Path:
Home >
GB/T >
Page272 > GB/T 15510-2008
Price & Delivery
US$329.00 · In stock · Download in 9 secondsGB/T 15510-2008: General rules for reliability test of electromagnetic relay for control circuits
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
GB/T 15510: Historical versions
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 15510-2008 | English | 329 |
Add to Cart
|
3 days [Need to translate]
|
General rules for reliability test of electromagnetic relay for control circuits
|
| GB/T 15510-1995 | English | 519 |
Add to Cart
|
4 days [Need to translate]
|
General rules for reliability test of electromagnetic relay for control circuits
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 15510-2008 (GB/T15510-2008) |
| Description (Translated English) | General rules for reliability test of electromagnetic relay for control circuits |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | K45 |
| Classification of International Standard | 29.120.50 |
| Word Count Estimation | 14,160 |
| Date of Issue | 2008-06-18 |
| Date of Implementation | 2009-03-01 |
| Older Standard (superseded by this standard) | GB/T 15510-1995 |
| Quoted Standard | GB/T 2423 (series); GB/T 14598.5-1993 |
| Regulation (derived from) | Announcement of Newly Approved National Standards No. 10 of 2008 (total 123) |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard specifies the control electromagnetic relay reliability test volume terms and their definitions and symbols, reliability index, test methods, classification and test reliability verification test procedures, test records and test reports. This standard applies to the product life can be reasonably considered to be exponentially distributed product reliability verification test. |
GB/T 15510-2008: General rules for reliability test of electromagnetic relay for control circuits
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
General rules for reliability test of electromagnetic relay for control circuits
ICS 29.120.50
K45
National Standards of People's Republic of China
Replacing GB/T 15510-1995
Electromagnetic relay for control rules for reliability test
Posted 2008-06-18
2009-03-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions, symbols 1
4 reliability index 3
5 Test Method 3
6 reliability verification test classification and test procedures 5
7 7 test records and test report
Appendix A (informative) Recommended relay reliability test control block diagram of the detection devices 9
Determination of Annex B (informative) grading test, test the upgrade and maintenance of test programs 10
Foreword
The standard in the preparation of the format and rules in line with GB/T 1.1-2000 "Standardization Guide Part 1. The structure and coding standards
Write Rules "requirements.
This standard replaces GB/T 15510-1995 "control electromagnetic relay rules for reliability test."
This standard and GB/T 15510-1995 compared to the main changes are as follows.
--- Increasing the sample extraction;
--- Increasing the detection of the box;
--- Increased screening test;
--- Deleted references.
The Standard Appendix A, Appendix B is an informative annex.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the National Standardization Technical Committee measure relays and protection equipment.
Drafting of this standard. National relay protection and automation equipment for Quality Supervision and Inspection Center, Hebei University, Xuchang relay
Institute of Xiamen Hongfa Electroacoustic Co., Ltd. People Electric Group Co., Ltd., Ningbo Forward Relay Co., XJ Electric Co., Limited
the company.
The main drafters of this standard. LU Jian-guo, Liquan Xi, Li Kui, Liu, Lu Ningyi high Bunraku, Dian Wang Rong, coke slope.
This standard replaces the standards previously issued as follows.
--- GB/T 15510-1995.
Electromagnetic relay for control rules for reliability test
1 Scope
This standard specifies the terms and their definitions, and control the amount of electromagnetic relay symbol reliability test, reliability, test methods,
Reliability Verification Test classification and test procedures, test records and test reports.
This standard applies to the product life it can reasonably be considered to be exponentially distributed product reliability verification tests.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 2423 (series) electric and electronic products environmental testing
GB/T 14598.5-1993 Electrical relays - Part 15. Electrical characteristics of relay contacts life testing of test equipment
(Idt IEC 60255-15. 1981)
3 Terms and definitions, symbols
3.1 Terms and Definitions
The following terms and definitions apply to this standard.
3.1.1
Electromechanical relay generates a predetermined response by the electromagnetic force.
3.1.2
Contact voltage drop
From the two terminals of a contact assembly measured voltage drop is closed between contacts.
3.1.3
Moment in a released state of the relay, under specified conditions, the amount of excitation applied at the input of the predetermined value until the instantaneous relay switch
Time interval between stopping.
3.1.4
On an operating state of the relay, under specified conditions, to produce a predetermined amount from the input stimulus change (this change will cause the relay to return
Only time instant back) until the moment the relay return interval.
3.1.5
Under specified conditions, it is applied to the relay, the relay can make an incentive amount of response.
3.1.6
Relay in the prescribed manner prescribed excited state.
...