GB/T 25091-2010 PDF English
Price & Delivery
US$419.00 · In stock · Download in 9 secondsGB/T 25091-2010: High-voltage direct-current disconnectors and earthing switches
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 25091-2010 | English | 419 | Add to Cart | 3 days [Need to translate] | High-voltage direct-current disconnectors and earthing switches |
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 25091-2010 (GB/T25091-2010) |
| Description (Translated English) | High-voltage direct-current disconnectors and earthing switches |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | K43 |
| Classification of International Standard | 29.130.10 |
| Word Count Estimation | 18,144 |
| Date of Issue | 2010-09-02 |
| Date of Implementation | 2011-02-01 |
| Quoted Standard | GB 1985-2004; GB/T 4585-2004; GB/T 11022-1999; GB/T 13498-2007; GB 13540-2009; GB/T 16927.1-1997; GB/T 20635-2006 |
| Regulation (derived from) | Announcement of Newly Approved National Standards No. 4 of 2010 (total 159) |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard specifies the high voltage DC disconnectors and earthing switches use conditions, ratings, design and construction, testing, equipment selection guidelines and other aspects of common technical requirements in order to harmonize the basic equipment design and test requirements to ensure safe operation of the system. This standard applies to the design and installation of indoor and outdoor, running on �� 800kv and below HVDC systems in isolation and earthing switches, This standard also applies to these disconnectors and earthing switch operating mechanism and auxiliary devices. |
GB/T 25091-2010: High-voltage direct-current disconnectors and earthing switches
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
High-voltage direct-current disconnectors and earthing switches ICS 29.130.10 K43 National Standards of People's Republic of China High voltage DC isolating switch and earthing switch 2010-09-02 release 2011-02-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China China National Standardization Management Committee released Directory Preface III 1 Overview 1 1.1 Scope 1 1.2 Normative references 1 2 normal and special conditions of use 1 3 Terms and definitions 1 4 rated 1 4.1 Rated DC voltage (Ur) 1 4.2 Rated insulation level 2 4.3 Rated current and temperature rise 2 4.4 Rated short time withstand current (Ik) 2 4.5 Rated peak withstand current (Ip) 2 4.6 Rated short duration (tk) 2 4.7 DC filter high voltage side of the isolation switch opening and closing DC filter capacity of the rated 2 4.8 DC filter high voltage side isolation switch electrical life 3 4.9 Rated contact area 3 4.10 Rated terminal mechanical load 3 4.11 Mechanical life rating 3 4.12 auxiliary power supply 3 4.13 Radio interference voltage level (RIV) 3 Structure Type 3 5.1 General 3 5.2 Flammability 3 5.3 creepage distance 3 5.4 Terminals 4 5.5 points, closing operation 4 5.6 operating mechanism 4 5.7 Protection class of enclosure 4 5.8 Interlock requirements 4 5.9 Mechanical strength 4 5.10 Reliability of location 4 5.11 auxiliary contact 4 5.12 ground 4 5.13 Seismic requirements 4 5.14 Electromagnetic compatibility 4 5.15 Nameplate 4 6 type test 4 6.1 Overview 4 6.2 Insulation test 5 6.3 Radio interference test 6 6.4 Main circuit resistance measurement 6 6.5 Temperature rise test 6 6.6 Short-time withstand current and peak withstand current test 6 6.7 Degree of protection test 7 6.8 Electromagnetic compatibility test (EMC) 7 6.9 Operation and mechanical life test 7 6.10 Operation under severe freezing conditions 7 6.11 Operation at extreme temperature 7 6.12 Seismic test 7 6.13 DC filter high voltage side isolation switch opening and closing harmonic current capability test 7 7 routine test 8 7.1 Insulation test of main circuit 8 7.2 Test of auxiliary circuit and control circuit 8 7.3 Main circuit resistance measurement 8 7.4 Mechanical Operation Test 8 7.5 Design inspection and visual inspection 8 8 field transfer test 8 8.1 Inspection after installation 8 8.2 Insulation resistance measurement 9 8.3 Insulation test for auxiliary and control circuits 8.4 Main circuit resistance measurement 9 8.5 check the dynamic, static contact between the distance 9 8.6 Operation agency test 9 8.7 porcelain flaw detection test 9 Guidance on the selection of DC disconnectors and earthing switches 9.1 Overview 9 9.2 Selection of ratings under normal operating conditions 9 10 Information provided with inquiries, tenders and orders 10.1 Information provided with inquiries and orders 10.2 Information provided with tenders 11 Rules for transport, storage, installation, operation and maintenance 11.1 Conditions for transport, storage and installation 12 11.2 Installation 12 11.3 running 12 11.4 Maintenance 12 12 security 12 12.1 Electrical aspects 12 12.2 Mechanical aspects 12 12.3 hot aspects 12 12.4 Operational aspects 12 Appendix A (informative) DC disconnector and earthing switch typical arrangement 13 Appendix B (informative) DC system overload current 14 B.1 Domestic ± 800kV DC system overload current 14 B.2 Domestic ± 500kV DC system overload current 14