GA/T 1427-2017 PDF English

Std IDVersionUSDBuyDeliver [PDF] inTitle (Description)
GA/T 1427-2017English759 Add to Cart 4 days [Need to translate] Survey and data analysis methods for building fire loads

Click to Preview a similar PDF

Basic data

Standard ID GA/T 1427-2017 (GA/T1427-2017)
Description (Translated English) Survey and data analysis methods for building fire loads
Sector / Industry Public Security (Police) Industry Standard (Recommended)
Classification of Chinese Standard C80
Classification of International Standard 13.220.01
Word Count Estimation 18,181
Date of Issue 2017-09-07
Date of Implementation 2017-10-01
Issuing agency(ies) Ministry of Public Security

GA/T 1427-2017: Survey and data analysis methods for building fire loads


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Survey and data analysis methods for building fire ICS 13.220.01 C80 Public Safety Industry Standard of the People's Republic of China Building Fire Load Survey and Statistical Analysis Method Published on.2017-09-07 2017-10-01 implementation The Ministry of Public Security Directory Preface I Introduction II 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 General requirements for construction fire load investigation and statistical analysis methods 2 5 Sampling method of building fire load survey and determination of sample size 2 6 Procedures and Methods for Investigation of Building Combustibles 4 7 Statistical Analysis Method for Building Fire Loads 5 8 Fire Load Survey Report 7 Appendix A (Informative) Table 9 of Building Combustible Investigation Record Appendix B (Informative) Fire Load Investigation Report Example 10

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by the Ministry of Public Security Fire Department. This standard consists of National Fire Protection Standardization Technical Committee Construction Fire Safety Engineering Sub-Technical Committee (SAC/TC113/SC13) In the mouth. This standard is drafted by. Chinese People's Armed Police Force College. Participated in the drafting of this standard. Ministry of Public Security Fire Department, Ministry of Public Security Sichuan Fire Research Institute. The main drafters of this standard. Wu Lizhi, Gui Guicong, Guo Zidong, Li Yu'an, Lu Guojian, He Xuechao, Zhang Lou, Xu Fengqi, Ren Zeyu, Jiang Yuanyuan and Zhao Nan.

Introduction

This standard is based on the basic theory of statistical sampling survey and refers to the NFPA 557 of the American Fire Protection Association standard. The calculation method of the load, combined with the actual situation of the fire load investigation in China, can improve the investigation and statistical analysis of the building fire load. Scientific, normative and practical, providing fire load surveys for firefighting performance design and assessment, fire supervision and inspection, etc. Statistical analysis method. Building Fire Load Survey and Statistical Analysis Method

1 Scope

This standard specifies the sampling methods for building fire load surveys, sample size determination methods, construction combustibles investigation procedures and methods, and construction The statistical analysis method of fire load clarifies the main content that should be included in the investigation report. This standard applies to the investigation and statistical analysis of the building fire load.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. GB/T 3358.2-2009 Statistical vocabulary and symbols Part 2. Application statistics GB/T 5907.1-2014 Fire vocabulary - Part 1. General terms GB/T 10111-2008 Generation of Random Numbers and Its Application in Product Quality Sampling Inspection GB/T 14402-2007 Fire performance of combustion performance of building materials and products

3 Terms and Definitions

The terms and definitions defined in GB/T 10111-2008, GB/T 3358.2-2009, and GB/T 5907.1-2014 apply to This document. 3.1 Overall population The whole body of the fire load survey. Note. If a fire load survey is conducted on a city hotel, all hotels in the city are overall. 3.2 Unit unit The basic unit for conducting fire load investigations. Note. Such as standard rooms in hotel buildings, shops in shopping malls, offices in office buildings, etc. 3.3 Fixed combustible fixedcombustiblematerial The buildings themselves and the flammable materials in the buildings are basically unchanged. Note. Usually refers to the flammable materials used for the building materials and decoration materials used in the components such as walls, ceilings, floors, and doors, windows, fixed furniture, etc. Combustibles. 3.4 Mobile combustibles movecombustiblematerial In addition to the normal use of buildings, flammable materials that are additionally arranged, with a high variability in position and number, and that result from normal use Temporary combustibles. Note. Usually refers to various items placed in a building, such as goods in shopping malls, movable furniture in rooms, goods in warehouses, and books in libraries. 3.5 Fixed fire load fixedfireload The total amount of heat released by a fixed combustible within a unit of a building or building.
...