US$599.00 · In stock · Download in 9 secondsGB/T 26870-2011: Industrial a.c. networks affected by harmonics - Application of filters and shunt capacitors
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 26870-2011 | English | 599 |
Add to Cart
|
5 days [Need to translate]
|
Industrial a.c. networks affected by harmonics - Application of filters and shunt capacitors
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 26870-2011 (GB/T26870-2011) |
| Description (Translated English) | Industrial a.c. networks affected by harmonics - Application of filters and shunt capacitors |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | K42 |
| Classification of International Standard | 31.060.70 |
| Word Count Estimation | 26,272 |
| Date of Issue | 2011-07-29 |
| Date of Implementation | 2011-12-01 |
| Quoted Standard | GB/T 14549-1993 |
| Adopted Standard | IEC 61642-1997, MOD |
| Regulation (derived from) | Announcement of Newly Approved National Standards No. 12 of 2011 |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard specifies the classical swine fever virus (Classical swine fever virus, CSFV) real-time fluorescent RT-PCR detection methods. This standard applies to classical swine fever in the diagnosis and monitoring of live pigs for their organs, blood, excrement, and cell culture CSFV nucleic acid detection. |
GB/T 26870-2011: Industrial a.c. networks affected by harmonics - Application of filters and shunt capacitors
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Industrial acnetworks affected by harmonics.Application of filters and shunt Capacitors
ICS 31.060.70
K42
National Standards of People's Republic of China
The filters and shunt capacitors are affected by harmonics
Application of Industrial AC Grid
(IEC 61642..1997, MOD)
2011-07-29 released
2011-12-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
China National Standardization Management Committee released
Directory
Preface III
1 Scope and Purpose 1
2 normative reference document 1
3 Terms and definitions 1
4 Overview 3
4.1 AC harmonics 3
4.2 reactive power 3
5 resonance problem and its solution 3
5.1 Introduction 3
5.2 Equivalent impedance diagram from the power supply side and equivalent impedance from the load bus
5.3 Example of Series Resonance 5
5.4 Parallel Resonance Example 7
5.5 Methods to prevent resonance 8
Parallel Capacitors and Filters for Power Systems
6.1 Introduction 12
6.2 Shunt capacitor 12
6.3 detuning filter
6.4 Tuning filter 13
6.5 Selection of equipment 13
6.6 Harmonized Capacitors and Filters for Audio Control Devices 14
Cascade Capacitors and Filters for Power System
7.1 Introduction 16
7.2 Specific requirements 16
7.3 Selection of reactive power compensation device 17
7.4 Type of filter 17
7.5 Selection of filter components
Interference between the shunt capacitor and the filter on the audio control device
Reference 20
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009 and GB/T 20000.2-2009.
This standard uses the re-drafting method to modify IEC 61642..1997 "filters and shunt capacitors in harmonic-affected industrial exchanges
Application in Power Grid "(English version).
The main technical differences between this standard and IEC 61642 are as follows.
--- in the "1.2 normative reference document" to increase GB/T 14549-1993 "power quality utility grid harmonics";
--- "" Capacitor for electric arc furnace "in" 1.1 Scope and Purpose "and" This standard does not apply to the following capacitors "
In the "4.4" filter type ", according to Chinese customary call, the" second-order filter --- band-pass filter "renamed" single-tuning
Filter "," second-order filter --- a resistive element damping filter "renamed" second-order high-pass filter. "
This standard is mainly related to IEC 61642 made the following editorial changes.
- The example calculation part of the original IEC standard is incorrect, has been modified, and a detailed example is calculated in the preparation note.
Description of the process and numerical changes.
This standard is proposed by China Electrical Equipment Industry Association.
This standard is under the jurisdiction of the National Power Capacitor Standardization Technical Committee (SAC/TC45).
The drafting unit of this standard. Shandong Taikai Power Electronics Co., Ltd., Xi'an Senbao Electrical Engineering Co., Ltd., Xi'an High Voltage Electric Research Institute
Limited liability company, Qingdao Hengshun Electric Co., Ltd., Anshan City Hengli Electric Equipment Manufacturing Co., Ltd., Guilin power capacitors have
Limited liability company, Hefei Warwick Automation Co., Ltd., Shenzhen Sanhe Electric Power Technology Co., Ltd., Anhui Electric Power Research Institute, Shenzhen
Central China Electric Power Technology Co., Ltd., Guangdong Power Grid Company Electric Power Research Institute, Shanghai Cooper Power Capacitor Co., Ltd., Anhui Ma'anshan City
Jin Ju filter complete sets of equipment Co., Ltd., Beijing China Si Electrical Technology Co., Ltd., Sichuan Bohong Power Filter Design Research Co., Ltd., Jiang
Jiangsu Province Jiangyin Mayor Group limited liability company.
The main drafters of this standard. Zhang Zongyou, Wang Heng, Liu Jing, Liang Chen, Jiang Junxiang, Zhang Jianfu, Fu Dazhi, Xu Baiyu, Yu Yang, Lv Tao,
Wang Linghai, Ding Chuanfa, Chen Si Cheng, Ping Xiao Xiang.
The filters and shunt capacitors are affected by harmonics
Application of Industrial AC Grid
1 scope and purpose
This standard gives guidance on the use of passive AC filters and shunt capacitors used to suppress harmonics and reactive power compensation in the industry.
See, including low pressure and high pressure. The proposed measures in this standard apply to harmonics of more than once to 25 (including 25).
This standard does not apply to the following capacitors.
Capacitor for induction heating devices [see GB/T 3984 (all parts)];
Series capacitors for power systems [see GB/T 6115 (all parts)];
Coupling capacitors and capacitive voltage dividers (see GB/T 19749);
Power electronic capacitors [see GB/T 17702 (all parts)];
AC motor capacitors [see GB/T 3667 (all parts)];
Tubular fluorescent lamps and other discharge lamp line capacitors (see GB 18489 and GB/T 18504);
A capacitor for suppressing radio interference;
A capacitor for use in various electrical equipment and as a component thereof;
And a capacitor used for superimposing an AC voltage having a DC voltage.
The purpose of this standard is to analyze the parallel capacitors and filters in the harmonic voltage and harmonic current affected by the industrial AC power grid in the conventional
Application of the problems, and give recommendations.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
Power quality - Harmonics of public power grid GB/T 14549-1993
3 terms and definitions
The following terms and definitions apply to this document.
3.1
Harmonic harmonic
The periodic communication is carried out to decompose the Fourier series to obtain an integer multiple of the fundamental frequency greater than 1.
[GB/T 14549-1993, definition 3.4]
3.2
Harmonic number
The ratio of the harmonic frequency fh to the fundamental frequency f1.
[GB/T 14549-1993, definition 3.5]
...