US$189.00 · In stock · Download in 9 secondsGB/T 25753.1-2010: Vacuum technology -- Roots vacuum pump -- Measurement of performance characteristics -- Part 1: Measurement of maximum tolerable differential pressure
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 25753.1-2010 | English | 339 |
Add to Cart
|
3 days [Need to translate]
|
Vacuum technology -- Roots vacuum pump -- Measurement of performance characteristics -- Part 1: Measurement of maximum tolerable differential pressure
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 25753.1-2010 (GB/T25753.1-2010) |
| Description (Translated English) | Vacuum technology -- Roots vacuum pump -- Measurement of performance characteristics -- Part 1: Measurement of maximum tolerable differential pressure |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | J78 |
| Classification of International Standard | 23.160 |
| Word Count Estimation | 8,860 |
| Date of Issue | 2010-12-23 |
| Date of Implementation | 2011-10-01 |
| Regulation (derived from) | National Standard Approval Announcement 2010 No.10 (Total No.165) |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard specifies the maximum allowable pressure Roots vacuum measurement speed. This section applies to pumping speed of 30 L/s-20 000 L/s Roots vacuum pump (hereinafter referred to as the pump). |
GB/T 25753.1-2010: Vacuum technology -- Roots vacuum pump -- Measurement of performance characteristics -- Part 1: Measurement of maximum tolerable differential pressure
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
.. Vacuum technology Roots vacuum pump Measurement of performance characteristics Part 1. Measurement of maximum tolerable differential pressure
ICS 23.160
J78
National Standards of People's Republic of China
Roots vacuum pumps - Measurement of performance art
Part 1. The maximum allowable differential pressure measurement
characteristics-Part 1. Measurementofmaximumtolerabledifferentialpressure
Issued on. 2010-12-23
2011-10-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 25753 "Roots vacuum pumps - Measurement of performance art" is divided into three parts.
--- Part 1 maximum allowable differential pressure measurement;
--- Part 2 compression ratio of zero flow measurement;
--- PART 3 relief valve differential pressure measurement.
This is Part 1 GB/T 25753 of.
This part is proposed by China Machinery Industry Federation.
This part of the National Vacuum Technology Standardization Technical Committee.
This section is responsible for drafting. Zhejiang Vacuum Equipment Group Co., Ltd.
Participated in the drafting of this section. Chengdu South-ray machines Limited, Shenyang Institute of Scientific Instrument Development Center, Shandong Zibo Vacuum Equipment
Co., Ltd., Anhui Hefei Science and Technology Co., Ltd., Shenyang Institute of Vacuum Technology.
The main drafters of this section. Wang Xiaohu, Wang Xi, Fanlin Dong, Wang Guangyu, Xu Jian law, Ms. Huang, Wang Lingling, ROCKETS.
Introduction
With the development of basic industries and design innovation, design and performance Roots pump structure have made considerable
Progress early Roots vacuum pumps must rely on pre-pump operation, and now the development of a direct atmospheric discharge run-cooled Roots
Roots vacuum pumps and wet, the other a single series Roots vacuum pump has become the single-stage single-stage, two-stage, multi-stage, rotor profile also
Futaba become the double leaf, clover, leafy.
Existing Roots vacuum pump performance measure encompasses only a single-stage double-lobe Roots pump, other types of basic not involved, and
Not made on how to measure the differential pressure relief valve specifications, to effectively improve the Roots vacuum pump performance measurement standards compatibility and suitability for the practical
Test measurements provide the necessary operating instructions, drawing in a wide range of domestic and foreign-related indicators, benchmarks, based on the actual situation, the development of the "vacuum
Roots vacuum pump performance measurement technology "standards, and is divided into three parts. Extreme pressure and pumping rate of the Roots vacuum pump unit
Energy measurements, not according to the standard content. In the future will make the necessary modifications and expansion basis of technological development.
Roots vacuum pumps - Measurement of performance art
Part 1. The maximum allowable differential pressure measurement
1 Scope
GB/T 25753 provisions of this part of the Roots vacuum pump the maximum allowable differential pressure measurement method.
This section applies to a pumping speed 30L/s ~ 20000L/s Roots vacuum pump (hereinafter referred to as the pump).
2 Terms and definitions
The following terms and definitions apply GB/T 25753 in this section.
2.1
The maximum allowable pressure maximumtolerabledifferentialpressure
The maximum allowable pressure refers to the continuous operation of the pump 1h, the maximum allowed by abnormal outlet pressure and the inlet pressure difference does not occur. for
Roots vacuum pump inlet pressure measurement should be equal to or slightly less than 1 × 103Pa.
Note. For other types of Roots vacuum pumps without inlet pressure value requirements, but should be appropriate for the structure of the pump, or follow the manufacturer's recommendations.
2.2
Test cover testdome
Special vacuum vessel having a predetermined precise shape and dimensions, through which the gas to be measured into the pump, on which pressure measurement
Means.
3 devices
3.1 Test cap
As shown in Figure 1, the shape of a cylinder. The axial dimension of the cover is 1.5D, D is the inner diameter of the housing. Test gas inlet is located in the axis of the cover
On the connection flange and the distance is D, arranged in the intake port should be such that the gas from the direction away from the pump into the test port cover. Measuring the inlet pressure
Gauge distance 0.5D connecting flange at its axis is perpendicular to the axis of the cover. Testing should cover the axis perpendicular to the pump inlet flange plane.
In addition to the intake line, the connecting line between the flange and the test covers the inner wall of the test should not wear a cap.
VD test cover volume should be at least one compression cycle pump swept five times the volume of the VP. In the pump inlet should be connected to a reducer fittings,
Its length should not exceed 0.5D (see Figure 1). Different specifications of the pump for test cover given in Table 1.
Table 1 Test parameters cover
VP/L VD/LD/mm
0 0.26 1.3 100
0.26 1.0 5.4 160
1.1 ~ 4.2 21250
4.2 ~ 1784400
17 to 65 325 630
65 - 26013001000
260 to 106,053,001,600
1060 - 4060203002500
...