Basic data
| Standard ID | GB/T 13035-2008 (GB/T13035-2008) |
| Description (Translated English) | Live working -- Insulating ropes |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | K47 |
| Classification of International Standard | 13.260; 29.035 |
| Word Count Estimation | 18,116 |
| Date of Issue | 2008-09-24 |
| Date of Implementation | 2009-08-01 |
| Older Standard (superseded by this standard) | GB/T 13035-2003 |
| Quoted Standard | GB/T 14286; GB/T 16927.1; DL/T 974 |
| Regulation (derived from) | Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall) |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard specifies the live working with insulating rope classification, materials, technical requirements, test methods, inspection rules, custody, storage and transportation. This standard applies to the AC and DC voltage level of the electrical equipment on the rope insulation material for live working. |
GB/T 13035-2008: Live working -- Insulating ropes
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Live working. Insulating ropes
ICS 13.260; 29.035
K47
National Standards of People's Republic of China
Replacing GB/T 13035-2003
Live working with insulating ropes
Posted 2008-09-24
2009-08-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Definitions 1
4 material 2
5 Classification and model specifications mark 2
6 2 Technical Requirements
7 Test Method 4
8 6 Inspection Rules
9 packaging, transportation and storage 8
Appendix A (normative) Power frequency dry flashover voltage test arrangement of Figure 9
Appendix B (normative) before moisture and damp-frequency leakage current test arrangement of FIG. 10
Annex C (normative) rain test layout 12
Annex D (normative) 13 glyph
Appendix E (normative) Guide 14
Foreword
This standard replaces GB/T 13035-2003 "live working with insulating rope."
The main difference compared with the standard GB/T 13035-2003 as follows.
--- Expand the scope of a close friend, a DC voltage level;
--- Modify the "breaking strength", "elongation" is defined in English;
--- The 'mechanical performance requirements "in the tension measurement requirements listed separately, an increase of Table 6;
--- Increase the basic requirements of "breaking strength and elongation test," the length of the specimen.
The Standard Appendix A, Appendix B, Appendix C, Appendix D, Appendix E are normative appendices.
The standard proposed by China Electricity Council.
This standard by the National Standardization Technical Committee work and live under the jurisdiction responsible for the interpretation.
This standard was drafted. State Grid Wuhan High Voltage Research Institute, Ltd. Ningbo days WONG electrical apparatus, Taizhou in Jiangsu Hongda insulation Equipment Factory.
The main drafters of this standard. Hu Yi, Wu Weining, Lvwei Hong, Jiang Da, Wang Yu, Gu Yong, Yi Hui, Zhang Lihua, Xu Ying.
This standard replaces the standards previously issued as follows.
--- GB/T 13035-1991; GB/T 13035-2003.
Live working with insulating ropes
1 Scope
This standard specifies the live working with insulating rope classification, materials, technical requirements, test methods, inspection rules, custody, storage and transport
Transport and so on.
This standard applies to the AC and DC voltage level of electrical equipment for live working insulating rope materials.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 14286 live working tools and equipment term (GB/T 14286-2008, IEC 60743.2001, MOD)
GB/T 16927.1 High-voltage test techniques Part 1. General test requirements (GB/T 16927.1-1997, eqv IEC
60060-1. 1989)
DL/T 974 live working tools warehouse
3 Definitions
GB/T 14286 and determined the following terms and definitions apply to this standard.
3.1
Measuring rope under tension circumscribed circle diameter.
3.2
The tension acting on the rope in the rope when the measured characteristics.
3.3
When the rope breakage measured maximum tension.
3.4
When the applied tensile force measurement tension value increased from 75% of rated breaking strength of the rope predetermined value, the rate of increase in the length of the rope.
3.5
It has good electrical insulating properties in a dry state or a rope made of natural fiber materials made of synthetic materials.
3.6
Materials made of natural fibers or synthetic fibers material, specially moisture treatment under high humidity conditions still have good electrical insulation
Can the ropes.
3.7
High-strength synthetic material, compared with the conventional strength of the insulating rope breaking strength increased more than 1 times the insulation ropes.
...