Home Cart Quotation Policy About-Us
www.ChineseStandard.net
Database: 221581 (27 Mar 2026)
SEARCH
Path: Home > MISC > Page101 > GA/T 1369-2016

GA/T 1369-2016 PDF English

Std IDVersionUSDBuyDeliver [PDF] inTitle (Description)
GA/T 1369-2016English879 Add to Cart 4 days [Need to translate] Guidance on fire risk assessment of assembly occupancies

Click to Preview a similar PDF

Basic data

Standard ID GA/T 1369-2016 (GA/T1369-2016)
Description (Translated English) Guidance on fire risk assessment of assembly occupancies
Sector / Industry Public Security (Police) Industry Standard (Recommended)
Classification of Chinese Standard C80
Classification of International Standard 13.220.99
Word Count Estimation 22,283
Date of Issue 2016-12-20
Date of Implementation 2017-03-01
Issuing agency(ies) Ministry of Public Security

GA/T 1369-2016: Guidance on fire risk assessment of assembly occupancies


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Guidance on fire risk assessment of assembly occupancies ICS 13.220.99 C80 People 's Republic of China Public Security Industry Standard Guidance on fire safety assessment of personnel - intensive places 2016-12-20 release 2017-03-01 implementation Issued by the Ministry of Public Security of the People 's Republic of China Directory Preface I 1 Scope 1 2 normative reference document 1 3 Terms and definitions 1

4 Evaluating working procedures and procedures

4.1 Overview 2 4.2 Pre-preparation 2 4.3 on-site inspection 2 4.4 Evaluation and judgment 4 4.5 Report preparation 4 Evaluation Unit and Evaluation 5.1 Fire safety management unit 5 5.2 Building fire protection unit 8 5.3 Safe evacuation facility unit 8 5.4 Fire Fighting Unit 9 Evaluation conclusion 7 Evaluation Report Format 11 7.1 Report Structure 11 7.2 Report Annex 11 Appendix A (informative) Field Inspection Record Table 12 Appendix B (informative) Questionnaire Example 13 Appendix C (Normative Appendix) Summary of Unit Unqualified Items Appendix D (normative) Summary of unit evaluation results Appendix E (Normative Appendix) Fire Safety Assessment Report Cover Format 16 Appendix F (Normative Appendix) Fire Safety Assessment Report Item Format 17 References 19

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard is proposed by the Ministry of Public Security Fire Department. This standard by the National Fire Safety Standardization Technical Committee Construction Fire Safety Engineering Subcommittee (SAC/TC113/SC13) Go back. This standard is responsible for the drafting unit. Ministry of Public Security Tianjin Fire Research Institute. This standard participates in the drafting unit. Fujian Public Security Fire Brigade, Tianjin Public Security Fire Brigade, Heilongjiang Provincial Public Security Fire Brigade, Shanghai Public Security Fire Corps, National Fire Engineering Technology Research Center. The main drafters of this standard. Zhang Yuxian, Wang Jie, Zhang Meihong, Wang Yiqi, Wang Da, Yan Jiawei, Jin Shunshun, Du Changhai, Zhao Huaoliang, Wang Xin, Zhang Xin, fruit Chunsheng, Ren Changxing. Guidance on fire safety assessment of personnel - intensive places

1 Scope

This standard specifies the working procedures and procedures, assessment units and assessment contents of the fire safety assessment of personnel-intensive places. Fire safety assessment Conclusions and fire safety assessment report requirements. This standard is applicable to the fire safety of personnel-intensive places (except labor-intensive enterprises in the production and processing workshops and employees' dormitories) Evaluation.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 5907 (all parts) Fire words Technical specification for fire detection of building fire protection facilities Fire safety management of personnel - intensive places

3 terms and definitions

GB/T 5907, GA 503, GA 654-2006 Definitions and the following terms and definitions apply to this document. For ease of use to Some of the terms and definitions in GA 654-2006 are repeated. 3.1 Public entertainment places publicentertainmentoccupancy With cultural and recreational, fitness and leisure functions and open to the public indoor places. Including theaters, video halls, auditoriums and other performances, screening , Dance hall, karaoke hall and other dance places, entertainment with the nightclub, music cafe, bars and dining venues, recreation, pleasure Places, bowling alley, roller skating rink, sauna and other entertainment, fitness, leisure venues and Internet access business premises and other places with the listed Functions of the same or similar business premises. Note. rewrite GA 654-2006, definition 3.1. 3.2 Public gathering place publicgatheringoccupancy Hotels, restaurants, shopping malls, bazaars, passenger station waiting room, ferry terminal waiting room, civil airport terminal, sports venues, halls to And public places of entertainment, as well as other places that are the same or similar to those listed. 3.3 Staff intensive place Public gathering place, hospital outpatient building, ward building, school teaching building, library, canteens and collective dormitory, nursing home, welfare homes, care Children's kindergarten, public library reading room, public exhibition hall, museum exhibition hall, labor-intensive enterprise production and processing workshop and Staff dormitories, tourism, religious venues and so on. Note. rewrite GA 654-2006, definition 3.2. 3.4 Check item checkitem Checklist entries set up for on-site inspection of evaluation contents of each evaluation unit.
...