GB/T 12747.1-2017 PDF English
Price & Delivery
US$579.00 · In stock · Download in 9 secondsGB/T 12747.1-2017: Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V -- Part 1: General -- Performance, testing and rating -- Safety requirements -- Guide for installation and operation
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
GB/T 12747.1: Historical versions
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 12747.1-2017 | English | 579 | Add to Cart | 5 days [Need to translate] | Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V -- Part 1: General -- Performance, testing and rating -- Safety requirements -- Guide for installation and operation |
| GB/T 12747.1-2004 | English | 879 | Add to Cart | 4 days [Need to translate] | Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1000 V -- Part 1: General -- Performance, testing and rating -- Safety requirements -- Guide for installation and operation |
| GB/T 12747-1991 | English | 839 | Add to Cart | 6 days [Need to translate] | Low voltage shunt capacitors of the self-healing type |
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 12747.1-2017 (GB/T12747.1-2017) |
| Description (Translated English) | Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V -- Part 1: General -- Performance, testing and rating -- Safety requirements -- Guide for installation and operation |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | K42 |
| Classification of International Standard | 31.060.70 |
| Word Count Estimation | 29,281 |
| Date of Issue | 2017-07-31 |
| Date of Implementation | 2018-02-01 |
| Older Standard (superseded by this standard) | GB/T 12747.1-2004 |
| Quoted Standard | GB/T 5169.12-2013; GB/T 12747.2-2017; IEC 60060-1-2010; IEC 61000-2-2-2002; IEC 61000-4-1-2006 |
| Adopted Standard | IEC 60831-1-2014, IDT |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard is applicable to capacitor units and capacitor banks specifically designed to improve the power factor of a nominal voltage of 1 000 V and below, with a frequency of 15 Hz to 60 Hz AC power system. This standard also applies to capacitors used in power filter circuits. Additional definitions, requirements and tests for power filter capacitors are given in Appendix A. This standard does not apply to the following capacitors: 1. Nominal voltage 1 000 V and below AC power system with non-self-healing shunt capacitors; 2. Nominal voltage 1 000 V or more AC power system with a parallel capacitor; 3. At the frequency of 50 kH: Capacitor for induction heating device running below; 4. Series capacitor; 5. AC motor capacitor; 6. Coupling capacitor and capacitor |
GB/T 12747.1-2017: Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V -- Part 1: General -- Performance, testing and rating -- Safety requirements -- Guide for installation and operation
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Shunt power capacitors of the self-healing type for acsystems having a rated voltage up to and including 1 000 V. Part 1. General. Performance, testing and rating. Safety requirements. Guide for installation and operation ICS 31.060.70 K42 National Standards of People's Republic of China Replacing GB/T 12747.1-2004 Nominal voltage 1000V and below AC power System self-healing shunt capacitor Part 1. General performance, tests and quotas Safety Requirements Installation and Operational Guidelines voltageuptoandincluding1000V-Part 1.General-Performance, testingand (IEC 60831-1.2014, IDT) 2017-07-31Published.2018-02-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword V. 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 conditions of use 4 4.1 normal conditions of use 4 4.2 non-normal conditions of use 5 5 test requirements 5 5.1 Overview 5 5.2 Test conditions 5 6 test classification 5 6.1 Routine test 5 6.2 Type test 5 6.3 Acceptance test 6 Capacitance measurement and capacity calculation 7.1 Measurement Procedure 6 7.2 Capacitance deviation 6 Capacitor loss tangent (tan δ) measurement 8.1 Measurement Procedure 6 8.2 Capacitor loss tangent (tan δ) requirement 7 9-terminal voltage test 7 9.1 routine test 7 9.2 Type test 7 10 Terminal and shell voltage test 7 10.1 routine test 7 10.2 Type test 8 11 internal discharge device test 8 12 sealing test 8 13 Thermal stability test 8 Capacitor loss tangent (tan δ) measurement at high temperature 14.1 Measurement Procedure 9 14.2 Requirement 9 Test of lightning impulse voltage between terminal and housing Discharge test 10 17 Aging test 10 18 Self-healing test 10 19 Destruction test 10 20 The maximum allowable voltage of 10 20.1 Long-term voltage 10 20.2 Operating voltage 11 21 maximum allowable current 11 Discharge device safety requirements 11 23 shell connector safety requirements 12 Safety Requirements for Environmental Protection 12 Other safety requirements 12 26 capacitor unit logo 12 26.1 Nameplate 12 26.2 Standardized connection symbols 13 26.3 Warning Sign 13 27 capacitor bank logo 13 27.1 Manual or nameplate 13 27.2 Warning Sign 13 28 Overview of Installation and Operation Guideline 13 29 the choice of rated voltage 14 30 operating temperature 14 30.1 Overview 14 30.2 Installation 14 30.3 High Ambient Air Temperature 14 30.4 Loss Estimation 15 31 Special Conditions of Use 15 Over voltage 15 Overcurrent 16 34 switches, protection devices and connectors 16 35 choice of creepage distance 17 36 Capacitor connected to system with audio remote 17 Electromagnetic compatibility (EMC) 17 37.1 Radiation 17 37.2 Immunity 17 Appendix A (Normative) Power filter capacitors additional definitions, requirements and test 19 Appendix B (Informative) Capacitors and their devices formula 21 References 24 Figure B.1 Resistance and capacitor unit connection between the various values of k 23 Table 1 shows the upper end of the temperature range of the letter code 4 Table 2 Thermal stability of the ambient air temperature test 9 Table 3 Permitted voltage levels during operation 11