US$629.00 · In stock · Download in 9 secondsGA/T 914-2010: Forensic medical assessment of the hearing disorders
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedure
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GA/T 914-2010 | English | 629 |
Add to Cart
|
4 days [Need to translate]
|
Forensic medical assessment of the hearing disorders
|
Click to Preview a similar PDF
Basic data
| Standard ID | GA/T 914-2010 (GA/T914-2010) |
| Description (Translated English) | Forensic medical assessment of the hearing disorders |
| Sector / Industry | Public Security (Police) Industry Standard (Recommended) |
| Classification of Chinese Standard | A92 |
| Classification of International Standard | 13.310 |
| Word Count Estimation | 18,115 |
| Date of Issue | 2010-11-22 |
| Date of Implementation | 2010-12-01 |
| Quoted Standard | GB/T 4854.1; GB/T 7341.1-1998; GB/T 7582-2004; GB/T 7583-1987; GB 9706.1-2007; GB/T 15953-1995; GB/T 16403-1996 |
| Regulation (derived from) | Industry Standard Record Announcement No |
| Issuing agency(ies) | Ministry of Public Security |
| Summary | This standard specifies the basic principles, requirements, and methods of forensic assessment of hearing impairment. This standard applies to all kinds of hearing impairment and disability rating of the degree of forensic assessment, the other involved in the assessment of hearing impairment can also refer to the use. |
GA/T 914-2010: Forensic medical assessment of the hearing disorders
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Forensic medical assessment of the hearing disorders
ICS 13.310
A92
People's Republic of China Public Security Industry Standards
Forensic assessment hearing impaired
Issued on. 2010-11-22
2010-12-01 implementation
People's Republic of China Ministry of Public Security
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 1 General
5 different types of hearing impairment criteria 2
6 hearing impaired Evaluation Method 5
7 Annex 6
Appendix A (normative) Hearing Laboratory Practice 7
Annex B (informative) hearing impairment and causality judgment Severity Level 14
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
This standard by the National Standardization Technical Committee Technical Criminal forensic examination at the Technical Committee (SAC/TC179/SC6) proposed and
Centralized.
This standard was drafted. the Ministry of Justice of Forensic Science and Technology Institute.
The main drafters of this standard. Fan Lihua, Zhuguang You, Yang Xiaoping, late release Lu, Dong Daan, Li Xingqi.
Forensic assessment hearing impaired
1 Scope
This standard specifies the basic principles of hearing forensic assessment, requirements and methods.
This standard applies to all types of hearing damage and disability grade level forensic evaluation, the other relates to the hearing impaired can be assessed Senate
According to use.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 4854.1 acoustic calibration of audiometric equipment - Reference zero - Part 1. the ear headphones pure tone reference equivalent threshold sound pressure levels
GB/T 7341.1-1998 Audiometers - Part 1. pure tone audiometer
GB/T 7582-2004 Acoustics hearing thresholds and the statistical distribution of their age
GB/T 7583-1987 Acoustics pure tone air conduction audiometry hearing protection
GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety
GB/T 15953-1995 ear acoustic impedance/admittance measuring instrument
GB/T 16403-1996 Acoustics pure tone audiometry method air conduction and bone conduction threshold audiometry basic
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Hearing impairment hearingdisorders
Due to injury or disease and other causes of the structural integrity of the auditory system anatomical destruction or dysfunction, hearing loss occurs
Or lose.
3.2
Hearing threshold hearingthreshold
Under specified conditions, the subject of repeated trials can make the lowest sound pressure level of 50% correctly perceived.
3.3
Pure tone hearing level hearinglevel
At a predetermined frequency using a predetermined type of headphones and regulations to use the headset produces a predetermined acoustic coupling cavity or ear simulation
SPL pure tone and the corresponding reference equivalent threshold sound pressure level difference.
3.4
Hearing threshold level hearingthresholdlevel
At a predetermined frequency using a predetermined type of headphones, listening with a hearing threshold level representation.
4 General
4.1 Assessment Principles
4.1.1 should use clinical audiology and forensic theory and technology, combined with the practice of Forensic Sciences, a comprehensive analysis, comprehensive evaluation.
...