Path:
Home >
GB/T >
Page315 > GB/T 25753.3-2011
Price & Delivery
US$229.00 · In stock · Download in 9 secondsGB/T 25753.3-2011: Vacuum technology -- Roots vacuum pump -- Measurement of performance characteristics -- Part 3: Measurement of overflow valve differential pressure
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 25753.3-2011 | English | 419 |
Add to Cart
|
3 days [Need to translate]
|
Vacuum technology -- Roots vacuum pump -- Measurement of performance characteristics -- Part 3: Measurement of overflow valve differential pressure
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 25753.3-2011 (GB/T25753.3-2011) |
| Description (Translated English) | Vacuum technology -- Roots vacuum pump -- Measurement of performance characteristics -- Part 3: Measurement of overflow valve differential pressure |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | J78 |
| Classification of International Standard | 23.160 |
| Word Count Estimation | 10,145 |
| Date of Issue | 2011-11-21 |
| Date of Implementation | 2012-06-01 |
| Regulation (derived from) | Announcement of Newly Approved National Standards No. 18 of 2011 |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard specifies the Roots vacuum relief valve differential pressure measurement method. GB/T 25753 This part applies to pumping speed of 30 L/s ~ 20 000 L/s Roots vacuum pump (hereinafter referred to as the pump). This section does not apply to the performance of Roots vacuum pump ultimate pressure and pumping rate measurements. |
GB/T 25753.3-2011: Vacuum technology -- Roots vacuum pump -- Measurement of performance characteristics -- Part 3: Measurement of overflow valve differential pressure
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
.. Vacuum technology Roots vacuum pump Measurement of performance characteristics Part 3. Measurement of overflow valve differential pressure
ICS 23.160
J78
National Standards of People's Republic of China
Roots vacuum pumps - Measurement of performance art
Part 3. Measurement of differential pressure relief valve
characteristics-Part 3. Measurementofoverflowvalvedifferentialpressure
Issued on. 2011-11-21
2012-06-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
Introduction Ⅳ
1 Scope 1
2 Terms and definitions 1
3 apparatus 1
4 TEST CONDITIONS 4
Test Method 4 5
6 Test Results 4
7 Test Report 4
Foreword
GB/T 25753 "Roots vacuum pumps - Measurement of performance art" is divided into three parts.
--- Part 1. The maximum allowable differential pressure measurement;
--- Part 2. Zero flow compression ratio measurement;
--- Part 3. Measurement of differential pressure relief valve.
This is Part 3 GB/T 25753 of.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This part is proposed by China Machinery Industry Federation.
This part of the National Vacuum Technology Standardization Technical Committee (SAC/TC18) centralized.
This section is responsible for drafting. Zhejiang Vacuum Equipment Group Co., Ltd.
Participated in the drafting of this section. Chengdu South-ray machines Limited, Shenyang Institute of Scientific Instrument Development Center Co., Ltd., Shandong Zibo
Vacuum Equipment Co., Ltd., Shanghai Huifeng Petrochemical Co., Ltd., Taizhou Global Vacuum Equipment Manufacturing Co., Ltd., Shenyang Vacuum Technology Institute
The study.
The main drafters of this section. Wang Xi, Wang Xiaohu, Xu Tao, Fanlin Dong, Wang Guangyu, Xu Jian law, benefits Jinde Zhao meter spring, Zhao Weisheng,
Lingling, ROCKETS.
Introduction
With the development of basic industries and design innovation, design and performance Roots pump structure have made considerable
Progress early Roots vacuum pumps must rely on pre-pump operation, and now the development of a direct atmospheric discharge run-cooled Roots
Roots vacuum pumps and wet, the other a single series Roots vacuum pump has become the single-stage single-stage, two-stage, multi-stage, rotor profile also
Futaba become the double leaf, clover, leafy.
Existing Roots vacuum pump performance measure contains only a single-stage double-lobe Roots pump, other types not covered by the basic, and not
To regulate the pressure relief valve on the measurement method, in order to effectively improve the Roots vacuum pump performance measurement standards compatibility and applicability, the actual inspection
Experimental measurements provide the necessary operating instructions, from home and abroad in a wide range of relevant indicators, benchmarks, based on the actual situation, the development of the "vacuum technology
Roots vacuum pumps - Measurement of performance art "standard, to form a single sequence, and is divided into three parts. It will be based on the future status of technological development into
Line the necessary changes and expansion.
Roots vacuum pumps - Measurement of performance art
Part 3. Measurement of differential pressure relief valve
1 Scope
GB/T 25753 provisions of this part of the measurement methods Roots vacuum relief valve differential pressure.
GB/T 25753 apply to this part of the pumping speed of 30L/s ~ 20000L/s Roots vacuum pump (hereinafter referred to as the pump). This section does not
Roots vacuum pump is suitable for the performance of extreme pressure and pumping speed measurements.
2 Terms and definitions
The following terms and definitions apply to this document.
2.1
Pressure relief valve overflowvalvedifferentialpressure
Roots vacuum pump pressure relief valve is the difference between pre-stage pressure relief valve inlet pressure when carried off Movement.
2.2
Test cover testdome
Special vacuum vessel having a predetermined precise shape and dimensions, through which the gas to be measured into the pump, a pressure measuring means mounted thereon.
3 devices
3.1 Test cap
As shown in Figure 1, the shape of a cylinder. The axial dimension of the cover is 1.5D, D is the inner diameter of the housing. Test gas inlet is located in the axis of the cover
On the connection flange and the distance is D, arranged in the intake port should be such that the gas from the direction away from the pump into the test port cover. Measuring the inlet pressure
Gauge distance 0.5D connecting flange at its axis is perpendicular to the axis of the cover. Testing should cover the axis perpendicular to the pump inlet flange plane.
In addition to the intake line, the connecting line between the flange and the test covers the inner wall of the test should not wear a cap.
VD test cover volume should be at least one compression cycle pump swept five times the volume of the VP. In the pump inlet should be connected to a reducer fittings,
Its length should not exceed 0.5D (see Figure 1). Different specifications of the pump for test cover given in Table 1.
Table 1 Test parameters cover
VP/L VD/LD/mm
0 0.26 1.3 100
160 1.1 5.4 0.26 ~
1.1 ~ 4.2 21250
4.2 ~ 1784400
17 to 65 325 630
65 - 26013001000
260 to 106,053,001,600
1060 - 4060203002500
...