rated pressure/density of 5
Inflatable seal pressure system 4.4 5
SF6 handling 7 during the normal life of 5
Refilling 5.1 SF6 to the rated pressure/density 7
Check 5.2 SF6 quality 7
SF6 recycling and recovery of maintenance during 6 9
6.1 Overview 9
6.2 contains recovery not subject to arcing or subjected to normal and controllable arc SF6/and/or closed pressure system in all compartments of SF6
And recycling 10
6.3 contains subjected to severe arc SF6 controlled and/or closed pressure system in all compartments of SF6 recovery and recycling 11
Removing SF6 electrical equipment at the end of life 12 7
7.1 Overview 12
7.2 life controlled and/or closed end 13 of the pressure system
7.3 sealed pressure system life ended 13
7.4 at the end of life SF6 sealed pressure system of recovery and recycling 15
7.5 at the end of life of electrical equipment disassembly 16
7.6 byproduct end-of-life 17
References 18
Figure 1 SF6 inflatable compartments of the transfer and re-transfer of 4
2 pre-filled with SF6 compartment Fig inflated to the rated pressure/density 6
Figure 3 SF6 refilling to the rated pressure/density 7
Figure 4 on-site inspection SF6 quality 8
Figure 5 SF6 sampling and delivery 9
Figure 6 contains an arc not subject to recovery and/or subjected to normal arc SF6 controlled and/or closed pressure system in all compartments and SF6
Recycling 10
Figure 7 includes experienced severe arc SF6 controlled and/or closed pressure system in all compartments SF6 recovery and recycling 12
End of life 14 Figure 8 controlled and/or closed system pressure
9 ending 14 lifetime sealed pressure system
10 sealed pressure system at the end of life of SF6 recovery and recycling 15
Figure 11. Removing the power supply equipment 17
Table 1 SF6 inflatable compartments of the transfer and re-transfer of 5
Table 2 pre-filled with SF6 compartments inflated to the rated pressure/density 6
Table 3 SF6 refilling to the rated pressure/density 7
Table 4 on-site inspection SF6 quality 8
Table 5 SF6 sampling and delivery 9
Table 6 contains not subject to arcing and/or subjected to normal arc SF6 controlled and/or closed pressure system in all compartments and recovered SF6
Recycling 11
Table 7 contains serious arc SF6 through controlled and/or closed pressure system in all compartments of SF6 recovery and recycling 13
Table at the end of system life SF6 retraction pressure seal 8 16
Table 9 properties and expected SF6 byproducts number 17
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard uses redrafted law revision using IEC 62271-303.2008 "high-voltage switchgear and control equipment Part 303. Six
Sulfur hexafluoride (SF6) for use and handling. "
This standard and IEC 62271-303. 208 technical differences and their reasons are as follows.
--- Removed and this has nothing to do IEC 62271-303 standard in Chapter 4. SF6 storage and transportation, Chapter 5. Security and emergency services
Aid, Chapter 6. training and certification, Chapter 11. SF6 processing type of the device;
--- Delete this standard has nothing to do with the IEC 62271-303 Annex A (informative), Annex B (informative) Appendix C (informative)
And Annex D (informative) content.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the national high-voltage switch equipment Standardization Technical Committee (SAC/TC65) centralized.
This standard was drafted. Xi'an High Voltage Apparatus Research Institute Co., Ltd., Xi'an High Voltage Switch Co., Ltd., New Northeast Electric
Gas (Shenyang) High Voltage Switchgear Co., Ltd., Shanghai days Ling Switch Factory Co., Limited ABB (China) Co., Ltd., Beijing Northern Electric shares
Company, Jiangsu Province, such as high-pressure high Appliance Co., Ltd., Shanghai Electric Power Transmission Test Center Co., Ltd., Xiamen ABB High Voltage Switchgear Co.,
Secretary, Guangdong Fan Electric Equipment Manufacturing Co., Ltd., Shantou Zhengchao Electric Group Co., Ltd., Shenzhen Institute of Electrical Science, Ningbo Tianan set
Group benefits and Electric Group Co., Ltd., Zhejiang Switch Factory Co., Ltd., Henan high level of electrical Co., Ltd., Xi'an Electrical Switch
Ltd., Schneider Electric (China) Investment Co., Ltd. Taixing Branch Lide refrigeration equipment.
The main drafters of this standard. South Zhiyong, Xing Na, Wu Hongyan, Chen Zhibin, Huang Chao, Li Xinchun, Zhangcheng Bo, Sun Kuaigang, Xie Jianbo, Li Jinling,
Baby Lee, Lu-an, Shen Liang, Lin Fuming, Yang Kun, Shi Gang, Ningmao Liang, Guan Xing Yan, Shen Chun Ming Lei Xiaoqiang, Feng Xiaohong, Xiaomin Ying, Mo Kang,
Deng Yonghui.
Introduction
SF6 gas used in electrical switchgear and control equipment for over 30 years. It is mainly used for rated voltage above 1kV until the
There has manufactured the highest rated voltage switchgear and control equipment. It is estimated that there are several million units filled with different types of
SF6 units in operation.
According to GB/T 11022, there are three kinds of gas system is technically available.
--- Controllable pressure systems;
Note 1. Because unacceptable leak rate (see GB 7674), the new equipment is no longer controllable pressure systems.
--- Closed pressure systems. For the standard modern electrical equipment per year leak rate is 0.5% and 1% each inflatable compartments;
--- Sealed pressure system. For a modern medium voltage electrical equipment (commercially known as "lifelong seal products" or "hermetically sealed system"), the seal
Sealing pressure of the system to the provisions of its expected life. Leakage performance with respect to life expectancy by the manufacturer to regulate
set. Preferably of 20 years, 30 years and 40 years.
Note 2. In order to meet the anticipated requirements of life, that the annual rate of the leak sealed pressure system is less than 0.1%.
Electrical switching and control equipment used in the long-term experience has shown that SF6, as long as the establishment and comply with certain basic precautions and procedures
Order, to benefit the operation, safety and working environment, for example.
--- Safe operation of equipment;
--- Optimization of resources and tools;
--- Minimize equipment downtime of;
--- SF6 Processing Standards trainers;
--- Emissions during gas processing operation is reduced to below the limit of physical function;
--- Avoid any deliberate emissions, such as emissions into the atmosphere;
--- During the transfer, use, operation and end of life processing SF6 consumption and emissions to a minimum.
Recently, on the latest technology in SF6 switchgear and control practices recommended by the equipment has been studied by the committee CIGREB3
B3.02 Working Group will be published [1]. This information is used to develop this standard.
High-voltage switchgear and control equipment for sulfur hexafluoride
(SF6) for use and handling
1 Scope
This standard applies to high-voltage switchgear and control equipment SF6 processing installation, transfer, normal and abnormal operation, at the end of life
Procedures set of safety and the environment.
Should be considered in these procedures is to ensure the safety of personnel working SF6 and SF6 emissions will be the most minimal to the environment reduced the number of
Low demand.
This standard is generally applicable to a mixed gas of SF6.
Note 1. In order to facilitate the use of this standard, the voltage range of high-voltage switchgear in the usual sense generally refers to the rated voltage of 3.6kV and above. Practical application
The rated voltage range is typically medium voltage switchgear is 3.6kV ~ 63kV; Rated voltage range of high-voltage switchgear is 72.5kV ~
252kV; rated voltage range is EHV switchgear 363kV ~ 800kV; rated voltage range of special high-voltage switchgear is 1100kV
And above.
Note 2. The entire Standard, the term "electrical equipment" stands for "high-voltage and medium-voltage switchgear and/or control devices."
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 1984 high voltage AC circuit breaker (GB/T 1984-2003, IEC 62271-100, MOD)
GB/T 2900.20-1994 Electrotechnical terminology voltage switchgear (IEC 60050, NEQ)
GB/T 8905 sulfur hexafluoride gas in electrical equipment management and testing guidelines (GB/T 8905-1996, IEC 60480, NEQ)
GB/T 11022-2011 high-voltage switchgear and control equipment standard common technical requirements (IEC 62271-1.2007, MOD)
GB/T 12022 Industrial sulfur hexafluoride (GB/T 12022-2006, IEC 376, IEC 376A, IEC 376B, MOD)
GB/T 28534-2012 high-voltage switchgear and control equipment in sulfur hexafluoride (SF6) gas release impact on the environment and health
(IEC 62271-303.2008, MOD)
3 Terms and Definitions
GB/T 2900.20 define the following terms and definitions apply to this document.
Note. Many different types of switches and control equipment are used SF6 gas as insulation and/or arc-quenching medium.
3.1
Sulfur hexafluoride (SF6) abnormal release abnormalreleaseofsulphurhexafluoride (SF6)
Pressure system failures caused by the release of SF6 from a running device.
NOTE. abnormal release of SF6 is generally undesirable and continuous gas emissions. Just SF6 leak abnormality is detected, appropriate measures should be taken immediately set
Bit and reduce leakage.
3.2
Sulfur hexafluoride (SF6) processing handlingofsulphurhexafluoride (SF6)
Any process may involve the transfer of SF6.
...